using Aitex.Core.RT.Event;
using Aitex.Core.RT.Log;
using Aitex.Core.RT.SCCore;
using Aitex.Core.Util;
using MECF.Framework.Common.Communications;
using System;
using System.Collections.Generic;
using System.Linq;
using System.Threading;
using System.Xml;
namespace MECF.Framework.RT.EquipmentLibrary.HardwareUnits.Temps
{
public sealed class AETemp : TempSensorBase
{
private AETempConnection _connection;
private readonly R_TRIG _trigCommunicationError = new ();
private readonly R_TRIG _trigFewChannels = new ();
private readonly R_TRIG _trigMonitorExcepted = new ();
private readonly LinkedList<HandlerBase> _lstHandler = new ();
private readonly object _locker = new ();
private double[] _tempBuff;
/// <summary>
/// 设备通道启用
/// </summary>
private bool[] _channelInstalled;
public override bool IsConnected => _connection is { IsConnected: true };
public AETemp(string module, XmlElement node, string ioModule = "") : base(module, node, ioModule)
{
RTrigs.Add(_trigCommunicationError);
RTrigs.Add(_trigFewChannels);
RTrigs.Add(_trigMonitorExcepted);
}
private void QueryTemp()
{
lock (_locker)
{
_lstHandler.AddLast(new AETempReadCommandHandler(this, "OUT", "1"));
}
}
protected override bool HandleInitialize()
{
InitController();
_channelInstalled=new bool[MaxChannels];
for (int i = 0; i < _channelInstalled.Length; i++)
_channelInstalled[i] = SC.GetValue<bool>($"{ScBasePath}.{Name}.Channel{i+1}");
_tempBuff = new double[MaxChannels];
return true;
}
private void InitController()
{
Address = SC.GetStringValue($"{ScBasePath}.{Name}.Address");
_connection = new AETempConnection(Address);
_connection.EnableLog(IsEnableLog);
SC.RegisterValueChangedCallback($"TempSensors.EnableLogMessage", (obj) =>
{
_connection.EnableLog((bool)obj);
});
}
protected override double[] HandleReadTemp()
{
OnTimeQueryTemp();
return IsConnected ? _tempBuff : null;
}
protected void OnTimeQueryTemp()
{
try
{
_connection.MonitorTimeout();
if (!_connection.IsConnected || _connection.IsCommunicationError)
{
lock (_locker)
{
_lstHandler.Clear();
}
//只要断开,就进行连接
if (!_connection.Connect())
{
_trigCommunicationError.CLK = !_connection.IsConnected;
if (_trigCommunicationError.Q)
{
TempBasFunction.PM1PM2PostLog($"Can not connect with {_connection.Address}, {Module}.{Name}",EV.PostAlarmLog);
TempBasFunction.SetPm1Pm2IoForInterlock(true);
}
_connection.ForceClear();
Thread.Sleep(1000);//重连延时
}
else
{
//连接成功后不会再进入所以也只是写入一次LOG
LOG.Write($"{Module} {Name} Connected");
EV.PostInfoLog(Module, $"{Name} Connected");
TempBasFunction.PM1PM2PostLog($"{Name} Connected", EV.PostInfoLog);
TempBasFunction.SetPm1Pm2IoForInterlock(false);
}
_trigCommunicationError.CLK = !_connection.IsConnected;
_connection.ForceClear();
}
else
{
lock (_locker)
{
if (_lstHandler.Count == 0)
QueryTemp();
if (_lstHandler.Count > 0 && !_connection.IsBusy)
{
var handler = _lstHandler.First.Value;
_lstHandler.RemoveFirst();
if (handler != null)
{
_connection.Execute(handler);
}
}
}
}
}
catch (Exception ex)
{
_trigMonitorExcepted.CLK = true;
if(_trigMonitorExcepted.Q)
LOG.Write(ex);
}
}
public void ParseCommandInfo(string command, string message)
{
try
{
switch (command)
{
case "OUT":
{
if (message != null)
{
if (message.Contains(" "))
{
var strs = message.Split(' ');
if (strs.Length > 0 )
{
//判断AE温度通道启用和上位机设定通道启用是否相同
if (strs.Length != _channelInstalled.Count(c => c == true))
{
_trigFewChannels.CLK = true;
if (_trigFewChannels.Q)
{
TempBasFunction.PM1PM2PostLog("AE Error: Too few channels.", EV.PostAlarmLog);
}
return;
}
//温度数组,根据通道是否屏蔽来赋值,
_trigFewChannels.RST = true;
for (int i = 0; i < strs.Length; i++)
{
if (_channelInstalled[i] == true)
{
_tempBuff[i] = float.Parse(strs[i]);
}
}
//温度连续多次不变化侦测
//TempInvariantCount = TempBasFunction.TempInvariantCount(TempDatasArray, out string tempInvariantData);
//_trigTempNoChange.CLK = TempInvariantCount >= TempInvariantCountMax ? true : false;
//if (_trigTempNoChange.Q)
//{
// TempBasFunction.PM1PM2PostLog($"{Name} {TempInvariantCount} temp no changeCount {tempInvariantData}", EV.PostWarningLog);
//}
}
}
}
}
break;
}
}
catch (Exception ex)
{
// ignored
}
}
public override void Reset()
{
_connection?.SetCommunicationError(false, "");
base.Reset();
}
public override void Terminate()
{
_connection.Disconnect();
}
}
}