load伺服配置不隐藏

删除tm控制v124代码
This commit is contained in:
SIC1016\caipeilun
2026-08-18 19:18:07 +08:00
parent 8338d5d9f7
commit c6bcd06b61
8 changed files with 137 additions and 174 deletions
@@ -12,7 +12,8 @@ namespace SicModules.LLs.Routines
{
CloseV79,
CloseV83,
CloseV84
CloseV84,
CloseV85
}
private int _homeTimeout;
@@ -41,6 +42,7 @@ namespace SicModules.LLs.Routines
CloseLoadVent((int)RoutineStep.CloseV79);
CloseFastPump((int)RoutineStep.CloseV83);
CloseSlowPump((int)RoutineStep.CloseV84);
CloseBalanceValve((int)RoutineStep.CloseV85);
LoadLockDevice.AutoCreatWafer();
}
@@ -59,84 +61,6 @@ namespace SicModules.LLs.Routines
return Result.DONE;
}
public void CloseLoadVent(int id)
{
Tuple<bool, Result> ret = Execute(id, () =>
{
Notify($"Close Load vent valve");
if (!LoadLockDevice.SetFastVentValve(false, out string reason))
{
Stop(reason);
return false;
}
return true;
});
if (ret.Item1)
{
if (ret.Item2 == Result.FAIL)
{
throw (new RoutineFaildException());
}
else
throw (new RoutineBreakException());
}
}
public void CloseFastPump(int id)
{
Tuple<bool, Result> ret = Execute(id, () =>
{
Notify($"Close Load fast pump valve");
if (!LoadLockDevice.SetFastPumpValve(false, out string reason))
{
Stop(reason);
return false;
}
return true;
});
if (ret.Item1)
{
if (ret.Item2 == Result.FAIL)
{
throw (new RoutineFaildException());
}
else
throw (new RoutineBreakException());
}
}
public void CloseSlowPump(int id)
{
Tuple<bool, Result> ret = Execute(id, () =>
{
Notify($"Close slow pump valve");
if (!LoadLockDevice.SetSlowPumpValve(false, out string reason))
{
Stop(reason);
return false;
}
return true;
});
if (ret.Item1)
{
if (ret.Item2 == Result.FAIL)
{
throw (new RoutineFaildException());
}
else
throw (new RoutineBreakException());
}
}
public override void Abort()
{
base.Abort();
@@ -87,6 +87,7 @@ namespace SicModules.LLs.Routines
LoadLockDevice.SetSlowPumpValve(false, out _);
LoadLockDevice.SetFastPumpValve(false, out _);
LoadLockDevice.SetSlowVentValve(false, out _);
TMDevice.SetTmToLLVent(false, out _);
}
protected void LiftMove(int id, bool up, int timeout)
@@ -855,5 +856,109 @@ namespace SicModules.LLs.Routines
return CCDTriggerResult;
}
public void CloseLoadVent(int id)
{
Tuple<bool, Result> ret = Execute(id, () =>
{
Notify($"Close Load vent valve");
if (!LoadLockDevice.SetFastVentValve(false, out string reason))
{
Stop(reason);
return false;
}
return true;
});
if (ret.Item1)
{
if (ret.Item2 == Result.FAIL)
{
throw (new RoutineFaildException());
}
else
throw (new RoutineBreakException());
}
}
public void CloseFastPump(int id)
{
Tuple<bool, Result> ret = Execute(id, () =>
{
Notify($"Close Load fast pump valve");
if (!LoadLockDevice.SetFastPumpValve(false, out string reason))
{
Stop(reason);
return false;
}
return true;
});
if (ret.Item1)
{
if (ret.Item2 == Result.FAIL)
{
throw (new RoutineFaildException());
}
else
throw (new RoutineBreakException());
}
}
public void CloseSlowPump(int id)
{
Tuple<bool, Result> ret = Execute(id, () =>
{
Notify($"Close slow pump valve");
if (!LoadLockDevice.SetSlowPumpValve(false, out string reason))
{
Stop(reason);
return false;
}
return true;
});
if (ret.Item1)
{
if (ret.Item2 == Result.FAIL)
{
throw (new RoutineFaildException());
}
else
throw (new RoutineBreakException());
}
}
public void CloseBalanceValve(int id)
{
Tuple<bool, Result> ret = Execute(id, () =>
{
Notify($"Close Balance valve V85");
if (!TMDevice.SetTmToLLVent(false, out string reason))
{
Stop(reason);
return false;
}
return true;
});
if (ret.Item1)
{
if (ret.Item2 == Result.FAIL)
{
throw (new RoutineFaildException());
}
else
throw (new RoutineBreakException());
}
}
}
}
@@ -22,6 +22,8 @@ namespace SicModules.LLs.Routines
CloseFastValve,
Delay,
TimeDelay1,
CloseV79,
CloseV85
}
private double _pumpBasePressure=0;
@@ -138,8 +140,12 @@ namespace SicModules.LLs.Routines
{
try
{
//关闭 V79, V85;打开 V84,等待压力低于 200mbar(可配置),打开 V83,压力达到 0mbar(可配置),等待 5s(可配置),关闭 V83、 V84。 Routine 结束。
CheckRoutineTimeOut();
CloseLoadVent((int)RoutineStep.CloseV79);
CloseBalanceValve((int)RoutineStep.CloseV85);
TimeDelay((int)RoutineStep.RequestPumpDelay, 1);
SlowPump((int)RoutineStep.SlowPump, _pumpSwitchPressure, _slowPumpTimeout);
@@ -18,6 +18,7 @@ namespace SicModules.LLs.Routines
CloseSlowVentValve,
CloseFastVentValve,
CloseValveDelay,
CloseFastPumpValve, CloseSlowPumpValve, CloseV85
}
private double _ventBasePressure;
@@ -110,8 +111,13 @@ namespace SicModules.LLs.Routines
{
try
{
//关闭 V83, V84, V85;打开 V79,等到压力等于 ATM(1020mbar 可配置),等待 5s(可配置),关闭 V79。 Routine 结束。
CheckRoutineTimeOut();
CloseFastPumpValve((int)RoutineStep.CloseFastPumpValve);
CloseSlowPumpValve((int)RoutineStep.CloseSlowPumpValve);
CloseBalanceValve((int)RoutineStep.CloseV85);
SlowVent((int)RoutineStep.SlowVent, _ventBasePressure, _slowVentTimeout);
TimeDelay((int)RoutineStep.VentDelay, _ventDelayTime);