@@ -1,12 +1,13 @@
using System.Collections.Generic;
using System.Diagnostics;
using Aitex.Core.RT.Device;
using Aitex.Core.RT.Device;
using Aitex.Core.RT.Device.Devices;
using Aitex.Core.RT.Event;
using Aitex.Core.RT.Routine;
using Aitex.Core.RT.SCCore;
using MECF.Framework.Common.Equipment;
using MECF.Framework.RT.EquipmentLibrary.HardwareUnits.MFCs;
using SicModules.PMs.Routines.Base;
using System.Collections.Generic;
using System.Diagnostics;
namespace SicModules.PMs.Routines
{
@@ -30,7 +31,7 @@ namespace SicModules.PMs.Routines
SetGroupG,
SetGroupK,
SetM1to16,
SetM1toM17,
SetM17M18,
SetPC,
SetGroupJ,
@@ -50,7 +51,7 @@ namespace SicModules.PMs.Routines
SetGasIn2,
SetGroupJOpen,
SetM291519to26,
SetM18toM40,
OpenFinal2,
SetMfcFinal2,
@@ -122,7 +123,7 @@ namespace SicModules.PMs.Routines
SetTVEnable_2,
SetTVPressMode,
SetTv1,
SetM2toM40,
Set0M18toM40,
SetM18,
SetV31,
SetV32,
@@ -142,7 +143,6 @@ namespace SicModules.PMs.Routines
SetM18_1,
SetM18_2,
SetV92V93V95,
SetV94,
SetV96,
@@ -178,6 +178,30 @@ namespace SicModules.PMs.Routines
Notify2,
Notify3,
Notify4,
WaitPressUpTo950,
FirstWaitPressureUp,
FirstSetDefault_M18toM40,
FirstSet0_M18toM40,
FirstSetEPV2_1,
FirstSetEPV2_2,
FirstSetTv1,
LoopSetDefault_M18toM40,
LoopSetEPV2_1,
LoopWaitPressureUp,
LoopSetEPV2_2,
LoopSetTv1,
LoopSet0_M18toM40,
Loop2Set0_M18toM40,
LoopWaitTv1,
FinishSetM1toM17,
FinishSetM18toM40,
FinishVentPumpClose_1,
FinishCloseGroupV25,
FinishSetPressureUp2,
FinishSetTVto300
}
private ModuleName moduleName;
@@ -276,149 +300,115 @@ namespace SicModules.PMs.Routines
SetHeatEnable((int)RoutineStep.HeatEnable, false, _heatTimeOut);
SetRotationValve((int)RoutineStep.RotationEnable, _rotationCheckSpeed, false, _rotationCloseTimeout);
//关闭V72,打开V25
//3、 关闭 V72(GasBox.Vent.Pump) 打开 V25(GasBox.Vent.Bypass)。
SetIoValueByGroup((int)RoutineStep.VentPumpClose, IoGroupName.VentPump, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupV25, IoGroupName.V25, true, _IoValueOpenCloseTimeout);
//打开V103,关闭V105
SetIoValueByGroup((int)RoutineStep.SetV103, IoGroupName.V103, true, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetV105, IoGroupName.V105, false, _IoValueOpenCloseTimeout);
//打开V31,打开V32
//4、 打开 V31(H2.Supply)、 V32(Ar.Supply) 。
SetIoValueByGroup((int)RoutineStep.SetV31, IoGroupName.V31, true, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetV32, IoGroupName.V32, true, _IoValueOpenCloseTimeout);
//打开V35,打开V36
//5、 打开 V35(H2N2.Line1)、 V36(H2N2.Line2),关闭 B/C/E/F/H/KValves,打开 D/G Valves; 打开 J valve。
SetIoValueByGroup((int)RoutineStep.SetV35V36, IoGroupName.V35V36, true, _IoValueOpenCloseTimeout);
//关闭B/C/E/F/H/K 阀门
SetIoValueByGroup((int)RoutineStep.SetGroupB, IoGroupName.B, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupC, IoGroupName.C, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupE, IoGroupName.E, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupF, IoGroupName.F, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupH, IoGroupName.H, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupK, IoGroupName.K, false, _IoValueOpenCloseTimeout);
//打开D/G 阀门
SetIoValueByGroup((int)RoutineStep.SetGroupD, IoGroupName.D, true, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupG, IoGroupName.G, true, _IoValueOpenCloseTimeout);
//打开V65
SetIoValueByGroup((int)RoutineStep.SetV65, IoGroupName.V65, true, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupJ, IoGroupName.J, true, _IoValueOpenCloseTimeout);
//设置MFC和PC的模式
SetMfcModeToNormalByGroup((int)RoutineStep.SetMFCMode, MfcGroupName.All);
SetPcModeToNormal((int)RoutineStep.SetPCMode, _lstPcList);
//打开J阀门
SetIoValueByGroup((int)RoutineStep.SetGroupJ, IoGroupName.J, true, _IoValueOpenCloseTimeout);
//M1-M16设定为default值(M2、M9、M15除外)
SetMfcToDefaultByGroup((int)RoutineStep.SetM1to16, MfcGroupName.M1to16, 0);
SetMfcToDefaultByGroup((int)RoutineStep.SetM17M18, MfcGroupName.M17M18, 0);
//设置所有PC到默认值
//6、 M1-M17 设定为 default 值,所有 PC 设定为 default 值(PC1-PC9), M18-M40(除M30\M34\M39)) MFC 3s ramp 到 default 值。
SetMfcToDefaultByGroup((int)RoutineStep.SetM1toM17, MfcGroupName.M1toM17, 0);
SetPcToDefault((int)RoutineStep.SetPC, _lstPcList);
SetMfcToDefaultByGroup((int)RoutineStep.SetM18toM40, MfcGroupName.M18toM40No303439, 3);
//设置M2,M9,M15,M19-M26 3s ramp 到default 值
SetMfcToDefaultByGroup((int)RoutineStep.SetM291519to26, MfcGroupName.M2toM26, 3);
//打开EPV2
//7、打开 EPV2,等待 3s, 打开 TV enable, 压力模式,伺服压力默认设定为 0mbar;
SetIoValueByGroup((int)RoutineStep.SetEPV2, IoGroupName.EPV2, true, _IoValueOpenCloseTimeout);
TimeDelay((int)RoutineStep.TimeDelay1, 3);
//设置蝶阀Enable
SetThrottleEnableAndWait((int)RoutineStep.SetTVEnable_1, _IoThrottle, 5);
//设置蝶阀为压力模式
SetThrottleToPressModeAndWait((int)RoutineStep.SetTVPressMode, _IoThrottle, 5);
//伺服压力设定值到0mbar
SetThrottleToTargetAndNoWait((int)RoutineStep.SetTv1, _IoThrottle, _pressureMin);
//M2、M9、M15、M19-M40 MFC 5s ramp 到0
SetMfcByGroup((int)RoutineStep.SetM2toM40, MfcGroupName.M2toM42, 0, 5);
SetMfcByGroup((int)RoutineStep.SetM18, MfcGroupName.M18, 0, 5);
//8、当蝶阀设定值 ramp 到 0 后,将 M18-M40(除 M30\M34\M39)) MFC 3s ramp 到 0;
SetMfcByGroup((int)RoutineStep.Set0M18toM40, MfcGroupName.M18toM40No303439, 0, 3);
//等待腔体压力Pump到设定值
//9、等待腔体压力到 Pump Base Pressure(可配置),蝶阀改为位置模式,开度设定 100%
WaitChamberPressDownTo((int)RoutineStep.WaitTv1, _pressureMin, _pumpTimeout);
TimeDelay((int)RoutineStep.TimeDelay2, 3);
//蝶阀设置为位置模式,开度设置为最大
SetThrottleToPositionMode((int)RoutineStep.SetTVPositionMode, _IoThrottle, _throttleTimeout);
TimeDelay((int)RoutineStep.TimeDelay11, 3);
SetThrottleSetPosition((int)RoutineStep.SetTVPositionMax, _IoThrottle, 100, _throttleTimeout);
//Final2阀对应的MFC 3s Ramp到Default值
//10、 M27、 M28、 M29、 M31、 M33、 M40 依次设定 3S ramp 到 default 值 ;
SetMfcToDefaultByGroup((int)RoutineStep.SetMfcFinal2, MfcGroupName.Final2, 3);
//打开Final2阀
//11、打开 V87( SHPurge.Final)、 V88( OuterGas.Final)、 V89( InnerGas.Final)、 V90(MiddleGas.Final)、 V91(OpticPurge.Final)、 V97(CarryGas.Final);
SetIoValueByGroup((int)RoutineStep.OpenFinal2, IoGroupName.Final2, true, _IoValueOpenCloseTimeout);
//打开V68
//12、 打开 V68(ChamBody.N2.Purge)
SetIoValueByGroup((int)RoutineStep.SetV68, IoGroupName.GasIn1, true, _IoValueOpenCloseTimeout);
TimeDelay((int)RoutineStep.TimeDelay3, 1);
//打开V92,V93和V95,再打开V94,在打开V96
//13、 M32、 M35、 M36、 M37、 M38 依次设定 3S ramp 到 default 值 ;
SetMfcToDefaultByGroup((int)RoutineStep.SetM32M35M37, MfcGroupName.M32M35M37, 1);
SetMfcToDefaultByGroup((int)RoutineStep.SetM36, MfcGroupName.M36, 1);
SetMfcToDefaultByGroup((int)RoutineStep.SetM38, MfcGroupName.M38, 1);
TimeDelay((int)RoutineStep.TimeDelay4, 3);
//14、打开 V92(GasRingPurge.Final)、 V93(ChamberPurge.Final)、 V95(ConfinementRing.Final);
//等待 950,,打开 V94(RotationUpPurge.Final)、 等待 3S,打开 V96(HeaterWF.Final) ;
//蝶阀改为压力模式
SetIoValueByGroup((int)RoutineStep.SetV92V93V95, IoGroupName.V92V93V95, true, _IoValueOpenCloseTimeout);
WaitChamberPressUpTo((int)RoutineStep.WaitPressUpTo950, 950, 600);
SetIoValueByGroup((int)RoutineStep.SetV94, IoGroupName.V94, true, _IoValueOpenCloseTimeout);
TimeDelay((int)RoutineStep.TimeDelay4, 3);
SetIoValueByGroup((int)RoutineStep.SetV96, IoGroupName.V96, true, _IoValueOpenCloseTimeout);
SetThrottleToPressModeAndWait((int)RoutineStep.SetTVPressMode1, _IoThrottle, 5);
//M18 - M40(除 M30\M34\M39)) MFC 3s ramp 到 default 值。
//关闭 EPV2,等待压力达到设定值,压力达到后,打开 EPV2;
//M18 - M40(除 M30\M34\M39)) MFC 5s ramp 到 0。
//伺服压力到设定值 0(可配置)
SetMfcToDefaultByGroup((int)RoutineStep.FirstSetDefault_M18toM40, MfcGroupName.M18toM40No303439, 3);
SetIoValueByGroup((int)RoutineStep.FirstSetEPV2_1, IoGroupName.EPV2, false, _IoValueOpenCloseTimeout);
WaitThrottleToPressureAndSetMfcSpecial((int)RoutineStep.FirstWaitPressureUp, _IoThrottle, _pressureMax, _ventTimeout);
SetIoValueByGroup((int)RoutineStep.FirstSetEPV2_2, IoGroupName.EPV2, true, _IoValueOpenCloseTimeout);
SetMfcByGroup((int)RoutineStep.FirstSet0_M18toM40, MfcGroupName.M18toM40No303439, 0, 5);
SetThrottleToTargetAndNoWait((int)RoutineStep.FirstSetTv1, _IoThrottle, _pressureMin);
//循环开始
Loop((int)RoutineStep.StartLoop, _pressureLoopCount);
//M2、M9、M15、M19-M40 MFC 3s ramp 到 default 值
SetMfcToDefaultByGroup((int)RoutineStep.SetM2TOM40Default, MfcGroupName.M2toM42, 3);
SetMfcToDefaultByGroup((int)RoutineStep.SetM18Default, MfcGroupName.M18, 3);
//先关蝶阀,再关闭EPV2
SetThrottleToCloseMode((int)RoutineStep.SetTVCloseMode1, _IoThrottle, 8);
SetThrottleDisable((int)RoutineStep.CLoseTV1, _IoThrottle, 8);
TimeDelay((int)RoutineStep.TimeDelay5, 1);
SetIoValueByGroup((int)RoutineStep.SetEPV2_1, IoGroupName.EPV2, false, _IoValueOpenCloseTimeout);
SetPressureUpOrDown((int)RoutineStep.SetPressUpOrDown1, PressureUpOrDown.Uping);
WaitThrottleToPressureAndSetMfcSpecial((int)RoutineStep.WaitPressureUp, _IoThrottle, _pressureMax, _ventTimeout);
TimeDelay((int)RoutineStep.TimeDelay6, _pressureMaxDelay);
//打开EPV2
SetIoValueByGroup((int)RoutineStep.SetEPV2_2, IoGroupName.EPV2, true, _IoValueOpenCloseTimeout);
TimeDelay((int)RoutineStep.TimeDelay7, 1);
//设置蝶阀Enable
SetThrottleEnableAndWait((int)RoutineStep.SetTVEnable_2, _IoThrottle, 5);
//设置蝶阀为压力模式
SetThrottleToPressModeAndWait((int)RoutineStep.SetTVPressMode1, _IoThrottle, 5);
//M2、M9、M15、M19-M40 MFC 3s ramp 0
SetMfcByGroup((int)RoutineStep.SetM2toM40_1, MfcGroupName.M2toM42, 0, 3);
SetMfcByGroup((int)RoutineStep.SetM18_1, MfcGroupName.M18, 0, 3);
//伺服到0mbar
SetThrottlePressureAndWait((int)RoutineStep.SetPressureDown, _IoThrottle, _pressureMin, _pumpTimeout);
//M18 - M40(除 M30\M34\M39)) MFC 3s ramp 到 default 值。
//关闭 EPV2,等待压力达到设定值,压力达到后,打开 EPV2;
//M18 - M40(除 M30\M34\M39)) MFC 5s ramp 到 0。
//伺服压力到设定值 0(可配置)
//M18 - M40(除 M30\M34\M39)) MFC5s ramp 到 0。
//等待压力到达 0(可配置)
SetMfcToDefaultByGroup((int)RoutineStep.LoopSetDefault_M18toM40, MfcGroupName.M18toM40No303439, 3);
SetIoValueByGroup((int)RoutineStep.LoopSetEPV2_1, IoGroupName.EPV2, false, _IoValueOpenCloseTimeout);
WaitThrottleToPressureAndSetMfcSpecial((int)RoutineStep.LoopWaitPressureUp, _IoThrottle, _pressureMax, _ventTimeout);
SetIoValueByGroup((int)RoutineStep.LoopSetEPV2_2, IoGroupName.EPV2, true, _IoValueOpenCloseTimeout);
SetMfcByGroup((int)RoutineStep.LoopSet0_M18toM40, MfcGroupName.M18toM40No303439, 0, 5);
SetThrottleToTargetAndNoWait((int)RoutineStep.LoopSetTv1, _IoThrottle, _pressureMin);
SetMfcByGroup((int)RoutineStep.Loop2Set0_M18toM40, MfcGroupName.M18toM40No303439, 0, 5);
WaitChamberPressDownTo((int)RoutineStep.LoopWaitTv1, _pressureMin, _pumpTimeout);
EndLoop((int)RoutineStep.EndLoop);
//M27-M40 MFC 3s ramp 到 default 值
SetMfcToDefaultByGroup((int)RoutineStep.SetMfc2to40Default, MfcGroupName.M2toM42, 3);
SetMfcToDefaultByGroup((int)RoutineStep.SetM18_2, MfcGroupName.M18, 3);
//打开J阀门
SetIoValueByGroup((int)RoutineStep.SetGroupJ_1, IoGroupName.J, true, _IoValueOpenCloseTimeout);
//打开V72,关闭V25
SetIoValueByGroup((int)RoutineStep.VentPumpClose_1, IoGroupName.VentPump, true, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.CloseGroupV25, IoGroupName.V25, false, _IoValueOpenCloseTimeout);
//设置蝶阀为压力模式
SetThrottleToPressModeAndWait((int)RoutineStep.SetTVPressMode2, _IoThrottle, 5);
//压力伺服到300mbar
SetPressureUpOrDown((int)RoutineStep.SetPressUpOrDown2, PressureUpOrDown.Uping);
SetThrottleToTargetAndNoWait((int)RoutineStep.SetPressureUp2, _IoThrottle, _throttleFinalPressure);
WaitThrottleToPressureAndSetMfcSpecial((int)RoutineStep.SetTVto300, _IoThrottle, _throttleFinalPressure, _pmPressureMaxDiff, _throttleTimeout);
//设置 M1-M17 3s ramp 到 default; M18 - M40(除 M30\M34\M39)) MFC 3s ramp 到default 值。
//打开 V72(GasBox.Vent.Pump) 关闭 V25(GasBox.Vent.Bypass), 反应腔压力伺服到300mbar(可配置)
SetMfcToDefaultByGroup((int)RoutineStep.FinishSetM1toM17, MfcGroupName.M1toM17, 3);
SetMfcToDefaultByGroup((int)RoutineStep.FinishSetM18toM40, MfcGroupName.M18toM40No303439, 3);
SetIoValueByGroup((int)RoutineStep.FinishVentPumpClose_1, IoGroupName.VentPump, true, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.FinishCloseGroupV25, IoGroupName.V25, false, _IoValueOpenCloseTimeout);
SetThrottleToTargetAndNoWait((int)RoutineStep.FinishSetPressureUp2, _IoThrottle, _throttleFinalPressure);
WaitThrottleToPressureAndSetMfcSpecial((int)RoutineStep.FinishSetTVto300, _IoThrottle, _throttleFinalPressure, _pmPressureMaxDiff, _throttleTimeout);
}
catch (RoutineBreakException)
{