@ -116,7 +116,6 @@
|
||||
<IoValve id="TMVent" module="TM" display="V77" schematicId="TMVent" unit="" isNc="true" isDefaultOpen="false" diOpen="DI_TMVentFB" doOpen="DO_TMVent" />
|
||||
<IoValve id="UnLoadVent" module="TM" display="V78" schematicId="UnLoadVent" unit="" isNc="true" isDefaultOpen="false" diOpen="DI_UnloadVentFB" doOpen="DO_UnloadVent" />
|
||||
<IoValve id="TMLoadBanlance" module="TM" display="V85" schematicId="TMLoadBanlance" unit="" isNc="true" isDefaultOpen="false" diOpen="DI_TMLoadBanlanceFB" doOpen="DO_TMLoadBanlance" />
|
||||
<IoValve id="TMUnLoadBanlance" module="TM" display="V124" schematicId="TMToUnloadBanlance" unit="" isNc="true" isDefaultOpen="false" diOpen="" doOpen="DO_TMToUnloadBanlance" />
|
||||
</IoValves>
|
||||
<IoSlitValves classType="Aitex.Core.RT.Device.Unit.IoSlitValve" assembly="MECF.Framework.RT.EquipmentLibrary">
|
||||
<IoSlitValve id="LoadLockDoor" module="TM" display="LLDoor" Type="" unit="" schematicId="LLDoor" scTimeout="System.SlitValveMotionTimeout" diOpen="DI_LoadDoorOpened" diClose="DI_LoadDoorClosed" doOpen="DO_LoadDoorOpen" doClose="DO_LoadDoorClose" />
|
||||
|
||||
@ -244,7 +244,6 @@ namespace SicModules.PMs.Routines
|
||||
SetThrottleToPositionMode((int)RoutineStep.SetTVPositionMode, _IoThrottle, _throttleTimeout);
|
||||
SetThrottleSetPosition((int)RoutineStep.SetTVPositionMax, _IoThrottle, 100, _throttleTimeout);
|
||||
|
||||
_pmIoInterLock.SetPMPumpRoutineRunning(false, out _);
|
||||
}
|
||||
catch (RoutineBreakException)
|
||||
{
|
||||
@ -255,6 +254,7 @@ namespace SicModules.PMs.Routines
|
||||
return Result.FAIL;
|
||||
}
|
||||
|
||||
_pmIoInterLock.SetPMPumpRoutineRunning(false, out _);
|
||||
Notify($"Finished ! Elapsed time: {(int)(_swTimer.ElapsedMilliseconds / 1000)} s");
|
||||
_swTimer.Stop();
|
||||
|
||||
|
||||
@ -34,7 +34,7 @@ namespace SicModules.PMs.Routines
|
||||
|
||||
SetM1to16,
|
||||
SetM17M18,
|
||||
SetM2toM40,
|
||||
SetM18toM40,
|
||||
SetPC,
|
||||
SetM291519to38,
|
||||
SetGroupJ,
|
||||
@ -79,9 +79,9 @@ namespace SicModules.PMs.Routines
|
||||
SetV31,
|
||||
SetV32,
|
||||
SetV35V36,
|
||||
SetGroupV25,
|
||||
SetV103,
|
||||
SetV105,
|
||||
SetGroupV25,
|
||||
|
||||
SetV92V93V95,
|
||||
SetV94,
|
||||
@ -164,7 +164,7 @@ namespace SicModules.PMs.Routines
|
||||
{
|
||||
CheckRoutineTimeOut();
|
||||
|
||||
//关闭V76,打开V75
|
||||
//DOR Pump 抽真空。关闭V76,打开V75
|
||||
SetIoValueByGroup((int)RoutineStep.SetV76, IoGroupName.V76, false, _IoValueOpenCloseTimeout);
|
||||
SetIoValueByGroup((int)RoutineStep.SetV75, IoGroupName.V75, true, _IoValueOpenCloseTimeout);
|
||||
|
||||
@ -175,91 +175,62 @@ namespace SicModules.PMs.Routines
|
||||
//关闭V72,打开V25
|
||||
SetIoValueByGroup((int)RoutineStep.VentPumpClose, IoGroupName.VentPump, false, _IoValueOpenCloseTimeout);
|
||||
SetIoValueByGroup((int)RoutineStep.SetGroupV25, IoGroupName.V25, true, _IoValueOpenCloseTimeout);
|
||||
//打开V103,关闭V105
|
||||
SetIoValueByGroup((int)RoutineStep.SetV103, IoGroupName.V103, true, _IoValueOpenCloseTimeout);
|
||||
SetIoValueByGroup((int)RoutineStep.SetV105, IoGroupName.V105, false, _IoValueOpenCloseTimeout);
|
||||
|
||||
//打开V31,打开V32
|
||||
SetIoValueByGroup((int)RoutineStep.SetV31, IoGroupName.V31, true, _IoValueOpenCloseTimeout);
|
||||
SetIoValueByGroup((int)RoutineStep.SetV32, IoGroupName.V32, true, _IoValueOpenCloseTimeout);
|
||||
|
||||
//打开V35,打开V36
|
||||
//5、 打开 V35(H2N2.Line1)、 V36(H2N2.Line2) , 关闭 B/ C / E / F / H / K Valves,打开 D/ G Valves 。
|
||||
SetIoValueByGroup((int)RoutineStep.SetV35V36, IoGroupName.V35V36, true, _IoValueOpenCloseTimeout);
|
||||
|
||||
//关闭B/C/E/F/H/K 阀门
|
||||
SetIoValueByGroup((int)RoutineStep.SetGroupB, IoGroupName.B, false, _IoValueOpenCloseTimeout);
|
||||
SetIoValueByGroup((int)RoutineStep.SetGroupC, IoGroupName.C, false, _IoValueOpenCloseTimeout);
|
||||
SetIoValueByGroup((int)RoutineStep.SetGroupE, IoGroupName.E, false, _IoValueOpenCloseTimeout);
|
||||
SetIoValueByGroup((int)RoutineStep.SetGroupF, IoGroupName.F, false, _IoValueOpenCloseTimeout);
|
||||
SetIoValueByGroup((int)RoutineStep.SetGroupH, IoGroupName.H, false, _IoValueOpenCloseTimeout);
|
||||
SetIoValueByGroup((int)RoutineStep.SetGroupK, IoGroupName.K, false, _IoValueOpenCloseTimeout);
|
||||
|
||||
//打开D/G 阀门
|
||||
SetIoValueByGroup((int)RoutineStep.SetGroupD, IoGroupName.D, true, _IoValueOpenCloseTimeout);
|
||||
SetIoValueByGroup((int)RoutineStep.SetGroupG, IoGroupName.G, true, _IoValueOpenCloseTimeout);
|
||||
|
||||
//设置MFC和PC的模式
|
||||
SetMfcModeToNormalByGroup((int)RoutineStep.SetMFCMode, MfcGroupName.All);
|
||||
SetPcModeToNormal((int)RoutineStep.SetPCMode, _lstPcList);
|
||||
|
||||
//M1-M16设定为default值(M2、M9、M15除外)
|
||||
SetMfcToDefaultByGroup((int)RoutineStep.SetM1to16, MfcGroupName.M1to16, 0);
|
||||
SetMfcToDefaultByGroup((int)RoutineStep.SetM17M18, MfcGroupName.M17M18, 0);
|
||||
|
||||
//设置所有PC到默认值
|
||||
//6、 M1-M17 设定为 default 值, 所有 PC 设定为 default 值(PC1-PC9) ,M18 - M40(除 M30\M34\M39) MFC 5s ramp 到 0。
|
||||
SetMfcModeToNormalByGroup((int)RoutineStep.SetMFCMode, MfcGroupName.M1toM17);
|
||||
SetPcToDefault((int)RoutineStep.SetPC, _lstPcList);
|
||||
SetMfcToDefaultByGroup((int)RoutineStep.SetM18toM40, MfcGroupName.M18toM40No303439, 5);
|
||||
|
||||
//M2、M9、M15、M19-M40 MFC 3s ramp 到默认值
|
||||
SetMfcToDefaultByGroup((int)RoutineStep.SetM2toM40, MfcGroupName.M2toM42, 3);
|
||||
|
||||
//关闭蝶阀
|
||||
//7、 关闭蝶阀, 再关闭 EPV2
|
||||
SetThrottleToCloseMode((int)RoutineStep.SetTVCloseMode, _IoThrottle, 8);
|
||||
SetThrottleDisable((int)RoutineStep.SetTvPositionToZero, _IoThrottle, 8);
|
||||
TimeDelay((int)RoutineStep.TimeDelay1, 1);
|
||||
|
||||
//关闭EPV2
|
||||
SetIoValueByGroup((int)RoutineStep.SetEPV2, IoGroupName.EPV2, false, _IoValueOpenCloseTimeout);
|
||||
|
||||
//打开A 组阀
|
||||
//8、 打开 A Valves(V33S(SH.H2/N2 Switch); V67、 V68(N2.Supply) ).
|
||||
SetIoValueByGroup((int)RoutineStep.SetGroupA, IoGroupName.A, true, _IoValueOpenCloseTimeout);
|
||||
|
||||
//打开Final2阀
|
||||
//9 、 打 开 V87 ( SHPurge.Final )、 V88 ( OuterGas.Final )、 V89 ( InnerGas.Final )、 V90(MiddleGas.Final) 、 V91(OpticPurge.Final)、 V97(CarryGas.Final) ;
|
||||
//M27、 M28、 M29、 M31、 M33、 M40 依次设定 3S ramp 到 default 值 ;
|
||||
SetIoValueByGroup((int)RoutineStep.OpenFinal2, IoGroupName.Final2, true, _IoValueOpenCloseTimeout);
|
||||
|
||||
//Final2阀对应的MFC 3s Ramp到Default值
|
||||
SetMfcToDefaultByGroup((int)RoutineStep.SetMfcFinal2, MfcGroupName.Final2, 3);
|
||||
|
||||
//10、 打开 V92(GasRingPurge.Final)、 V93(ChamberPurge.Final)、 V95(ConfinementRing.Final);等待 3S
|
||||
SetIoValueByGroup((int)RoutineStep.SetV92V93V95, IoGroupName.V92V93V95, true, _IoValueOpenCloseTimeout);
|
||||
TimeDelay((int)RoutineStep.TimeDelay2, 3);
|
||||
|
||||
//11、 M32、 M35、 M37 依次设定 3S ramp 到 default 值 ; 等待 3S,
|
||||
SetMfcToDefaultByGroup((int)RoutineStep.SetM32M35M37, MfcGroupName.M32M35M37, 3);
|
||||
|
||||
//打开V68
|
||||
SetIoValueByGroup((int)RoutineStep.SetV68, IoGroupName.GasIn1, true, _IoValueOpenCloseTimeout);
|
||||
|
||||
//打开J Valves
|
||||
//12、 打开 J Valves ;设置 M18-M26 3s ramp 到 default 值。
|
||||
//等到腔体压力达到 900 mbar打开 V94(RotationUpPurge.Final)、 M36 设定 5S ramp 到 default 值;
|
||||
//等待 3S,打开 V96(HeaterWF.Final); M38 设定 5S ramp 到 default 值;
|
||||
SetIoValueByGroup((int)RoutineStep.SetGroupJOpen, IoGroupName.J, true, _IoValueOpenCloseTimeout);
|
||||
|
||||
//设置M2,M9,M15,M19-M26 3s ramp 到default 值
|
||||
SetMfcToDefaultByGroup((int)RoutineStep.SetM291519to26, MfcGroupName.M2toM26, 3);
|
||||
|
||||
//开V94,V96需等到腔体压力大于950
|
||||
WaitPMPressureAndSetMfcSpecial((int)RoutineStep.WaitPmPressureUp1, 950, _waitPMPressureUpTimeout);
|
||||
|
||||
WaitPMPressureAndSetMfcSpecial((int)RoutineStep.WaitPmPressureUp1, 900, _waitPMPressureUpTimeout);
|
||||
SetIoValueByGroup((int)RoutineStep.SetV94, IoGroupName.V94, true, _IoValueOpenCloseTimeout);
|
||||
SetMfcToDefaultByGroup((int)RoutineStep.SetM36, MfcGroupName.M36, 5);
|
||||
TimeDelay((int)RoutineStep.TimeDelay3, 3);
|
||||
|
||||
SetIoValueByGroup((int)RoutineStep.SetV96, IoGroupName.V96, true, _IoValueOpenCloseTimeout);
|
||||
SetMfcToDefaultByGroup((int)RoutineStep.SetM38, MfcGroupName.M38, 5);
|
||||
TimeDelay((int)RoutineStep.TimeDelay4, 3);
|
||||
|
||||
//等待反应腔压力大于1000
|
||||
//13、 压力达到 1020,结束
|
||||
NotifyInfo((int)RoutineStep.Notify1, $"Wait pm pressure to {_ventBasePressure} mbar!");
|
||||
WaitPMPressureAndSetMfcSpecial((int)RoutineStep.WaitPmPressureUp, _ventBasePressure, _waitPMPressureUpTimeout);
|
||||
|
||||
//设置M28,M29,M31,M40 3s ramp 到default 值
|
||||
SetMfcToDefaultByGroup((int)RoutineStep.SetMfc28to40Default, MfcGroupName.M28293140, 3);
|
||||
WaitPMPressureAndSetMfcSpecial((int)RoutineStep.WaitPmPressureUp, _ventBasePressure, _waitPMPressureUpTimeout); //等待反应腔压力大于1000
|
||||
}
|
||||
catch (RoutineBreakException)
|
||||
{
|
||||
|
||||
@ -68,7 +68,6 @@ namespace SicModules.PMs.Routines
|
||||
SetTvModeToPress,
|
||||
SetTVto1050,
|
||||
OpenGasIn1,
|
||||
SetV65,
|
||||
CloseGasIn1,
|
||||
CloseFinanl1,
|
||||
CloseFinanl2,
|
||||
@ -81,6 +80,7 @@ namespace SicModules.PMs.Routines
|
||||
SetV32,
|
||||
SetV35V36,
|
||||
SetV87V97,
|
||||
SetV65,
|
||||
SetV103,
|
||||
SetV105,
|
||||
SetTVPositionMode,
|
||||
|
||||
@ -233,8 +233,6 @@ namespace SicModules.PMs.Routines
|
||||
NotifyInfo((int)RoutineStep.Notify1, $"Wait pm pressure to {_ventBasePressure} mbar!");
|
||||
WaitPMPressureAndSetMfcSpecial((int)RoutineStep.WaitPmPressureUp, _ventBasePressure, _waitPMPressureUpTimeout); //等待反应腔压力大于1000
|
||||
|
||||
_pmIoInterLock.SetPMVentRoutineRunning(false, out _);
|
||||
|
||||
}
|
||||
catch (RoutineBreakException)
|
||||
{
|
||||
@ -245,6 +243,7 @@ namespace SicModules.PMs.Routines
|
||||
return Result.FAIL;
|
||||
}
|
||||
|
||||
_pmIoInterLock.SetPMVentRoutineRunning(false, out _);
|
||||
Notify($"Finished ! Elapsed time: {(int)(_swTimer.ElapsedMilliseconds / 1000)} s");
|
||||
_swTimer.Stop();
|
||||
|
||||
|
||||
@ -1860,5 +1860,31 @@ namespace SicModules.TMs.Routines
|
||||
throw (new RoutineBreakException());
|
||||
}
|
||||
}
|
||||
|
||||
public void SetTMLLBalanceValve(int id, TM tm,bool value)
|
||||
{
|
||||
Tuple<bool, Result> ret = Execute(id, () =>
|
||||
{
|
||||
Notify($"{(value ? "Open":"Close")} {tm.Name} balance valve");
|
||||
|
||||
if (!tm.SetSlowVentValve(value, out string reason))
|
||||
{
|
||||
Stop(reason);
|
||||
return false;
|
||||
}
|
||||
|
||||
return true;
|
||||
});
|
||||
|
||||
if (ret.Item1)
|
||||
{
|
||||
if (ret.Item2 == Result.FAIL)
|
||||
{
|
||||
throw (new RoutineFaildException());
|
||||
}
|
||||
else
|
||||
throw (new RoutineBreakException());
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
@ -10,6 +10,7 @@ namespace SicModules.TMs.Routines
|
||||
{
|
||||
CloseV77,
|
||||
CloseV80,
|
||||
CloseV85,
|
||||
TMRobotHome
|
||||
}
|
||||
|
||||
@ -42,8 +43,11 @@ namespace SicModules.TMs.Routines
|
||||
{
|
||||
try
|
||||
{
|
||||
//关闭 V77, V78; 关闭 V85;关闭 V70-1, V70-2; Home Robot, Check Load
|
||||
CloseTMVent((int)RoutineStep.CloseV77);
|
||||
//CloseBufferVent((int)RoutineStep.CloseV80);
|
||||
//没有V78
|
||||
SetTMLLBalanceValve((int)RoutineStep.CloseV85, TMDevice,false);
|
||||
//没有V70
|
||||
ExecuteRoutine((int)RoutineStep.TMRobotHome, _tmRobotHomeRoutine);
|
||||
}
|
||||
catch (RoutineBreakException)
|
||||
|
||||