using Aitex.Core.RT.Device;
using Aitex.Core.RT.Device.Devices;
using Aitex.Core.RT.Event;
using Aitex.Core.RT.Routine;
using Aitex.Core.RT.SCCore;
using MECF.Framework.Common.Equipment;
using MECF.Framework.RT.EquipmentLibrary.HardwareUnits.MFCs;
using SicModules.PMs.Routines.Base;
using System.Collections.Generic;
using System.Diagnostics;
namespace SicModules.PMs.Routines
{
public class PMCleanRoutine : PMBaseRoutine
{
private enum RoutineStep
{
RotationEnable,
HeatEnable,
VentPumpClose,
VentPumpClose_1,
VentPumpOpen,
ArSupply,
SetGroupB,
SetGroupC,
SetGroupE,
SetGroupF,
SetGroupH,
SetGroupD,
SetGroupG,
SetGroupK,
SetM1toM17,
SetM17M18,
SetPC,
SetGroupJ,
SetGroupJ_1,
SetM291519to38,
SetGasOut,
SetTv,
SetGasIn1, //V68
OpenFinal1, //V91-96
SetMfcFinal1, //M32-38
SetMfc19to26,
SetTVCloseMode,
SetTvPositionToZero,
SetGasIn2,
SetGroupJOpen,
SetM18toM40,
OpenFinal2,
SetMfcFinal2,
SetEPV1,
SetEPV2,
SetEPV2_1,
SetEPV2_2,
SetEPV2_3,
SetTvMode,
RoutinePre,
V27Open,
V27Close,
PressureTo1050,
SetPressureUp,
SetPressureUp1,
SetPressureUp2,
SetPressureDown,
PressureToMax,
PressureToMin,
SetPressUpOrDown1,
SetPressUpOrDown2,
WaitPressureDown,
WaitPressureUp,
SetMFCMode,
SetPCMode,
WaitPmTo1050,
SetTvOpen,
SetTvModeToPress,
SetEPV22,
SetV76,
SetV75,
SetTVto300,
CheckPM1000,
SetMfc28to40Special,
WaitPressUpTo1000,
SetMfc28to40Default,
SetPC567Close,
SetPC567Mode,
SetPC567Default,
OpenEPV2,
WaitV27Open,
SetTvTo1150,
WaitPressUpTo20,
SetMfc28to31To0,
WaitPressUpTo0,
SetMfc28to31ToDefault,
WaitPressDownTo20,
CheckPMPt21000,
SetPressureDown1,
SetMfc28to31Default1,
CheckFinal1Open,
SetGroupV25,
CloseGroupV25,
SetM39,
CheckEPV1Open1,
CheckEPV2Open1,
CheckTVOpen1,
CheckEPV1Open2,
SetTVEnable_1,
SetTVEnable_2,
SetTVPressMode,
SetTv1,
Set0M18toM40,
SetM18,
SetV31,
SetV32,
SetV35V36,
SetV65,
WaitTv1,
SetTVPositionMode,
SetTVPositionMode_1,
SetTVPositionMax,
SetTVPositionMax_1,
SetTVPressMode1,
SetTVPressMode2,
SetM2TOM40Default,
SetM2toM40_1,
SetMfc2to40Default,
SetM18Default,
SetM18_1,
SetM18_2,
SetV92V93V95,
SetV94,
SetV96,
SetV103,
SetV105,
SetV68,
SetM32M35M37,
SetM36,
SetM38,
WaitPmPressureUp1,
SetTVCloseMode1,
CLoseTV1,
StartLoop,
EndLoop,
TimeDelay1,
TimeDelay2,
TimeDelay3,
TimeDelay4,
TimeDelay5,
TimeDelay6,
TimeDelay7,
TimeDelay8,
TimeDelay9,
TimeDelay10,
TimeDelay11,
TimeDelay18,
TimeDelay20,
TimeDelay21,
TimeDelay22,
Notify1,
Notify2,
Notify3,
Notify4,
WaitPressUpTo950,
FirstWaitPressureUp,
FirstSetDefault_M18toM40,
FirstSet0_M18toM40,
FirstSetEPV2_1,
FirstSetEPV2_2,
FirstSetTv1,
LoopSetDefault_M18toM40,
LoopSetEPV2_1,
LoopWaitPressureUp,
LoopSetEPV2_2,
LoopSetTv1,
LoopSet0_M18toM40,
Loop2Set0_M18toM40,
LoopWaitTv1,
FinishSetM1toM17,
FinishSetM18toM40,
FinishVentPumpClose_1,
FinishCloseGroupV25,
FinishSetPressureUp2,
FinishSetTVto300
}
private ModuleName moduleName;
private PMModule _pmModule;
private IoThrottleValve2 _IoThrottle;
//private IoInterLock _pmIoInterLock;
private int _rotationCheckSpeed = 0; //设置旋转速度为0后检查是否转速低于此数值
private int _rotationCloseTimeout = 20; //旋转停止超时
private int _heatTimeOut = 5; //Heat关闭等待Di反馈超时时间
private int _pressureMaxDelay = 10; //到低压保持时间采用固定值10s
private int _pressureMinDelay = 10; //到高压保持时间采用固定值10s
private double _pressureMax; //Loop压力上限可设置600-800
private double _pressureMin; //Loop压力下限可设置 0-400
private int _pressureMinTimeout;
private int _pressureMaxTimeout;
private int _pressureLoopCount; //Loop次数
private int _IoValueOpenCloseTimeout = 10; //开关阀门超时时间
private double _pmPressureMaxDiff; //蝶阀与目标压力的差值范围(认为调整到位了)
private int _throttleTimeout; //蝶阀调整到指定压力的超时时间
private int _ventTimeout;
private int _pumpTimeout;
private double _throttleFinalPressure = 300;//蝶阀最终调整对的压力
private int _pmCleanTime = 20;
private Stopwatch _swTimer = new Stopwatch();
public PMCleanRoutine(ModuleName module, PMModule pm) : base(module, pm)
{
moduleName = module;
_pmModule = pm;
Name = "Clean";
_IoThrottle = DEVICE.GetDevice<IoThrottleValve2>($"{Module}.TV");
//_pmIoInterLock = DEVICE.GetDevice<IoInterLock>($"{Module}.PMInterLock");
}
public override Result Start(params object[] objs)
{
Reset();
_pmPressureMaxDiff = SC.GetValue<double>($"PM.{Module}.ThrottlePressureMaxDiff");
_throttleTimeout = SC.GetValue<int>($"PM.{Module}.ThrottlePressureTimeout");
_ventTimeout = SC.GetValue<int>($"PM.{Module}.Clean.VentTimeout");
_pumpTimeout = SC.GetValue<int>($"PM.{Module}.Clean.PumpTimeout");
_pressureLoopCount = SC.GetValue<int>($"PM.{Module}.Clean.CycleCleanCount");
_pressureMin = SC.GetValue<double>($"PM.{Module}.Clean.PumpBasePressure");
_pressureMinDelay = SC.GetValue<int>($"PM.{Module}.Clean.PumpDelayTime");
_pressureMinTimeout = SC.GetValue<int>($"PM.{Module}.Clean.PumpTimeout");
_pressureMax = SC.GetValue<double>($"PM.{Module}.Clean.VentBasePressure");
_pressureMaxDelay = SC.GetValue<int>($"PM.{Module}.Clean.VentDelayTime");
_pressureMaxTimeout = SC.GetValue<int>($"PM.{Module}.Clean.VentTimeout");
_pmCleanTime = SC.GetValue<int>($"PM.{Module}.Clean.CleanTime");
_throttleFinalPressure = SC.GetValue<double>($"PM.{Module}.Clean.FinalPressure");
//Purge Succeed 清掉
//_pmIoInterLock.DoLidOpenRoutineSucceed = false;
//_pmIoInterLock.DoLidCloseRoutineSucceed = false;
//if (!_pmIoInterLock.SetPMCleanRoutineRunning(true, out string reason))
//{
// EV.PostAlarmLog(Module, $"can not Clean,{reason}");
// return Result.FAIL;
//}
_checkPMPt2Over1000 = false;
_checkPMPressureOver1000 = false;
_finalOpen = false;
currentPressureUpOrDown = PressureUpOrDown.None;
_swTimer.Restart();
Notify($"Start LoopCount:{_pressureLoopCount}");
return Result.RUN;
}
public override Result Monitor()
{
try
{
//CheckRoutineTimeOut();
//关闭V76,打开V75
SetIoValueByGroup((int)RoutineStep.SetV76, IoGroupName.V76, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetV75, IoGroupName.V75, true, _IoValueOpenCloseTimeout);
//旋转停止,加热停止
SetHeatEnable((int)RoutineStep.HeatEnable, false, _heatTimeOut);
SetRotationValve((int)RoutineStep.RotationEnable, _rotationCheckSpeed, false, _rotationCloseTimeout);
//3、 关闭 V72(GasBox.Vent.Pump 打开 V25(GasBox.Vent.Bypass)。
SetIoValueByGroup((int)RoutineStep.VentPumpClose, IoGroupName.VentPump, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupV25, IoGroupName.V25, true, _IoValueOpenCloseTimeout);
//4、 打开 V31H2.Supply、 V32(Ar.Supply
SetIoValueByGroup((int)RoutineStep.SetV31, IoGroupName.V31, true, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetV32, IoGroupName.V32, true, _IoValueOpenCloseTimeout);
//5、 打开 V35(H2N2.Line1)、 V36(H2N2.Line2),关闭 B/C/E/F/H/KValves,打开 D/G Valves 打开 J valve。
SetIoValueByGroup((int)RoutineStep.SetV35V36, IoGroupName.V35V36, true, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupB, IoGroupName.B, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupC, IoGroupName.C, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupE, IoGroupName.E, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupF, IoGroupName.F, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupH, IoGroupName.H, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupK, IoGroupName.K, false, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupD, IoGroupName.D, true, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupG, IoGroupName.G, true, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.SetGroupJ, IoGroupName.J, true, _IoValueOpenCloseTimeout);
//设置MFC和PC的模式
SetMfcModeToNormalByGroup((int)RoutineStep.SetMFCMode, MfcGroupName.All);
SetPcModeToNormal((int)RoutineStep.SetPCMode, _lstPcList);
//6、 M1-M17 设定为 default 值,所有 PC 设定为 default 值(PC1-PC9) M18-M40除M30\M34\M39 MFC 3s ramp 到 default 值。
SetMfcToDefaultByGroup((int)RoutineStep.SetM1toM17, MfcGroupName.M1toM17, 0);
SetPcToDefault((int)RoutineStep.SetPC, _lstPcList);
SetMfcToDefaultByGroup((int)RoutineStep.SetM18toM40, MfcGroupName.M18toM40No303439, 3);
//7、打开 EPV2等待 3s, 打开 TV enable, 压力模式,伺服压力默认设定为 0mbar
SetIoValueByGroup((int)RoutineStep.SetEPV2, IoGroupName.EPV2, true, _IoValueOpenCloseTimeout);
TimeDelay((int)RoutineStep.TimeDelay1, 3);
SetThrottleEnableAndWait((int)RoutineStep.SetTVEnable_1, _IoThrottle, 5);
SetThrottleToPressModeAndWait((int)RoutineStep.SetTVPressMode, _IoThrottle, 5);
SetThrottleToTargetAndNoWait((int)RoutineStep.SetTv1, _IoThrottle, _pressureMin);
//8、当蝶阀设定值 ramp 到 0 后,将 M18-M40除 M30\M34\M39 MFC 3s ramp 到 0
SetMfcByGroup((int)RoutineStep.Set0M18toM40, MfcGroupName.M18toM40No303439, 0, 3);
//9、等待腔体压力到 Pump Base Pressure可配置蝶阀改为位置模式开度设定 100%
WaitChamberPressDownTo((int)RoutineStep.WaitTv1, _pressureMin, _pumpTimeout);
TimeDelay((int)RoutineStep.TimeDelay2, 3);
SetThrottleToPositionMode((int)RoutineStep.SetTVPositionMode, _IoThrottle, _throttleTimeout);
TimeDelay((int)RoutineStep.TimeDelay11, 3);
SetThrottleSetPosition((int)RoutineStep.SetTVPositionMax, _IoThrottle, 100, _throttleTimeout);
//10、 M27、 M28、 M29、 M31、 M33、 M40 依次设定 3S ramp 到 default 值
SetMfcToDefaultByGroup((int)RoutineStep.SetMfcFinal2, MfcGroupName.Final2, 3);
//11、打开 V87 SHPurge.Final、 V88 OuterGas.Final、 V89 InnerGas.Final、 V90MiddleGas.Final、 V91OpticPurge.Final、 V97CarryGas.Final
SetIoValueByGroup((int)RoutineStep.OpenFinal2, IoGroupName.Final2, true, _IoValueOpenCloseTimeout);
//12、 打开 V68ChamBody.N2.Purge
SetIoValueByGroup((int)RoutineStep.SetV68, IoGroupName.GasIn1, true, _IoValueOpenCloseTimeout);
TimeDelay((int)RoutineStep.TimeDelay3, 1);
//13、 M32、 M35、 M36、 M37、 M38 依次设定 3S ramp 到 default 值
SetMfcToDefaultByGroup((int)RoutineStep.SetM32M35M37, MfcGroupName.M32M35M37, 1);
SetMfcToDefaultByGroup((int)RoutineStep.SetM36, MfcGroupName.M36, 1);
SetMfcToDefaultByGroup((int)RoutineStep.SetM38, MfcGroupName.M38, 1);
TimeDelay((int)RoutineStep.TimeDelay4, 3);
//14、打开 V92GasRingPurge.Final、 V93ChamberPurge.Final、 V95ConfinementRing.Final
//等待 950打开 V94RotationUpPurge.Final、 等待 3S打开 V96HeaterWF.Final
//蝶阀改为压力模式
SetIoValueByGroup((int)RoutineStep.SetV92V93V95, IoGroupName.V92V93V95, true, _IoValueOpenCloseTimeout);
WaitChamberPressUpTo((int)RoutineStep.WaitPressUpTo950, 950, 600);
SetIoValueByGroup((int)RoutineStep.SetV94, IoGroupName.V94, true, _IoValueOpenCloseTimeout);
TimeDelay((int)RoutineStep.TimeDelay4, 3);
SetIoValueByGroup((int)RoutineStep.SetV96, IoGroupName.V96, true, _IoValueOpenCloseTimeout);
SetThrottleToPressModeAndWait((int)RoutineStep.SetTVPressMode1, _IoThrottle, 5);
//M18 - M40除 M30\M34\M39 MFC 3s ramp 到 default 值。
//关闭 EPV2等待压力达到设定值压力达到后打开 EPV2
//M18 - M40除 M30\M34\M39 MFC 5s ramp 到 0。
//伺服压力到设定值 0可配置
SetMfcToDefaultByGroup((int)RoutineStep.FirstSetDefault_M18toM40, MfcGroupName.M18toM40No303439, 3);
SetIoValueByGroup((int)RoutineStep.FirstSetEPV2_1, IoGroupName.EPV2, false, _IoValueOpenCloseTimeout);
WaitThrottleToPressureAndSetMfcSpecial((int)RoutineStep.FirstWaitPressureUp, _IoThrottle, _pressureMax, _ventTimeout);
SetIoValueByGroup((int)RoutineStep.FirstSetEPV2_2, IoGroupName.EPV2, true, _IoValueOpenCloseTimeout);
SetMfcByGroup((int)RoutineStep.FirstSet0_M18toM40, MfcGroupName.M18toM40No303439, 0, 5);
SetThrottleToTargetAndNoWait((int)RoutineStep.FirstSetTv1, _IoThrottle, _pressureMin);
//循环开始
Loop((int)RoutineStep.StartLoop, _pressureLoopCount);
//M18 - M40除 M30\M34\M39 MFC 3s ramp 到 default 值。
//关闭 EPV2等待压力达到设定值压力达到后打开 EPV2
//M18 - M40除 M30\M34\M39 MFC 5s ramp 到 0。
//伺服压力到设定值 0可配置
//M18 - M40除 M30\M34\M39 MFC5s ramp 到 0。
//等待压力到达 0可配置
SetMfcToDefaultByGroup((int)RoutineStep.LoopSetDefault_M18toM40, MfcGroupName.M18toM40No303439, 3);
SetIoValueByGroup((int)RoutineStep.LoopSetEPV2_1, IoGroupName.EPV2, false, _IoValueOpenCloseTimeout);
WaitThrottleToPressureAndSetMfcSpecial((int)RoutineStep.LoopWaitPressureUp, _IoThrottle, _pressureMax, _ventTimeout);
SetIoValueByGroup((int)RoutineStep.LoopSetEPV2_2, IoGroupName.EPV2, true, _IoValueOpenCloseTimeout);
SetMfcByGroup((int)RoutineStep.LoopSet0_M18toM40, MfcGroupName.M18toM40No303439, 0, 5);
SetThrottleToTargetAndNoWait((int)RoutineStep.LoopSetTv1, _IoThrottle, _pressureMin);
SetMfcByGroup((int)RoutineStep.Loop2Set0_M18toM40, MfcGroupName.M18toM40No303439, 0, 5);
WaitChamberPressDownTo((int)RoutineStep.LoopWaitTv1, _pressureMin, _pumpTimeout);
EndLoop((int)RoutineStep.EndLoop);
//设置 M1-M17 3s ramp 到 default M18 - M40除 M30\M34\M39 MFC 3s ramp 到default 值。
//打开 V72(GasBox.Vent.Pump 关闭 V25(GasBox.Vent.Bypass) 反应腔压力伺服到300mbar可配置
SetMfcToDefaultByGroup((int)RoutineStep.FinishSetM1toM17, MfcGroupName.M1toM17, 3);
SetMfcToDefaultByGroup((int)RoutineStep.FinishSetM18toM40, MfcGroupName.M18toM40No303439, 3);
SetIoValueByGroup((int)RoutineStep.FinishVentPumpClose_1, IoGroupName.VentPump, true, _IoValueOpenCloseTimeout);
SetIoValueByGroup((int)RoutineStep.FinishCloseGroupV25, IoGroupName.V25, false, _IoValueOpenCloseTimeout);
SetThrottleToTargetAndNoWait((int)RoutineStep.FinishSetPressureUp2, _IoThrottle, _throttleFinalPressure);
WaitThrottleToPressureAndSetMfcSpecial((int)RoutineStep.FinishSetTVto300, _IoThrottle, _throttleFinalPressure, _pmPressureMaxDiff, _throttleTimeout);
}
catch (RoutineBreakException)
{
return Result.RUN;
}
catch (RoutineFaildException)
{
return Result.FAIL;
}
Notify($"Finished ! Elapsed time: {(int)(_swTimer.ElapsedMilliseconds / 1000)} s");
_swTimer.Stop();
SetRoutineRuningDo();
SetRoutineSuccessedDo();
return Result.DONE;
}
public override void Abort()
{
SetRoutineRuningDo();
PmDevice._ioThrottleValve.StopRamp();
PmDevice.SetMfcStopRamp(PmDevice.GetMfcListByGroupName(MfcGroupName.All));
PmDevice.SetRotationServo(0, 0);
base.Abort();
}
private void SetRoutineRuningDo()
{
//_pmIoInterLock.DoLidCloseRoutineRunning = false;
}
private void SetRoutineSuccessedDo()
{
//_pmIoInterLock.SetLidClosedRoutineSucceed(true, out string reason);
//_pmIoInterLock.DoLidOpenRoutineSucceed = false;
}
//private void CheckRoutineTimeOut()
//{
// if (_routineTimeOut > 10)
// {
// if ((int)(_swTimer.ElapsedMilliseconds / 1000) > _routineTimeOut)
// {
// EV.PostAlarmLog(Module,$"Routine TimeOut! over {_routineTimeOut} s");
// throw (new RoutineFaildException());
// }
// }
//}
}
}