using System ;
using System.Collections.Generic ;
using System.Xml ;
using Aitex.Core.Common.DeviceData ;
using Aitex.Core.RT.DataCenter ;
using Aitex.Core.RT.Event ;
using Aitex.Core.RT.IOCore ;
using Aitex.Core.RT.Log ;
using Aitex.Core.RT.OperationCenter ;
using Aitex.Core.RT.SCCore ;
using Aitex.Core.Util ;
namespace Aitex.Core.RT.Device.Devices
{
public interface IValve
{
bool TurnValve ( bool isOn , out string reason );
}
public class IoValve : BaseDevice , IDevice , IValve
{
#region Variables
private readonly DeviceTimer _timMfcRampTimeout = new DeviceTimer ();
private const int MFC_RAMP_DURATION_SEC = 5 ;
private const int MFC_RAMP_TIMEOUT_SEC = 10 ;
private readonly object _mfcLock = new object ();
private IoMFC _mappedMfc ;
private bool _isValveOnAfterMfcRamp ;
#endregion
public string GVName { get { return Name ; } }
public string GVDeviceID { get { return DeviceID ; } }
public bool GVIsDefaultOpen { get { return _isDefaultOpen ; } }
public Func < bool , bool > FuncCheckInterLock ;
public Func < bool , bool > FuncForceOpen ;
public Action < bool > ActionAfterOnOff ; //作用于EPV1和EPV2
[Subscription(AITValveDataPropertyName.SetPoint)]
public bool SetPoint //True: open| False: close
{
get
{
if ( _doOpen == null )
return false ;
return _isNc ? _doOpen . Value : ! _doOpen . Value ;
}
set
{
if ( _doOpen != null )
{
_doOpen . Value = _isNc ? value : ! value ;
}
if ( _doClose != null )
{
_doClose . Value = _isNc ? ! value : value ;
}
}
}
[Subscription(AITValveDataPropertyName.Status)]
public bool Status //True: open | False: close
{
get
{
if ( _diOpenSensor != null && _diCloseSensor != null )
return _diOpenSensor . Value && ! _diCloseSensor . Value ;
if ( _diCloseSensor != null )
return ! _diCloseSensor . Value ;
if ( _diOpen != null )
return _isNc ? _diOpen . Value : ! _diOpen . Value ;
if ( _doOpen != null )
return _isNc ? _doOpen . Value : ! _doOpen . Value ;
if ( _doClose != null )
return _isNc ? ! _doClose . Value : _doClose . Value ;
return false ;
}
}
private AITValveData DeviceData
{
get
{
AITValveData data = new AITValveData ()
{
UniqueName = _uniqueName ,
DeviceName = GVName ,
DefaultValue = GVIsDefaultOpen ,
DeviceSchematicId = DeviceID ,
DisplayName = Display ,
Feedback = Status ,
SetPoint = SetPoint ,
};
return data ;
}
}
/// <summary>
/// normal closed, 0 关闭,1打开
/// </summary>
public bool _isNc ;
/// <summary>
/// default open
/// </summary>
public bool _isDefaultOpen ;
private DIAccessor _diOpenSensor ;
private DIAccessor _diCloseSensor ;
private DIAccessor _diOpen ;
private DOAccessor _doOpen ;
private DOAccessor _doClose ;
private bool _operation ;
R_TRIG forceOpenTrigger = new R_TRIG ();
R_TRIG eventTrigger = new R_TRIG ();
R_TRIG _mutexSignalTrigger = new R_TRIG ();
DeviceTimer _timer = new DeviceTimer ();
DeviceTimer _mutexSignalTimer = new DeviceTimer ();
private bool _scBypassEnableTable ;
private string _uniqueName ;
public IoValve ( string module , XmlElement node , string ioModule = "" ) : base ( module , node , ioModule )
{
//var attrModule = node.GetAttribute("module");
//base.Module = string.IsNullOrEmpty(attrModule) ? module : attrModule;
//base.Name = node.GetAttribute("id");
//base.Display = node.GetAttribute("display");
//base.DeviceID = node.GetAttribute("schematicId");
_isNc = GetValue ( node , "isNc" ); // Convert.ToBoolean(node.GetAttribute("isNc"));
_isDefaultOpen = GetValue ( node , "isDefaultOpen" ); // Convert.ToBoolean(node.GetAttribute("isDefaultOpen"));
_diOpenSensor = ParseDiNode ( "diOpenSensor" , node , ioModule );
_diCloseSensor = ParseDiNode ( "diCloseSensor" , node , ioModule );
_doOpen = ParseDoNode ( "doOpen" , node , ioModule );
_diOpen = ParseDiNode ( "diOpen" , node , ioModule );
_doClose = ParseDoNode ( "doClose" , node , ioModule );
_uniqueName = $"{Module}.{Name}" ;
string path ;
2026-08-27 16:11:42 +08:00
if ( ioModule . StartsWith ( "PM" ))
path = $"PM.{ioModule}.BypassEnableTable" ; //_scBypassEnableTable = ParseScNode("scBypassEnableTable", node, module, $"PM.{module}.BypassEnableTable");
2026-06-15 10:56:30 +08:00
else
2026-08-27 16:11:42 +08:00
path = $"{ioModule}.BypassEnableTable" ; //_scBypassEnableTable = ParseScNode("scBypassEnableTable", node, module, $"{module}.BypassEnableTable");
2026-06-15 10:56:30 +08:00
_scBypassEnableTable = SC . SafeGetValue ( path , false );
SC . RegisterValueChangedCallback ( path , obj => _scBypassEnableTable = ( bool ) obj );
}
private bool GetValue ( XmlElement node , string xmlNodeName )
{
var xmlNodeValue = node . GetAttribute ( xmlNodeName );
return string . IsNullOrEmpty ( xmlNodeValue )? SC . GetValue < bool >( $"{ScBasePath}.{Name}.{xmlNodeName}" ) : Convert . ToBoolean ( xmlNodeValue );
}
public bool Initialize ()
{
DATA . Subscribe ( $"Device.{Module}.{GVName}" , () => DeviceData );
DATA . Subscribe ( $"{_uniqueName}.DeviceData" , () => DeviceData );
DATA . Subscribe ( $"{_uniqueName}.Status" , () => Status );
OP . Subscribe ( $"{_uniqueName}.{AITValveOperation.GVTurnValve}" , InvokeOpenCloseValve );
DEVICE . Register ( String . Format ( "{0}.{1}" , Name , AITValveOperation . GVTurnValve ), ( out string reason , int time , object [] param ) =>
{
bool bOn = Convert . ToBoolean (( string ) param [ 0 ]);
bool ret = TurnValve ( bOn , out reason );
if ( ret )
{
reason = string . Format ( "Valve {0}{1}" , Name , bOn ? "Open" : "Close" );
return true ;
}
return false ;
});
//for recipe
DEVICE . Register ( String . Format ( "{0}" , Name ), ( out string reason , int time , object [] param ) =>
{
bool bOn = Convert . ToBoolean (( string ) param [ 0 ]);
bool ret = TurnValve ( bOn , out reason );
if ( ret )
{
reason = string . Format ( "Valve {0}{1}" , Name , bOn ? "Open" : "Close" );
return true ;
}
return false ;
});
return true ;
}
public void Terminate ()
{
string reason ;
lock ( _mfcLock )
{
if ( _mappedMfc != null )
{
_mappedMfc . StopRamp ();
_mappedMfc = null ;
_timMfcRampTimeout . Stop ();
}
}
TurnValve ( _isDefaultOpen , out reason );
}
private bool InvokeOpenCloseValve ( string method , object [] args )
{
string reason ;
bool op = Convert . ToBoolean ( args [ 0 ]);
string name = op ? "Open" : "Close" ;
if (! TurnValve ( op , out reason ))
{
EV . PostWarningLog ( Module , $"Can not {name} valve {Module}.{Name}, {reason}" );
return false ;
}
EV . PostInfoLog ( Module , $"{name} valve {Module}.{Name}" );
return true ;
}
protected override void HandleMonitor ()
{
try
{
if ( _diOpenSensor != null && _diCloseSensor != null )
{
if ( _diOpenSensor . Value != _diCloseSensor . Value )
{
_mutexSignalTimer . Start ( 2000 );
}
_mutexSignalTrigger . CLK = _mutexSignalTimer . IsTimeout ();
if ( _mutexSignalTrigger . Q )
{
EV . PostWarningLog ( Module , $"Valve {Name} was abnormal, Reason: diOpenSensor's value is {_diOpenSensor.Value} and diCloseSensor's value is {_diCloseSensor.Value} too." );
}
}
MonitorMfc ();
if ( _timer . IsTimeout ())
{
forceOpenTrigger . RST = true ;
_timer . Stop ();
if ( Status != _operation )
{
if ( _operation )
{
string reason ;
if (! _doOpen . Check ( _isNc ? true : false , out reason ))
EV . PostMessage ( Module , EventEnum . ValveOperationFail , Module , Display , "Open" , ": Failed for interlock " + reason );
else
EV . PostMessage ( Module , EventEnum . ValveOperationFail , Module , Display , "Open" , ": Valve keep closed " );
}
else
{
string reason ;
if (! _doOpen . Check ( _isNc ? true : false , out reason ))
EV . PostMessage ( Module , EventEnum . ValveOperationFail , Module , Display , "Close" , ": Failed for interlock " + reason );
else
EV . PostMessage ( Module , EventEnum . ValveOperationFail , Module , Display , "Close" , ": Valve keep open" );
}
}
else if ( ActionAfterOnOff != null )
{
ActionAfterOnOff ( Status );
}
_operation = SetPoint ;
}
else if ( _timer . IsIdle ())
{
eventTrigger . CLK = SetPoint != _operation ; // fire event only check at first, SetPoint set by interlock
if ( eventTrigger . Q )
{
if ( _operation )
{
string reason ;
if (! _doOpen . Check ( _isNc ? true : false , out reason ))
EV . PostMessage ( Module , EventEnum . SwInterlock , Module , string . Format ( "Valve {0} was {1}, Reason: {2}" , Display , "Close" , reason ));
else
EV . PostMessage ( Module , EventEnum . SwInterlock , Module , string . Format ( "Valve {0} was {1}, Reason {2}" , Display , "Close" , "PLC kept" ));
}
else
{
string reason ;
if (! _doOpen . Check ( _isNc ? true : false , out reason ))
EV . PostMessage ( Module , EventEnum . SwInterlock , Module , string . Format ( "Valve {0} was {1}, Reason: {2}" , Display , "Open" , reason ));
else
EV . PostMessage ( Module , EventEnum . SwInterlock , Module , string . Format ( "Valve {0} was {1}, Reason {2}" , Display , "Open" , "PLC Kept" ));
}
_operation = SetPoint ;
}
}
//达到一定条件,强制打开阀门
if ( FuncForceOpen != null && ! _scBypassEnableTable )
{
forceOpenTrigger . CLK = FuncForceOpen ( Status );
if ( forceOpenTrigger . Q )
{
SetPoint = ! Status ;
EV . PostMessage ( Module , EventEnum . SwInterlock , Module , $"Force Set {Name} to {!Status} for Interlock enable table!" );
}
}
}
catch ( Exception ex )
{
LOG . Write ( ex );
}
}
public bool TurnValve ( bool isOn , out string reason )
{
reason = "" ;
bool bValue = _isNc ? isOn : ! isOn ;
// 如果要打开阀门,并且阀门已经在打开状态,则啥也不干
if ( isOn && Status )
{
return true ;
}
_timer . Stop ();
if ( _doOpen != null )
{
if (! _doOpen . Check ( bValue , out reason ))
{
EV . PostWarningLog ( Module , $"Turn {Display} {ValveStateToString(isOn)} failed for Interlock!" );
EV . PostMessage ( Module , EventEnum . SwInterlock , Module , string . Format ( "Valve {0} was {1}, Reason: {2}" , Display , "Open" , reason ));
return false ;
}
if ( FuncCheckInterLock != null && ! _scBypassEnableTable )
{
if (! FuncCheckInterLock ( isOn ))
{
reason = "Interlock check failed!" ;
//EV.PostWarningLog(Module, $"Turn {Display} {ValveStateToString(isOn)} failed for check condition!");
return false ;
}
}
}
if ( _doClose != null )
{
if (! _doClose . Check (! bValue , out reason ))
{
EV . PostMessage ( Module , EventEnum . SwInterlock , Module , string . Format ( "Valve {0} was {1}, Reason: {2}" , Display , "Close" , reason ));
return false ;
}
}
if ( ValveToMFCMap . ValveControlMFC . TryGetValue ( Name , out var _mfcName )) // 需要Ramp前置MFC
{
if (! isOn ) //关闭蝶阀时,关闭MFC,如果MFC为0时可以不用设置,但是没有获取MFC当前状态的函数,
{
if ( _doOpen . Value ) //气阀是开启状态了,需要关闭MFC,
{
CloseMFC ( isOn , _mfcName );
return true ;
}
}
else //这是开阀指令,开阀时如果阀门时关闭状态,MFC设置为零,保证气流平缓
{
if ( Name != "TMVent" && ! _doOpen . Value ) //气阀是关闭状态了,需要关闭MFC,
{
CloseMFC ( isOn , _mfcName );
return true ;
}
}
}
EV . PostInfoLog ( Module , $"Turn {Display} {ValveStateToString(isOn)}" );
reason = "" ;
SetPoint = isOn ;
_operation = isOn ;
_timer . Restart ( 2000 ); //2 seconds to monitor
return true ;
}
/// <summary>
/// 如果存在前置MFC,则等待MFC流量到0后再开关阀。
/// </summary>
private void MonitorMfc ()
{
lock ( _mfcLock )
{
if ( _mappedMfc != null )
{
if ( _mappedMfc . FeedBack < _mappedMfc . Scale * 0.015 ) // 等待MFC Ramp到0
{
SetPoint = _isValveOnAfterMfcRamp ;
_operation = _isValveOnAfterMfcRamp ;
_mappedMfc = null ;
_timMfcRampTimeout . Stop ();
_timer . Start ( 2000 );
}
else if ( _timMfcRampTimeout . IsTimeout ()) // 等待MFC Ramp 到0超时
{
_mappedMfc . StopRamp ();
_timMfcRampTimeout . Stop ();
EV . PostAlarmLog ( Module ,
$"Timeout to ramp {_mappedMfc.Name} to 0.0{_mappedMfc.Unit} when Turning {Name} {ValveStateToString(_isValveOnAfterMfcRamp)}" );
_mappedMfc = null ;
}
}
}
}
/// <summary>
/// 关闭前置MFC。
/// </summary>
/// <param name="isOn"></param>
/// <param name="_mfcName"></param>
private void CloseMFC ( bool isOn , string _mfcName )
{
lock ( _mfcLock )
{
// 获取前置MFC
_mappedMfc = DEVICE . GetDevice < IoMFC >( $"{Module}.{_mfcName}" );
if ( _mappedMfc == null )
{
// 如果未获取到前置MFC,则直接操作蝶阀
EV . PostWarningLog ( Module , $"Unable to find mapped MFC {_mfcName} of valve {Name}" );
EV . PostInfoLog ( Module , $"Turn {Display} {ValveStateToString(isOn)}" );
SetPoint = isOn ;
_operation = isOn ;
}
else
{
EV . PostInfoLog ( Module , $"Start to ramp {_mfcName} to 0.0{_mappedMfc.Unit}" );
_isValveOnAfterMfcRamp = isOn ;
_mappedMfc . Ramp ( 0 , 5 * 1000 );
_timMfcRampTimeout . Start ( 10 * 1000 );
}
_timer . Start ( 2000 );
}
}
private string ValveStateToString ( bool isOn )
{
return isOn ? "On" : "Off" ;
}
public void Reset ()
{
eventTrigger . RST = true ;
forceOpenTrigger . RST = true ;
lock ( _mfcLock )
{
if ( _mappedMfc != null )
{
_mappedMfc . Reset ();
_mappedMfc = null ;
_timMfcRampTimeout . Stop ();
}
}
}
}
public static class ValveToMFCMap
{
/// <summary>
/// Key= IoValve_id , Value=IoMFC_id
/// </summary>
public static Dictionary < string , string > ValveControlMFC = new Dictionary < string , string >()
{
//{ "TMVent","Mfc60" },
{ "V96" , $"Mfc38" },
{ "V94" , $"Mfc36" },
};
}
}