MoS2/App/Modules/SicModules/PMs/Routines/PMToAtmIdleRoutine.cs

276 lines
11 KiB
C#
Raw Normal View History

2026-06-15 10:56:30 +08:00
using System.Collections.Generic;
using System.Diagnostics;
using Aitex.Core.RT.Device;
using Aitex.Core.RT.Device.Devices;
using Aitex.Core.RT.Event;
using Aitex.Core.RT.Routine;
using Aitex.Core.RT.SCCore;
using MECF.Framework.Common.Equipment;
using SicModules.PMs.Routines.Base;
namespace SicModules.PMs.Routines
{
public class PMToAtmIdleRoutine : PMBaseRoutine
{
private enum RoutineStep
{
RotationEnable,
HeatEnable,
VentPumpClose,
ArSupply,
SetGroupA,
SetGroupB,
SetGroupC,
SetGroupE,
SetGroupF,
SetGroupH,
SetGroupD,
SetGroupG,
SetGroupK,
SetMFCMode,
SetPCMode,
SetM1to16,
SetM17M18,
2026-08-15 10:36:59 +08:00
SetM18toM40,
2026-06-15 10:56:30 +08:00
SetPC,
SetM291519to38,
SetGroupJ,
SetM19to38,
SetGasOut,
SetTv,
SetGasIn1, //V68
OpenFinal1, //V91-96
SetMfcFinal1, //M32-38
SetMfc19to26,
SetTVCloseMode,
SetTvPositionToZero,
CheckPM1000,
SetGasIn2,
SetGroupJOpen,
SetM291519to26,
OpenFinal2,
SetMfcFinal2,
WaitPmPressureUp,
WaitPmPressureUp1,
SetEPV1,
SetEPV2,
SetTvMode,
SetEPVV1,
SetMfc28to40Special,
SetMfc28to40Default,
SetPC567Close,
SetPC567Mode,
SetPC567Default,
CheckFinal1Open,
SetV76,
SetV75,
SetV31,
SetV32,
SetV35V36,
SetV103,
SetV105,
2026-08-15 10:36:59 +08:00
SetGroupV25,
2026-06-15 10:56:30 +08:00
SetV92V93V95,
SetV94,
SetV96,
SetV68,
SetM32M35M37,
SetM36,
SetM38,
TimeDelay1,
TimeDelay2,
TimeDelay3,
TimeDelay4,
TimeDelay5,
TimeDelay6,
TimeDelay7,
TimeDelay8,
TimeDelay9,
TimeDelay10,
TimeDelay11,
TimeDelay18,
TimeDelay20,
TimeDelay21,
TimeDelay22,
Notify1,
}
private IoThrottleValve2 _IoThrottle;
private IoInterLock _pmIoInterLock;
private int _rotationCheckSpeed = 0; //设置旋转速度为0后检查是否转速低于此数值
private int _rotationCloseTimeout; //旋转停止超时
private int _IoValueOpenCloseTimeout = 10; //开关超时时间
private int _heatTimeOut = 5; //Heat关闭等待Di反馈超时时间
private int _waitPMPressureUpTimeout = 300; //等待反应腔压力到达1000的超时时间
private int _routineTimeOut;
private double _ventBasePressure;
private Stopwatch _swTimer = new Stopwatch();
public PMToAtmIdleRoutine(ModuleName module, PMModule pm) : base(module, pm)
{
Module = module.ToString();
Name = "AtmIdle";
_IoThrottle = DEVICE.GetDevice<IoThrottleValve2>($"{Module}.TV");
_pmIoInterLock = DEVICE.GetDevice<IoInterLock>($"{Module}.PMInterLock");
}
public override Result Start(params object[] objs)
{
Reset();
_rotationCloseTimeout = SC.GetValue<int>($"PM.{Module}.RotationCloseTimeout");
_routineTimeOut = SC.GetValue<int>($"PM.{Module}.Vent.RoutineTimeOut");
_ventBasePressure = SC.GetValue<double>($"PM.{Module}.Vent.VentBasePressure");
_waitPMPressureUpTimeout = SC.GetValue<int>($"PM.{Module}.Vent.VentTimeout");
if (!_pmIoInterLock.SetPMAtmIdleRountingRunning(true, out var reason))
{
EV.PostAlarmLog(Module, $"can not run ToATMIdle, {reason}");
return Result.FAIL;
}
currentPressureUpOrDown = PressureUpOrDown.None;
_swTimer.Restart();
_finalOpen = false;
Notify("Start");
return Result.RUN;
}
public override Result Monitor()
{
try
{
CheckRoutineTimeOut();
2026-08-15 10:36:59 +08:00
//DOR Pump 抽真空。关闭V76,打开V75
2026-06-15 10:56:30 +08:00
SetIoValueByGroup((int)RoutineStep.SetV76, IoGroupName.V76, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetV75, IoGroupName.V75, true, _IoValueOpenCloseTimeout);
//旋转停止,加热停止
SetHeatEnable((int)RoutineStep.HeatEnable, false, _heatTimeOut);
SetRotationValve((int)RoutineStep.RotationEnable, _rotationCheckSpeed, false, _rotationCloseTimeout);
//关闭V72,打开V25
SetIoValueByGroup((int)RoutineStep.VentPumpClose, IoGroupName.VentPump, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupV25, IoGroupName.V25, true, _IoValueOpenCloseTimeout);
//打开V31,打开V32
SetIoValueByGroup((int)RoutineStep.SetV31, IoGroupName.V31, true, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetV32, IoGroupName.V32, true, _IoValueOpenCloseTimeout);
2026-08-15 10:36:59 +08:00
//5、 打开 V35(H2N2.Line1)、 V36H2N2.Line2 , 关闭 B/ C / E / F / H / K Valves,打开 D/ G Valves 。
2026-06-15 10:56:30 +08:00
SetIoValueByGroup((int)RoutineStep.SetV35V36, IoGroupName.V35V36, true, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupB, IoGroupName.B, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupC, IoGroupName.C, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupE, IoGroupName.E, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupF, IoGroupName.F, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupH, IoGroupName.H, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupK, IoGroupName.K, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupD, IoGroupName.D, true, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupG, IoGroupName.G, true, _IoValueOpenCloseTimeout);
2026-08-15 10:36:59 +08:00
//6、 M1-M17 设定为 default 值, 所有 PC 设定为 default 值PC1-PC9 M18 - M40除 M30\M34\M39 MFC 5s ramp 到 0。
2026-08-19 14:26:19 +08:00
SetMfcModeToNormalByGroup((int)RoutineStep.SetMFCMode, MfcGroupName.All);
2026-06-15 10:56:30 +08:00
SetPcToDefault((int)RoutineStep.SetPC, _lstPcList);
2026-08-15 10:36:59 +08:00
SetMfcToDefaultByGroup((int)RoutineStep.SetM18toM40, MfcGroupName.M18toM40No303439, 5);
2026-06-15 10:56:30 +08:00
2026-08-15 10:36:59 +08:00
//7、 关闭蝶阀, 再关闭 EPV2
2026-06-15 10:56:30 +08:00
SetThrottleToCloseMode((int)RoutineStep.SetTVCloseMode, _IoThrottle, 8);
SetThrottleDisable((int)RoutineStep.SetTvPositionToZero, _IoThrottle, 8);
TimeDelay((int)RoutineStep.TimeDelay1, 1);
SetIoValueByGroup((int)RoutineStep.SetEPV2, IoGroupName.EPV2, false, _IoValueOpenCloseTimeout);
2026-08-15 10:36:59 +08:00
//8、 打开 A ValvesV33S(SH.H2/N2 Switch); V67、 V68(N2.Supply ).
2026-06-15 10:56:30 +08:00
SetIoValueByGroup((int)RoutineStep.SetGroupA, IoGroupName.A, true, _IoValueOpenCloseTimeout);
2026-08-15 10:36:59 +08:00
//9 、 打 开 V87 SHPurge.Final )、 V88 OuterGas.Final )、 V89 InnerGas.Final )、 V90MiddleGas.Final 、 V91OpticPurge.Final、 V97CarryGas.Final
//M27、 M28、 M29、 M31、 M33、 M40 依次设定 3S ramp 到 default 值
2026-06-15 10:56:30 +08:00
SetIoValueByGroup((int)RoutineStep.OpenFinal2, IoGroupName.Final2, true, _IoValueOpenCloseTimeout);
SetMfcToDefaultByGroup((int)RoutineStep.SetMfcFinal2, MfcGroupName.Final2, 3);
2026-08-15 10:36:59 +08:00
//10、 打开 V92GasRingPurge.Final、 V93ChamberPurge.Final、 V95ConfinementRing.Final等待 3S
2026-06-15 10:56:30 +08:00
SetIoValueByGroup((int)RoutineStep.SetV92V93V95, IoGroupName.V92V93V95, true, _IoValueOpenCloseTimeout);
TimeDelay((int)RoutineStep.TimeDelay2, 3);
2026-08-15 10:36:59 +08:00
//11、 M32、 M35、 M37 依次设定 3S ramp 到 default 值 等待 3S
2026-06-15 10:56:30 +08:00
SetMfcToDefaultByGroup((int)RoutineStep.SetM32M35M37, MfcGroupName.M32M35M37, 3);
2026-08-15 10:36:59 +08:00
//12、 打开 J Valves ;设置 M18-M26 3s ramp 到 default 值。
//等到腔体压力达到 900 mbar打开 V94RotationUpPurge.Final、 M36 设定 5S ramp 到 default 值;
//等待 3S打开 V96HeaterWF.Final M38 设定 5S ramp 到 default 值;
2026-06-15 10:56:30 +08:00
SetIoValueByGroup((int)RoutineStep.SetGroupJOpen, IoGroupName.J, true, _IoValueOpenCloseTimeout);
2026-08-15 10:36:59 +08:00
WaitPMPressureAndSetMfcSpecial((int)RoutineStep.WaitPmPressureUp1, 900, _waitPMPressureUpTimeout);
2026-06-15 10:56:30 +08:00
SetIoValueByGroup((int)RoutineStep.SetV94, IoGroupName.V94, true, _IoValueOpenCloseTimeout);
SetMfcToDefaultByGroup((int)RoutineStep.SetM36, MfcGroupName.M36, 5);
TimeDelay((int)RoutineStep.TimeDelay3, 3);
SetIoValueByGroup((int)RoutineStep.SetV96, IoGroupName.V96, true, _IoValueOpenCloseTimeout);
SetMfcToDefaultByGroup((int)RoutineStep.SetM38, MfcGroupName.M38, 5);
2026-08-15 10:36:59 +08:00
//13、 压力达到 1020结束
2026-06-15 10:56:30 +08:00
NotifyInfo((int)RoutineStep.Notify1, $"Wait pm pressure to {_ventBasePressure} mbar!");
2026-08-15 10:36:59 +08:00
WaitPMPressureAndSetMfcSpecial((int)RoutineStep.WaitPmPressureUp, _ventBasePressure, _waitPMPressureUpTimeout); //等待反应腔压力大于1000
2026-06-15 10:56:30 +08:00
}
catch (RoutineBreakException)
{
return Result.RUN;
}
catch (RoutineFaildException)
{
return Result.FAIL;
}
_pmIoInterLock.SetPMAtmIdleRountingRunning(false, out var reason);
Notify($"Finished ! Elapsed time: {(int)(_swTimer.ElapsedMilliseconds / 1000)} s");
_swTimer.Stop();
return Result.DONE;
}
public override void Abort()
{
_pmIoInterLock.SetPMAtmIdleRountingRunning(false, out var reason);
_pmIoInterLock.SetPMVentRoutineRunning(false, out _);
PmDevice._ioThrottleValve.StopRamp();
PmDevice.SetMfcStopRamp(PmDevice.GetMfcListByGroupName(MfcGroupName.All));
PmDevice.SetRotationServo(0, 0);
base.Abort();
}
private void CheckRoutineTimeOut()
{
if (_routineTimeOut > 10)
{
if ((int)(_swTimer.ElapsedMilliseconds / 1000) > _routineTimeOut)
{
EV.PostAlarmLog(Module, $"Routine TimeOut! over {_routineTimeOut} s");
throw (new RoutineFaildException());
}
}
}
}
}