<?xml version="1.0" encoding="utf-8"?>
<root system= "Sic" >
<configs name= "System" >
<config default= "Unset" name= "EquipmentName" description= "Equipment Name" max= "" min= "" paramter= "" tag= "" visible= "true" unit= "" type= "String" />
<config default= "1" name= "EquipmentNo" description= "Equipment No" max= "1000000" min= "0" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "true" name= "IsSimulatorMode" description= "Is Simulator Mode" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "IsATMMode" description= "Is ATM Mode" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "IsCycleMode" description= "Is Cycle Mode" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "3" name= "CycleCount" description= "Cycle Count" max= "10000" min= "1" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "10" name= "DefaultTrayProcessCount" description= "默认Tray盘可使用次数 " max= "100" min= "1" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "true" name= "EnablePlatformCycle" visible= "false" description= "Enable Platform Cycle" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "true" name= "IsBypassIoATMSensor" visible= "false" description= "Is Bypass IO ATM Sensor" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "30" name= "LiftMotionTimeout" description= "Lift Motion Timeout" max= "60" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "30" name= "DoorMotionTimeout" description= "Door Motion Timeout" max= "60" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "30" name= "SlitValveMotionTimeout" description= "Slit Valve Motion Timeout" max= "60" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" visible= "true" />
<config default= "true" name= "AutoAlignManualTransfer" visible= "false" description= "Auto Align Manual Transfer" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "true" name= "AutoPassCooling" visible= "false" description= "Auto Pass Cooling" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "RequestAWCDataAfterPick" visible= "false" description= "Request AWC Data After Pick" max= "0" min= "0" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "RequestAWCDataAfterPlace" visible= "false" description= "Request AWC Data After Place" max= "0" min= "0" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "1000" name= "DataCollectionInterval" description= "Data Collection Interval" max= "10000" min= "20" paramter= "" tag= "" unit= "ms" type= "Integer" />
<config default= "180" name= "LogsSaveDays" description= "Logs Save Days" max= "10000" min= "1" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "false" name= "EnableDataBaseClean" description= "Enable DataBase Clean" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "180" name= "DataKeepDays" description= "Data Keep Days" max= "10000" min= "1" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "true" name= "IsIgnoreSaveDB" description= "IO不存储到数据库" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "true" name= "RecipeCascadeLoading" visible= "false" description= "启用瀑布流方式加载Recipe" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "RecipeSaveToDB" description= "Recipe文件保存到数据库" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "false" />
<config default= "true" name= "IsPMHostSignalTower" description= "是否使用PM PLC控制三色灯;如果设定为False,则使用TM PLC控制三色灯" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "false" />
<config default= "false" name= "SingleSessionLoginMode" description= "是否启用单会话登录模式,即同一个账户同一时间仅允许一个UI登录" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "MultiProcessMode" visible= "false" description= "是否启用多机台工艺限制,即限制同一局域网内的机台同时进行工艺的数量" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "Sic17" name= "MachineName" visible= "false" description= "机台名称" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "true" name= "IgnoreMaintainTimeOutWarning" description= "维护界面是否忽略Warning提示" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "AllowTraceAOHopping" description= "是否允许追踪AO跳变" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
<config default= "true" name= "AllowTraceDOHopping" description= "是否允许追踪DO跳变" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
<configs name= "Scheduler" visible= "false" >
<config default= "15" name= "WaitLoadTimeOut" description= "Wait Load TimeOut" max= "1000" min= "1" paramter= "" tag= "" unit= "s" type= "Double" visible= "false" />
<config default= "2" name= "WaferCountBelowWhichStartNewProcessJob" description= "Wafer Count Below Which Start New Process Job" max= "25" min= "1" paramter= "" tag= "" unit= "" type= "Integer" visible= "false" />
<config default= "false" name= "CassetteFromAToB" description= "CassetteA取片做完工艺后回到另外一个Cassette" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "true" name= "IsRunInParallelMode" description= "并行模式,从CST取片时考虑两腔体效率" max= "0" min= "0" paramter= "" tag= "" unit= "" type= "Bool" />
</configs>
<configs name= "SetUp" >
<config default= "true" name= "IsTMInstalled" visible= "false" description= "Is TM Installed" max= "0" min= "0" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "true" name= "IsLoadLockInstalled" visible= "false" description= "Is LoadLock Installed" max= "0" min= "0" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "IsUnLoadInstalled" description= "Is UnLoad Installed" max= "0" min= "0" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "true" name= "IsBufferInstalled" description= "Is Buffer Installed" max= "0" min= "0" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "IsEFEMInstalled" description= "Is EFEM Installed" max= "0" min= "0" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "true" name= "IsPM1Installed" description= "Is PM1 Installed" max= "0" min= "0" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "true" name= "IsPM2Installed" description= "Is PM2 Installed" max= "0" min= "0" paramter= "" tag= "" unit= "" type= "Bool" /> `
<config default= "false" name= "IsAlignerInstalled" description= "Is Aligner Installed" max= "0" min= "0" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "IsCassetteALInstalled" description= "Is Wafer CassetteL Installed" max= "0" min= "0" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "IsCassetteARInstalled" description= "Is Wafer CassetteR Installed" max= "0" min= "0" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "IsCassetteBLInstalled" description= "Is Tray Cassette Installed" max= "0" min= "0" paramter= "" tag= "" unit= "" type= "Bool" />
</configs>
<configs name= "Recipe" >
<config default= "Sic" name= "SupportedChamberType" description= "Supported Chamber Type" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "Process" name= "SupportedProcessType" description= "Supported Process Type" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "PM1,PM2" name= "ChamberModules" description= "Chamber Modules" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "false" name= "ResetEditorPassword" description= "重置Recipe编辑器锁定密码" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "600" name= "EditorAutoLockTimeout" description= "Recipe编辑器自动锁定超时时间" max= "100000" min= "5" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "8C6976E5B5410415BDE908BD4DEE15DFB167A9C873FC4BB8A81F6F2AB448A918" name= "EditorPassword" description= "Recipe编辑器锁定密码" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
</configs>
<configs name= "SignalTower" visible= "false" >
<config default= "red=1;yellow=2;green=3;blue=4;white=5;buzzer=6" name= "Light" description= "设置灯的种类,顺序" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "System.IsAlarm=System in alarm status;System.IsIdle=System in idle status" name= "Trigger" description= "设置触发灯塔的项" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "System.IsAlarm=on,off,off,off,off;System.IsIdle=off,on,off,off,off;" name= "Value" description= "设置灯塔触发的逻辑关系" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
</configs>
<configs name= "FDC" visible= "false" >
<config default= "Process" name= "DataGroupName" description= "FDC data group" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "1000" name= "DelayTime" description= "Step Delay time before collection data" max= "10000" min= "0" paramter= "" tag= "" unit= "ms" type= "Integer" />
<config default= "100" name= "SampleInterval" description= "interval time collection sample data" max= "10000" min= "0" paramter= "" tag= "" unit= "ms" type= "Integer" />
</configs>
</configs>
<configs name= "PM" >
<config default= "30" name= "HomeTimeout" description= "Home Timeout" max= "300" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "120" name= "PrepareTransferTimeout" description= "Prepare Transfer Timeout" max= "10000" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "120" name= "HandoffTransferTimeout" description= "Handoff Transfer Timeout" max= "10000" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "120" name= "PostTransferTimeout" description= "Post Transfer Timeout" max= "10000" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "1200" name= "ProcessTimeout" visible= "false" description= "Process Timeout" max= "100000" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "1" name= "OperationResetTime" visible= "false" description= "Operation Reset Time" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Double" />
<config default= "2" name= "OperationTimeout" visible= "false" description= "Operation Timeout" max= "10000" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "960" name= "AtmPressureBase" description= "Atm Pressure Base" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "302" name= "VacuumPressureBase" description= "Vacuum Pressure Base" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" visible= "false" />
<config default= "false" name= "IsAtmIdleRoutine" visible= "false" description= "是否以Recipe的形式运行ATM Idle" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "IsVacIdleRoutine" visible= "false" description= "是否以Recipe的形式运行VAC Idle" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "IsProcessIdleRoutine" visible= "false" description= "是否Recipe的形式运行Process Idle" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "IsPumpRoutine" visible= "false" description= "是否Recipe的形式运行Pump" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "IsVentRoutine" visible= "false" description= "是否Recipe的形式运行Vent" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "IsPurgeRoutine" visible= "false" description= "是否Recipe的形式运行Purge" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "IsCleanRoutine" visible= "false" description= "是否Recipe的形式运行Clean" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "IsExchangeMOTCSRoutine" visible= "false" description= "是否Recipe的形式运行ExchangeTCS" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "IsExchangeMOTMARoutine" visible= "false" description= "是否Recipe的形式运行ExchangeTMA" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "IsIsolationRoutine" visible= "false" description= "是否Recipe的形式运行Isolation" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "IsLeakCheckRoutine" visible= "false" description= "是否Recipe的形式运行LeakCheck" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "IsAbortRoutine" visible= "false" description= "是否Recipe的形式运行Abort" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "15" name= "LidMotionTimeout" visible= "false" description= "LidMotionTimeout" max= "100" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "180" name= "LidEnableOpenAfterHeatDisbaleTime" description= "在加热停止多少分钟后才能执行开腔" max= "1000" min= "1" paramter= "" tag= "" unit= "Minute" type= "Integer" />
<config default= "620" name= "SimlatorTempThreshold" description= "加热低于该温度启用模拟降温" max= "800" min= "300" paramter= "" tag= "" unit= "℃" type= "Integer" />
<configs name= "RecipeConfig" >
<configs name= "SHFlow_SHTotalFlow" >
<configs name= "Ar/H2Switch" >
<config default= "Ar" name= "Default" description= "Default Value" max= "" min= "" paramter= "Ar;H2" tag= "ReadOnlySelection" unit= "" type= "String" visible= "true" />
</configs>
<configs name= "SHTotalFlow" >
2026-06-17 16:34:03 +08:00
<config default= "140000" name= "Default" description= "Default Value" max= "900000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
2026-03-24 15:04:02 +08:00
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
2026-06-17 16:34:03 +08:00
<config default= "900000" name= "Max" description= "Maximum Value" max= "900000" min= "200000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
2026-03-24 15:04:02 +08:00
</configs>
<configs name= "CarryGasFlow(M40)" >
<config default= "5000" name= "Default" description= "Default Value" max= "100000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "100000" name= "Max" description= "Maximum Value" max= "100000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "SHTotalFlowSplitRatio" >
<config default= "18:46:84" name= "Default" description= "Default Value" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" visible= "true" />
</configs>
<configs name= "FlowSetMode" >
<config default= "Ramp" name= "Default" description= "Default Value" max= "" min= "" paramter= "Ramp;Jump" tag= "ReadOnlySelection" unit= "" type= "String" visible= "true" />
</configs>
</configs>
<configs name= "Pressure_Rotation" >
<configs name= "PressureSet" >
<config default= "300" name= "Default" description= "Default Value" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
<config default= "1100" name= "Max" description= "Maximum Value" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
</configs>
<configs name= "RotationSet" >
<config default= "300" name= "Default" description= "Default Value" max= "1000" min= "0" paramter= "" tag= "" unit= "rpm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "rpm" type= "Integer" visible= "false" />
<config default= "1000" name= "Max" description= "Maximum Value" max= "1000" min= "1000" paramter= "" tag= "" unit= "rpm" type= "Integer" visible= "false" />
</configs>
</configs>
<configs name= "Temperature_ControlMode" >
<configs name= "PSUControlMode" >
<config default= "Power" name= "Default" description= "Default Value" max= "" min= "" paramter= "PyroAuto;PyroFollow;Power" tag= "ReadOnlySelection" unit= "" type= "String" />
</configs>
<configs name= "PSUSetMode" >
<config default= "Ramp" name= "Default" description= "Default Value" max= "" min= "" paramter= "Ramp;Jump" tag= "ReadOnlySelection" unit= "" type= "String" visible= "true" />
</configs>
<configs name= "SCRControlMode" >
<config default= "Power" name= "Default" description= "Default Value" max= "" min= "" paramter= "Pyro;Power" tag= "ReadOnlySelection" unit= "" type= "String" visible= "true" />
</configs>
<configs name= "SCRSetMode" >
<config default= "Ramp" name= "Default" description= "Default Value" max= "" min= "" paramter= "Ramp;Jump" tag= "ReadOnlySelection" unit= "" type= "String" visible= "true" />
</configs>
</configs>
<configs name= "Temperature_TempSetting" >
<configs name= "PSUInnerTempSet" >
<config default= "50" name= "Default" description= "Default Value" max= "1720" min= "0" paramter= "" tag= "" unit= "℃" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "500" min= "0" paramter= "" tag= "" unit= "℃" type= "Integer" visible= "false" />
<config default= "1720" name= "Max" description= "Maximum Value" max= "1800" min= "0" paramter= "" tag= "" unit= "℃" type= "Integer" visible= "false" />
</configs>
<configs name= "PSUMiddleTempSet" >
<config default= "0" name= "Default" description= "Default Value" max= "1720" min= "0" paramter= "" tag= "" unit= "℃" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "500" min= "0" paramter= "" tag= "" unit= "℃" type= "Integer" visible= "false" />
<config default= "1720" name= "Max" description= "Maximum Value" max= "1800" min= "0" paramter= "" tag= "" unit= "℃" type= "Integer" visible= "false" />
</configs>
<configs name= "PSUOuterTempSet" >
<config default= "0" name= "Default" description= "Default Value" max= "1720" min= "0" paramter= "" tag= "" unit= "℃" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "℃" type= "Integer" visible= "false" />
<config default= "1720" name= "Max" description= "Maximum Value" max= "1800" min= "0" paramter= "" tag= "" unit= "℃" type= "Integer" visible= "false" />
</configs>
<configs name= "SCRTempSet" >
<config default= "0" name= "Default" description= "Default Value" max= "1650" min= "0" paramter= "" tag= "" unit= "℃" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "500" min= "0" paramter= "" tag= "" unit= "℃" type= "Integer" visible= "false" />
<config default= "1650" name= "Max" description= "Maximum Value" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Integer" visible= "false" />
</configs>
<configs name= "MiddleTempRatio" >
<config default= "100" name= "Default" description= "Middle控温时温度比例" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "100" min= "0" paramter= "" tag= "" unit= "℃" type= "Integer" visible= "true" />
<config default= "100" name= "Max" description= "Maximum Value" max= "100" min= "0" paramter= "" tag= "" unit= "℃" type= "Integer" visible= "true" />
</configs>
</configs>
<configs name= "Temperature_HeaterOutput" >
<configs name= "PSUInnerRatioSet" >
<config default= "5" name= "Default" description= "Default Value" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "%" type= "Integer" visible= "false" />
<config default= "100" name= "Max" description= "Maximum Value" max= "100" min= "100" paramter= "" tag= "" unit= "%" type= "Integer" visible= "false" />
</configs>
<configs name= "PSUMiddleRatioSet" >
<config default= "16" name= "Default" description= "Default Value" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "%" type= "Integer" visible= "false" />
<config default= "100" name= "Max" description= "Maximum Value" max= "100" min= "100" paramter= "" tag= "" unit= "%" type= "Integer" visible= "false" />
</configs>
<configs name= "PSUOuterRatioSet" >
<config default= "25" name= "Default" description= "Default Value" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "%" type= "Integer" visible= "false" />
<config default= "100" name= "Max" description= "Maximum Value" max= "100" min= "100" paramter= "" tag= "" unit= "%" type= "Integer" visible= "false" />
</configs>
<configs name= "PSU2OutputLimitHigh" >
<config default= "100" name= "Default" description= "Default Value" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "%" type= "Integer" visible= "false" />
<config default= "100" name= "Max" description= "Maximum Value" max= "100" min= "100" paramter= "" tag= "" unit= "%" type= "Integer" visible= "false" />
</configs>
<configs name= "SCRUpperRatioSet" >
<config default= "12" name= "Default" description= "Default Value" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "String" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "%" type= "Integer" visible= "false" />
<config default= "100" name= "Max" description= "Maximum Value" max= "100" min= "100" paramter= "" tag= "" unit= "%" type= "Integer" visible= "false" />
</configs>
<configs name= "SCRMiddleRatioSet" >
<config default= "6" name= "Default" description= "Default Value" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "%" type= "Integer" visible= "false" />
<config default= "100" name= "Max" description= "Maximum Value" max= "100" min= "100" paramter= "" tag= "" unit= "%" type= "Integer" visible= "false" />
</configs>
<configs name= "SCRLowerRatioSet" >
<config default= "8" name= "Default" description= "Default Value" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "%" type= "Integer" visible= "false" />
<config default= "100" name= "Max" description= "Maximum Value" max= "100" min= "100" paramter= "" tag= "" unit= "%" type= "Integer" visible= "false" />
</configs>
</configs>
<configs name= "SHFlow_SiSource_SiSourceTotalFlow" >
<configs name= "SiSourceTotalFlow" >
<config default= "140000" name= "Default" description= "Default Value" max= "200000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "200000" name= "Max" description= "Maximum Value" max= "200000" min= "200000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
</configs>
<configs name= "SHFlow_SiSource_PN2Flow" >
<configs name= "PN2FlowMode" >
<config default= "Purge" name= "Default" description= "Default Value" max= "" min= "" paramter= "Purge;Vent;Run" tag= "ReadOnlySelection" unit= "" type= "String" visible= "true" />
</configs>
<configs name= "PN2Flow(M14)" >
<config default= "25" name= "Default" description= "Default Value" max= "500" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "50" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" visible= "false" />
<config default= "500" name= "Max" description= "Maximum Value" max= "500" min= "500" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
</configs>
<configs name= "SHFlow_SiSource_TCSFlow" >
<configs name= "TCSFlowMode" >
<config default= "Purge" name= "Default" description= "Default Value" max= "" min= "" paramter= "Purge;Vent;Run" tag= "ReadOnlySelection" unit= "" type= "String" visible= "true" />
</configs>
<configs name= "TCSBubbLowFlow(M11)" >
<config default= "50" name= "Default" description= "Default Value" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "100" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "1000" name= "Max" description= "Maximum Value" max= "1000" min= "1000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "TCSBubbHighFlow(M10)" >
<config default= "150" name= "Default" description= "Default Value" max= "5000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "500" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "5000" name= "Max" description= "Maximum Value" max= "5000" min= "5000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "TCSPushFlow(M12)" >
<config default= "100" name= "Default" description= "Default Value" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "100" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "1000" name= "Max" description= "Maximum Value" max= "1000" min= "1000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "TCSBubbPressure(PC3)" >
<config default= "1900" name= "Default" description= "Default Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "500" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
<config default= "3000" name= "Max" description= "Maximum Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
</configs>
</configs>
<configs name= "SHFlow_SiSource_HClFlow" >
<configs name= "HClFlowMode " >
<config default= "Purge" name= "Default" description= "Default Value" max= "" min= "" paramter= "Purge;Vent;Run" tag= "ReadOnlySelection" unit= "" type= "String" visible= "true" />
</configs>
<configs name= "HClFlow(M13)" >
<config default= "100" name= "Default" description= "Default Value" max= "5000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "500" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "5000" name= "Max" description= "Maximum Value" max= "5000" min= "5000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
</configs>
<configs name= "SHFlow_SiSource_SiSourceSplit" >
<configs name= "SiSourceSplitRatio" >
<config default= "18:46:84" name= "Default" description= "Default Value" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" visible= "true" />
</configs>
<configs name= "SiSourcePushPressure(PC6)" >
<config default= "1260" name= "Default" description= "Default Value" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "3000" name= "Max" description= "Maximum Value" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "SiSourceInnerFlow(M23)" >
<config default= "1500" name= "Default" description= "Default Value" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "0" name= "Min" description= "Minimum Value" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "10000" name= "Max" description= "Maximum Value" max= "10000" min= "10000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "SiSourceMiddleFlow(M22)" >
<config default= "3000" name= "Default" description= "Default Value" max= "20000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "0" name= "Min" description= "Minimum Value" max= "2000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "20000" name= "Max" description= "Maximum Value" max= "20000" min= "20000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "SiSourceOuterFlow(M9)" >
<config default= "1500" name= "Default" description= "Default Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
<config default= "0" name= "Min" description= "Minimum Value" max= "1000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
<config default= "10000" name= "Max" description= "Maximum Value" max= "10000" min= "10000" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
</configs>
</configs>
<configs name= "SHFlow_CSource_CSourceTotalFlow" >
<configs name= "CSourceTotalFlow" >
<config default= "8000" name= "Default" description= "Default Value" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "1000000" name= "Max" description= "Maximum Value" max= "1000000" min= "1000000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
</configs>
<configs name= "SHFlow_CSource_C2H4Flow" >
<configs name= "C2H4FlowMode " >
<config default= "Purge" name= "Default" description= "Default Value" max= "" min= "" paramter= "Purge;Vent;Run" tag= "ReadOnlySelection" unit= "" type= "String" visible= "true" />
</configs>
<configs name= "C2H4Flow(M16)" >
<config default= "25" name= "Default" description= "Default Value" max= "500" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "50" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" visible= "false" />
<config default= "500" name= "Max" description= "Maximum Value" max= "500" min= "500" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<!--<configs name="V99 "><config default="Purge" name="Default" description="Default Value" max="" min="" paramter="Purge;Vent" tag="ReadOnlySelection" unit="" type="String" visible="true" /></configs><configs name="BalanceCFlow"><config default="3" name="Default" description="Default Value" max="50" min="0" paramter="" tag="" unit="sccm" type="Integer" visible="true" /><config default="0.75" name="Min" description="Minimum Value" max="10" min="0" paramter="" tag="" unit="sccm" type="Double" visible="false" /><config default="50" name="Max" description="Maximum Value" max="50" min="50" paramter="" tag="" unit="sccm" type="Integer" visible="false" /></configs>-->
</configs>
<configs name= "SHFlow_CSource_CSourceSplit" >
<configs name= "CSourceSplitRatio" >
<config default= "18:46:84" name= "Default" description= "Default Value" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" visible= "true" />
</configs>
<configs name= "CSourcePushPressure(PC7)" >
<config default= "1260" name= "Default" description= "Default Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
<config default= "3000" name= "Max" description= "Maximum Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
</configs>
<configs name= "CSourceInnerFlow(M26)" >
<config default= "1500" name= "Default" description= "Default Value" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "0" name= "Min" description= "Minimum Value" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "10000" name= "Max" description= "Maximum Value" max= "10000" min= "10000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "CSourceMiddleFlow(M25)" >
<config default= "3000" name= "Default" description= "Default Value" max= "20000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "0" name= "Min" description= "Minimum Value" max= "2000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "20000" name= "Max" description= "Maximum Value" max= "20000" min= "20000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "CSourceOuterFlow(M15)" >
<config default= "1500" name= "Default" description= "Default Value" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "0" name= "Min" description= "Minimum Value" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "10000" name= "Max" description= "Maximum Value" max= "10000" min= "10000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
</configs>
<configs name= "SHFlow_Dope_DopeTotalFlow" >
<configs name= "DopeTotalFlow" >
<config default= "1000" name= "Default" description= "Default Value" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "1000000" name= "Max" description= "Maximum Value" max= "1000000" min= "1000000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
</configs>
<configs name= "SHFlow_Dope_N2Flow" >
<configs name= "N2FlowMode" >
<config default= "Purge" name= "Default" description= "Default Value" max= "" min= "" paramter= "Purge;Vent;Run" tag= "ReadOnlySelection" unit= "" type= "String" visible= "true" />
</configs>
<configs name= "HN3FlowMode" >
<config default= "Purge" name= "Default" description= "Default Value" max= "" min= "" paramter= "Purge;Vent;Run" tag= "ReadOnlySelection" unit= "" type= "String" visible= "true" />
</configs>
<configs name= "N2ActualFlow" >
<config default= "25" name= "Default" description= "Default Value" max= "500" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" visible= "false" />
<config default= "1000000" name= "Max" description= "Maximum Value" max= "1000000" min= "1000000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "NH3ActualFlow" >
<config default= "25" name= "Default" description= "Default Value" max= "500" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" visible= "false" />
<config default= "1000000" name= "Max" description= "Maximum Value" max= "1000000" min= "1000000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "N2LowFlow(M4)" >
<config default= "50" name= "Default" description= "Default Value" max= "500" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "50" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" visible= "false" />
<config default= "500" name= "Max" description= "Maximum Value" max= "500" min= "500" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "NH3LowFlow(M4)" >
<config default= "50" name= "Default" description= "Default Value" max= "500" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "50" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" visible= "false" />
<config default= "500" name= "Max" description= "Maximum Value" max= "500" min= "500" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "DilutFlowForN2(M3)" >
<config default= "200" name= "Default" description= "Default Value" max= "5000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "500" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "5000" name= "Max" description= "Maximum Value" max= "5000" min= "5000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "DilutFlowForNH3(M3)" >
<config default= "200" name= "Default" description= "Default Value" max= "5000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "500" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "5000" name= "Max" description= "Maximum Value" max= "5000" min= "5000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "DilutedN2Flow(M6)" >
<config default= "75" name= "Default" description= "Default Value" max= "500" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "0" name= "Min" description= "Minimum Value" max= "50" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" visible= "false" />
<config default= "500" name= "Max" description= "Maximum Value" max= "500" min= "500" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "DilutedNH3Flow(M6)" >
<config default= "125" name= "Default" description= "Default Value" max= "500" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "50" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" visible= "false" />
<config default= "500" name= "Max" description= "Maximum Value" max= "500" min= "500" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "N2PostDilutPressure(PC1)" >
<config default= "1500" name= "Default" description= "Default Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
<config default= "3000" name= "Max" description= "Maximum Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
</configs>
<configs name= "NH3PostDilutPressure(PC1)" >
<config default= "1500" name= "Default" description= "Default Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
<config default= "3000" name= "Max" description= "Maximum Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
</configs>
<configs name= "N2HighFlowMode" >
<config default= "Purge" name= "Default" description= "Default Value" max= "" min= "" paramter= "Purge;Vent;Run" tag= "ReadOnlySelection" unit= "" type= "String" visible= "true" />
</configs>
<configs name= "N2FlowMode" >
<config default= "Purge" name= "Default" description= "Default Value" max= "" min= "" paramter= "Purge;Vent;Run" tag= "ReadOnlySelection" unit= "" type= "String" visible= "true" />
</configs>
<configs name= "N2HighFlow(M5)" >
<config default= "380" name= "Default" description= "Default Value" max= "20000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "2000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "20000" name= "Max" description= "Maximum Value" max= "20000" min= "20000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "N2Flow(M5)" >
<config default= "380" name= "Default" description= "Default Value" max= "20000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "2000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "20000" name= "Max" description= "Maximum Value" max= "20000" min= "20000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
</configs>
<configs name= "SHFlow_Dope_TMAFlow" >
<configs name= "TMAFlowMode " >
<config default= "Purge" name= "Default" description= "Default Value" max= "" min= "" paramter= "Purge;Vent;Run" tag= "ReadOnlySelection" unit= "" type= "String" visible= "true" />
</configs>
<configs name= "TMABubbFlow(M7)" >
<config default= "50" name= "Default" description= "Default Value" max= "500" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "50" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" visible= "false" />
<config default= "500" name= "Max" description= "Maximum Value" max= "500" min= "500" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "TMAPushFlow(M8)" >
<config default= "50" name= "Default" description= "Default Value" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "100" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "1000" name= "Max" description= "Maximum Value" max= "1000" min= "1000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "TMABubbPressure(PC2)" >
<config default= "900" name= "Default" description= "Default Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
<config default= "3000" name= "Max" description= "Maximum Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
</configs>
</configs>
<configs name= "SHFlow_Dope_DopeSplit" >
<configs name= "DopeSplitRatio" >
<config default= "18:46:84" name= "Default" description= "Default Value" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" visible= "true" />
</configs>
<configs name= "DopePushPressure(PC5)" >
<config default= "1500" name= "Default" description= "Default Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
<config default= "3000" name= "Max" description= "Maximum Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
</configs>
<configs name= "DopeInnerFlow(M20)" >
<config default= "1500" name= "Default" description= "Default Value" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "0" name= "Min" description= "Minimum Value" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "10000" name= "Max" description= "Maximum Value" max= "10000" min= "10000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "DopeMiddleFlow(M19)" >
<config default= "3000" name= "Default" description= "Default Value" max= "20000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "0" name= "Min" description= "Minimum Value" max= "2000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "20000" name= "Max" description= "Maximum Value" max= "20000" min= "20000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "DopeOuterFlow(M2)" >
<config default= "1500" name= "Default" description= "Default Value" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "0" name= "Min" description= "Minimum Value" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "10000" name= "Max" description= "Maximum Value" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
</configs>
<configs name= "SHFlow_SHPushFlow" >
<configs name= "SHPushTotalFlow" >
<config default= "0" name= "Default" description= "Default Value" max= "100000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "1000000" name= "Max" description= "Maximum Value" max= "1000000" min= "1000000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "SHInnerFlow" >
<config default= "0" name= "Default" description= "Default Value" max= "100000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "1000000" name= "Max" description= "Maximum Value" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "SHMiddleFlow" >
<config default= "0" name= "Default" description= "Default Value" max= "100000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "1000000" name= "Max" description= "Maximum Value" max= "1000000" min= "1000000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "SHOuterFlow" >
<config default= "0" name= "Default" description= "Default Value" max= "100000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "1000000" name= "Max" description= "Maximum Value" max= "1000000" min= "1000000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "InnerPushFlow(M29)" >
<config default= "15000" name= "Default" description= "Default Value" max= "100000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "0" name= "Min" description= "Minimum Value" max= "100000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "100000" name= "Max" description= "Maximum Value" max= "100000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "MiddlePushFlow(M31)" >
<config default= "4500" name= "Default" description= "Default Value" max= "30000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "0" name= "Min" description= "Minimum Value" max= "3000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "30000" name= "Max" description= "Maximum Value" max= "30000" min= "30000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "OuterPushFlow(M28)" >
<config default= "7500" name= "Default" description= "Default Value" max= "50000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "0" name= "Min" description= "Minimum Value" max= "50000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "50000" name= "Max" description= "Maximum Value" max= "50000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
</configs>
<configs name= "Purge_SHPeripheryPurge" >
<configs name= "SHPurgeFlow(M27)" >
<config default= "2000" name= "Default" description= "Default Value" max= "50000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" />
<config default= "0" name= "Min" description= "Minimum Value" max= "100000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "50000" name= "Max" description= "Maximum Value" max= "100000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "OpticPurgeFlow(M33)" >
<config default= "500" name= "Default" description= "Default Value" max= "5000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "500" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "5000" name= "Max" description= "Maximum Value" max= "5000" min= "5000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
</configs>
<configs name= "Purge_ChamberPeripheryPurge" >
<configs name= "GasRingPurgeFlow(M32)" >
<config default= "800" name= "Default" description= "Default Value" max= "20000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "2000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "20000" name= "Max" description= "Maximum Value" max= "20000" min= "20000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "ChamberPurgeFlow(M35)" >
<config default= "1000" name= "Default" description= "Default Value" max= "30000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "3000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "30000" name= "Max" description= "Maximum Value" max= "30000" min= "30000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "RotationUpPurgeFlow(M36)" >
<config default= "1000" name= "Default" description= "Default Value" max= "30000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "3000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "30000" name= "Max" description= "Maximum Value" max= "30000" min= "30000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "ShutterPurgeFlow(M37)" >
<config default= "600" name= "Default" description= "Default Value" max= "20000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "20000" name= "Max" description= "Maximum Value" max= "20000" min= "20000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "HeaterWFPurgeFlow(M38)" >
<config default= "1000" name= "Default" description= "Default Value" max= "20000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "3000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "20000" name= "Max" description= "Maximum Value" max= "20000" min= "20000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
</configs>
<configs name= "Purge_VentFlow" >
<configs name= "TotalVentFlow" >
<config default= "2000" name= "Default" description= "Default Value" max= "20000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "9999999" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "1000000" name= "Max" description= "Maximum Value" max= "9999999" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "VentPushFlow(M1)" >
<config default= "1500" name= "Default" description= "Default Value" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "0" name= "Min" description= "Minimum Value" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "10000" name= "Max" description= "Maximum Value" max= "10000" min= "10000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "VentPreExhaustPressure(PC4)" >
<config default= "1200" name= "Default" description= "Default Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
<config default= "3000" name= "Max" description= "Maximum Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
</configs>
<configs name= "VentPreExhaustPressure(PC9)" >
<config default= "1200" name= "Default" description= "Default Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
<config default= "3000" name= "Max" description= "Maximum Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
</configs>
<configs name= "VentPushFlow(M17)" >
<config default= "1500" name= "Default" description= "Default Value" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "0" name= "Min" description= "Minimum Value" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "10000" name= "Max" description= "Maximum Value" max= "10000" min= "10000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "VentPushFlow(M18)" >
<config default= "1500" name= "Default" description= "Default Value" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "0" name= "Min" description= "Minimum Value" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "10000" name= "Max" description= "Maximum Value" max= "10000" min= "10000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "PN2BubbPressure(PC8)" >
<config default= "1200" name= "Default" description= "Default Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
<config default= "3000" name= "Max" description= "Maximum Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
</configs>
<configs name= "Pressure(PC8)" >
<config default= "1200" name= "Default" description= "Default Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
<config default= "3000" name= "Max" description= "Maximum Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
</configs>
<configs name= "Pressure(PC9)" >
<config default= "1200" name= "Default" description= "Default Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
<config default= "3000" name= "Max" description= "Maximum Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
</configs>
</configs>
<configs name= "Add_New" >
<configs name= "PN2Flow(M30)" >
<config default= "1500" name= "Default" description= "Default Value" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "0" name= "Min" description= "Minimum Value" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
<config default= "10000" name= "Max" description= "Maximum Value" max= "10000" min= "10000" paramter= "" tag= "" unit= "sccm" type= "Integer" visible= "false" />
</configs>
<configs name= "Pressure(PC8)" >
<config default= "1200" name= "Default" description= "Default Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "true" />
<config default= "0" name= "Min" description= "Minimum Value" max= "0" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
<config default= "3000" name= "Max" description= "Maximum Value" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Integer" visible= "false" />
</configs>
</configs>
</configs>
<configs name= "PM1" >
<config default= "PM1" name= "DisplayName" description= "PM自定义名称" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "#00FFFFFF" name= "BackgroundColor" description= "PM页面自定义背景色" max= "" min= "" paramter= "" tag= "" unit= "" type= "Color" />
2026-03-24 17:33:10 +08:00
<config default= "PN2" name= "OperationView" description= "PM气路图界面" max= "" min= "" paramter= "PN2" tag= "ReadOnlySelection" unit= "" type= "String" />
2026-03-24 15:04:02 +08:00
<config default= "false" name= "BypassInterlock" description= "Bypass Interlock" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "BypassEnableTable" description= "Bypass EnableTable" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "Sic" visible= "false" name= "RecipeChamberType" description= "Recipe Chamber Type" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "" name= "LastRecipeName" description= "last recipe name" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "127.0.01:102" name= "SiemensIP" description= "Siemens IP Address,Default IP:192.168.1.105:102" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "S1500" visible= "false" name= "SiemensType" description= "Siemens Type" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "30" name= "PT1PT2PressureDifferenceUpperLimit" description= "PT1和PT2最大压差上限" max= "1100" min= "0" paramter= "" tag= "" unit= "s" type= "Double" />
<config default= "Warning" name= "PT1PT2PressureDifferenceMaxAlarmLevel" description= "工艺过程中PT1和PT2最大压差超限时产生报警的等级" max= "" min= "" paramter= "Alarm;Warning" tag= "ReadOnlySelection" unit= "" type= "String" />
<config default= "5" name= "ThrottlePressureMaxDiff" description= "蝶阀调节值与实际压力的差值小于此数值则表示到位" max= "1000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "120" name= "ThrottlePressureTimeout" description= "蝶阀调节值超时时间" max= "2000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "5" name= "ThrottlePressureRate" description= "蝶阀每秒调节速率(mbar/每秒)" max= "1000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "5" name= "ThrottlePositionRate" description= "蝶阀每秒调节速率(百分比/每秒)" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
<config default= "300" visible= "false" name= "RotationCloseTimeout" description= "关闭旋转超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "0" name= "ThrottlePositionDefaultValue" description= "蝶阀位置模式默认值" max= "100" min= "0" paramter= "" tag= "" unit= "s" type= "Double" />
<config default= "1100" name= "ThrottlePressureDefaultValue" description= "蝶阀压力模式默认值" max= "1500" min= "0" paramter= "" tag= "" unit= "s" type= "Double" />
<config default= "400" name= "ThrottlePositionModeMaxPressure" description= "蝶阀允许位置模式需要的最大压力值" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
2026-06-05 17:08:52 +08:00
<config default= "1000*10,3000*10,3000*10,4000*10,6000*10,8000*10,10000*10,12000*10,14000*10,2500*10" name= "MFC27DynamicFlow" description= "MFC27 动态流量" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
2026-03-24 15:04:02 +08:00
<config default= "1000*10,3000*10,3000*10,4000*10,6000*10,8000*10,10000*10,12000*10,14000*10,2500*10" name= "MFC28DynamicFlow" description= "MFC28 动态流量" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "500*10,2000*10,2500*10,3500*10,5500*10,7500*10,9500*10,11500*10,13000*10,2000*10" name= "MFC29DynamicFlow" description= "MFC29 动态流量" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "1000*10,3000*10,5000*10,6000*10,8000*10,10000*10,12000*10,14000*10,16000*10,4000*10" name= "MFC31DynamicFlow" description= "MFC31 动态流量" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
2026-06-05 17:08:52 +08:00
<config default= "4000*10,7000*10,11000*10,13000*10,16000*10,19000*10,23000*10,28000*10,34000*10,11000*10" name= "MFC35DynamicFlow" description= "MFC35 动态流量" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
2026-03-24 15:04:02 +08:00
<config default= "4000*10,7000*10,11000*10,13000*10,16000*10,19000*10,23000*10,28000*10,34000*10,11000*10" name= "MFC40DynamicFlow" description= "MFC40 动态流量" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
2026-06-05 17:08:52 +08:00
<config default= "4000*10,7000*10,11000*10,13000*10,16000*10,19000*10,23000*10,28000*10,34000*10,11000*10" name= "MFC41DynamicFlow" description= "MFC41 动态流量" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "4000*10,7000*10,11000*10,13000*10,16000*10,19000*10,23000*10,28000*10,34000*10,11000*10" name= "MFC42DynamicFlow" description= "MFC42 动态流量" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
2026-03-24 15:04:02 +08:00
<config default= "false" name= "PreTransferPSUEnable" description= "传盘是否开启PSU加热" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "true" name= "PreTransferSCREnable" description= "传盘是否开启SCR加热" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "ReactorSuspectorCheckEnable" description= "传盘后是否检查ReactorSuspectorCheck Sensor" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "50" name= "ReactorPressRisingRateLimit" description= "腔体压力上升速率超速报警" max= "1000" min= "0" paramter= "" tag= "" unit= "mbar/s" type= "Double" />
<config default= "1020" name= "PressureForV27ForceOpen" description= "Pressure For V27 Switch" max= "1150" min= "850" paramter= "" tag= "" unit= "mbar" type= "Double" visible= "false" />
<config default= "960" name= "PressureForV27ForceClose" description= "Pressure For V27 Switch" max= "1150" min= "850" paramter= "" tag= "" unit= "mbar" type= "Double" visible= "false" />
<config default= "20" name= "TCSFluidInfusionTime" description= "TCS补液时间" max= "600" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "false" name= "TCSFluidInfusionFeedbackDI" description= "TCS补液使用DI反馈信号控制" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "Sic\Routine\ATMIdle" name= "AtmIdleFileName" description= "ATM Idle Routine文件路径" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "Sic\Routine\VACIdle" name= "VacIdleFileName" description= "VAC Idle Routine文件路径" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "Sic\Routine\ProcessIdle" name= "ProcessIdleFileName" description= "Process Idle Routine文件路径" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "Sic\Routine\Pump" name= "PumpFileName" description= "Pump Routine文件路径" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "Sic\Routine\Vent" name= "VentFileName" description= "Vent Routine文件路径" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "Sic\\Routine\Purge" name= "PurgeFileName" description= "Purge Routine文件路径" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "Sic\\Routine\Clean" name= "CleanFileName" description= "Clean Routine文件路径" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "Sic\Routine\ExchangeMOTCS" name= "ExchangeMOTCSFileName" description= "ExchangeTCS Routine文件路径" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "Sic\Routine\ExchangeMOTMA" name= "ExchangeMOTMAFileName" description= "ExchangeTMA Routine文件路径" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "Sic\Routine\Isolation" name= "IsolationFileName" description= "Isolation Routine文件路径" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "Sic\Routine\LeakCheck" name= "LeakCheckFileName" description= "LeakCheck Routine文件路径" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "Sic\Routine\Abort" name= "AbortFileName" description= "Abort Routine文件路径" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "" name= "OpenLidCountDownTime" visible= "false" description= "临时保存开腔倒计时开始时间" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "TMAEnable" description= "TMA是否选装" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "C2H4" name= "CarbonSource" description= "碳源类型,C2H4、C3H8" max= "" min= "" paramter= "C2H4;C3H8" tag= "ReadOnlySelection" unit= "" type= "String" />
<config default= "true" name= "ShutDownPLC" description= "选择否关软件后很快就关闭加热,PLC走宕机流程" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<configs name= "Heater" >
<config default= "false" name= "PSUOuterAutoEnable" description= "PSU Outer是否为Auto控制" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "false" />
<config default= "10" name= "TempRampRate" description= "TC温度每秒调节速率(℃/每秒)" max= "100" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "0.1" name= "AmpereRampRate" description= "TC1功率每秒调节速率(%/每秒)" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
<config default= "0.1" name= "KWRampRate" description= "TC2功率每秒调节速率(%/每秒)" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
<config default= "20" name= "PyroWarmEffectFromTime" description= "Pyro温度报警在进入Process状态下多久才有效" max= "1800" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "20" name= "PyroWarmEffectEndTime" description= "Pyro温度报警在结束Process状态前多久才有效" max= "1800" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "50" name= "PyroWarmMaxDiff" description= "Pyro的MidlleTemp,OuterTemp任意两个温度差大于此数值需要报警" max= "1000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "900" name= "PyroWarmBaseTemp" visible= "false" description= "Pyro温度报警需要满足BaseTemp" max= "2000" min= "200" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "true" name= "PyroWarmIsAlarm" visible= "false" description= "Pyro温度差过大报警类型为Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "1700" name= "PSUTempHighLimit" description= "PSU Temp High Limit(℃)" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "600" name= "PSUTempLowLimit" description= "PSU Temp Low Limit(℃)" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "1700" name= "SCRTempHighLimit" visible= "false" description= "SCR Temp High Limit(℃)" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "900" name= "SCRTempLowLimit" visible= "false" description= "SCR Temp Low Limit(℃)" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "0.5" name= "PSU1ResistanceMax" description= "Max PSU Inner Resistance Max Limit" max= "1000" min= "0" paramter= "" tag= "" unit= "Ω" type= "Double" />
<config default= "0.5" name= "PSU2ResistanceMax" description= "Max PSU Middle Resistance Max Limit" max= "1000" min= "0" paramter= "" tag= "" unit= "Ω" type= "Double" />
<config default= "0.5" name= "PSU3ResistanceMax" description= "Max PSU Outer Resistance Max Limit" max= "1000" min= "0" paramter= "" tag= "" unit= "Ω" type= "Double" />
<config default= "0.5" name= "SCR1ResistanceMax" description= "Max SCR Upper Resistance Max Limit" max= "1000" min= "0" paramter= "" tag= "" unit= "Ω" type= "Double" />
<config default= "0.5" name= "SCR2ResistanceMax" description= "Max SCR Middle Resistance Max Limit" max= "1000" min= "0" paramter= "" tag= "" unit= "Ω" type= "Double" />
<config default= "0.5" name= "SCR3ResistanceMax" description= "Max SCR Lower Resistance Max Limit" max= "1000" min= "0" paramter= "" tag= "" unit= "Ω" type= "Double" />
<config default= "5" name= "ResistanceMonitorHysteresis" description= "电阻检测迟滞时间,当电阻持续超限指定时间后,再产生报警" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "Warning" name= "InProcessResistanceFailAlarmLevel" description= "工艺过程中检测到电阻超限时产生报警的等级" max= "" min= "" paramter= "Alarm;Warning" tag= "ReadOnlySelection" unit= "" type= "String" />
<config default= "20" name= "InProcessResistanceMonitorIgnoreDuration" description= "工艺启动后和结束前的指定时间内忽略电阻超限检查" max= "100" min= "0" paramter= "" tag= "" unit= "s" type= "Double" visible= "false" />
<config default= "0" name= "PIDLimitLower" description= "Pyro模式PID整定限幅下限" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "100" name= "PIDLimitUpper" description= "Pyro模式PID整定限幅上限" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "4" name= "PIDRateLimit" description= "Pyro模式PID整定输出幅度变化速率" max= "100" min= "1" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "false" name= "AETempRasingFastIsAlarm" description= "AETemp温度上升过快报警类型为Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "100" visible= "false" name= "SCRTempRasingRate" description= "SCRTemp每秒的上升速率,超过此范围报警" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "20" name= "AETempMiddleRasingRate" description= "AETemp Middle每秒的上升速率,超过此范围报警" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "20" name= "AETempOuterRasingRate" description= "AETemp Outer每秒的上升速率,超过此范围报警" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<!--<config default="5" name="AETempFrequency" description="AETemp 采样频率" max="300" min="0" paramter="" tag="" unit="s" type="Double" />-->
<config default= "850" name= "PlacePVTempLimit" description= "往PM放盘时,需要等待温度低于此数值" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "900" name= "PickPVTempLimit" description= "从PM取盘时,需要等待温度低于此数值" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "1.0" name= "PSU1Y" description= "底部恒功率模式控制方案PSU1百分比" max= "99999" min= "0" paramter= "" tag= "" unit= "" visible= "false" type= "Double" />
<config default= "1.0" name= "PSU2Y" description= "底部恒功率模式控制方案PSU2百分比" max= "99999" min= "0" paramter= "" tag= "" unit= "" visible= "false" type= "Double" />
<config default= "1.0" name= "PSU3Y" description= "底部恒功率模式控制方案PSU3百分比" max= "99999" min= "0" paramter= "" tag= "" unit= "" visible= "false" type= "Double" />
<config default= "0.5" name= "PSU1Power" description= "底部恒功率模式控制方案PSU1功率" max= "99999" min= "0" paramter= "" tag= "" unit= "" visible= "false" type= "Double" />
<config default= "6.0" name= "PSU2Power" description= "底部恒功率模式控制方案PSU2功率" max= "99999" min= "0" paramter= "" tag= "" unit= "" visible= "false" type= "Double" />
<config default= "6.0" name= "PSU3Power" description= "底部恒功率模式控制方案PSU3功率" max= "99999" min= "0" paramter= "" tag= "" unit= "" visible= "false" type= "Double" />
<config default= "25" name= "PyroDiffWarning" description= "Pyro控温时,温差超过此值时警告" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "50" name= "PyroDiffAlarm" description= "Pyro控温时,温差超过此值时报警" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "120" name= "PyroDiffCheckDelay" description= "进入Pyro控温后,延迟当前设置时间后开始监测温差" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Double" visible= "false" />
<config default= "3000" name= "PyroDiffFilterTime" description= "Pyro控温时,温差警告或报警的滤波时间" max= "10000" min= "0" paramter= "" tag= "" unit= "ms" type= "Double" />
<!--
<config default="false" name="PSU2OutputLimitHighTuningByRecipe" description="PSU2输出限幅上限值由Recipe调节" max="" min="" paramter="" tag="" unit="" type="Bool" visible="false" />
<config default="1600" name="PSU2OutputLimitHighTuningTemp" description="PSU2输出限幅上限值生效温度" max="2500" min="0" paramter="" tag="" unit="" visible="false" type="Double" />
<config default="100" name="PSU2OutputLimitHigh" description="PSU2输出限幅上限值" max="100" min="0" paramter="" tag="" unit="" visible="false" type="Double" />
<config default="0" name="PSU2OutputLimitLow" description="PSU2输出限幅下限值" max="100" min="0" paramter="" tag="" unit="" visible="false" type="Double" />
-->
</configs>
<configs name= "PowerDetection" >
<configs name= "PSU1Power" >
<config default= "25" name= "MaxPower" description= "最大功率KW" max= "1000" min= "0" paramter= "" tag= "" unit= "KW" type= "Double" />
<config default= "99" name= "MaxHighPowerPercent" description= "最大功率输出,连续2秒超过设定值报警,设0为禁用," max= "1000" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
</configs>
<configs name= "PSU2Power" >
<config default= "25" name= "MaxPower" description= "最大功率KW" max= "1000" min= "0" paramter= "" tag= "" unit= "KW" type= "Double" />
<config default= "99" name= "MaxHighPowerPercent" description= "最大功率输出,连续2秒超过设定值报警,设0为禁用" max= "1000" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
</configs>
<configs name= "PSU3Power" >
<config default= "25" name= "MaxPower" description= "最大功率KW" max= "1000" min= "0" paramter= "" tag= "" unit= "KW" type= "Double" />
<config default= "99" name= "MaxHighPowerPercent" description= "最大功率输出,连续2秒超过设定值报警,设0为禁用" max= "1000" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
</configs>
<configs name= "SCR1Power" >
<config default= "25" name= "MaxPower" description= "最大功率KW" max= "1000" min= "0" paramter= "" tag= "" unit= "KW" type= "Double" />
<config default= "99" name= "MaxHighPowerPercent" description= "最大功率输出,连续2秒超过设定值报警,设0为禁用," max= "1000" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
</configs>
<configs name= "SCR2Power" >
<config default= "25" name= "MaxPower" description= "最大功率KW" max= "1000" min= "0" paramter= "" tag= "" unit= "KW" type= "Double" />
<config default= "99" name= "MaxHighPowerPercent" description= "最大功率输出,连续2秒超过设定值报警,设0为禁用" max= "1000" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
</configs>
<configs name= "SCR3Power" >
<config default= "25" name= "MaxPower" description= "最大功率KW" max= "1000" min= "0" paramter= "" tag= "" unit= "KW" type= "Double" />
<config default= "99" name= "MaxHighPowerPercent" description= "最大功率输出,连续2秒超过设定值报警,设0为禁用" max= "1000" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
</configs>
</configs>
<configs name= "ITAUPSA" >
<config default= "false" name= "EnableDevice" description= "PM1 UPSA install" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "192.168.1.106" name= "Address" description= "PM1 UPSA address 192.168.1.106" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "1" name= "DeviceAddress" description= "PM1 UPSA device address" max= "1000" min= "0" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "false" name= "EnableLogMessage" description= "PM1 UPSA log message" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
</configs>
<configs name= "ITAUPSB" >
<config default= "false" name= "EnableDevice" description= "PM1 UPSB install" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "192.168.1.116" name= "Address" description= "PM1 UPSB address 192.168.1.116" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "1" name= "DeviceAddress" description= "PM1 UPSB device address" max= "1000" min= "0" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "false" name= "EnableLogMessage" description= "PM1 UPSB log message" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
</configs>
<configs name= "EATONUPS" >
<config default= "false" name= "EnableDevice" description= "PM1 EATONUPS install" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "192.168.1.106" name= "Address" description= "PM1 EATONUPS address 192.168.1.106" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "1" name= "DeviceAddress" description= "PM1 EATONUPS device address" max= "1000" min= "0" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "false" name= "EnableLogMessage" description= "PM1 EATONUPS log message" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
</configs>
<configs name= "ProcessIdle" >
<config default= "10" name= "RotationSpeed" description= "电机设置转速" max= "1000" min= "0" paramter= "" tag= "" unit= "rpm" type= "Integer" />
<config default= "200" name= "FinalPressure" description= "最后保持的压力" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "10" name= "PressureBalanceTime" description= "压力平衡时间" max= "100" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "true" name= "PSUHeaterEnable" description= "PSU加热是否启用" max= "" min= "" paramter= "" tag= "" unit= "" visible= "true" type= "Bool" />
<config default= "0" name= "PSUHeaterMode" description= "PSU HeatMode:0为Power,1为Pyro" max= "1" min= "0" paramter= "" tag= "" unit= "" type= "Integer" visible= "false" />
<config default= "5" name= "PSUInnerRatio" description= "PSU Inner Ratio" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
<config default= "16" name= "PSUMiddleRatio" description= "PSU Middle Ratio" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
<config default= "25" name= "PSUOuterRatio" description= "PSU Outer Ratio" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
<config default= "true" name= "SCRHeaterEnable" description= "SCR加热是否启用" max= "" min= "" paramter= "" tag= "" unit= "" visible= "true" type= "Bool" />
<config default= "0" name= "SCRHeaterMode" description= "SCR HeatMode:0为Power,1为Pyro" max= "1" min= "0" paramter= "" tag= "" unit= "" type= "Integer" visible= "false" />
<config default= "12" name= "SCRUpperRatio" description= "SCR Upper Ratio" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
<config default= "6" name= "SCRMiddleRatio" description= "SCR Middle Ratio" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
<config default= "8" name= "SCRLowerRatio" description= "SCR Lower Ratio" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
<config default= "600" name= "RoutineTimeOut" description= "Routine超时时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "30" name= "MFC1to16RampTime" description= "Process Abort后MFC1到16Ramp到Default值的时间" max= "100" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "30" name= "MFC19to40RampTime" description= "Process Abort后MFC19到40Ramp到Default值的时间" max= "100" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "Pump" >
<config default= "1" name= "PumpBasePressure" description= "Pump Base Pressure" max= "1000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "300" name= "PumpTimeOut" description= "Pump To Base Pressure Timeout" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "600" name= "RoutineTimeOut" description= "Routine超时时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "Vent" >
<config default= "1000" name= "VentBasePressure" description= "Vent Base Pressure" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "300" name= "VentTimeout" description= "Vent到设定压力超时时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "600" name= "RoutineTimeOut" description= "Routine超时时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "VacIdle" visible= "false" >
<config default= "0" name= "PumpPressure" description= "PumpPressure" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "300" name= "RoutineTimeOut" description= "Routine超时时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "Purge" >
<config default= "50" name= "CyclePurgeCount" description= "循环次数" max= "1000" min= "1" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "0" name= "PumpBasePressure" description= "Pump压力值" max= "1000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "10" name= "PumpDelayTime" description= "Pump到达压力后保持时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "300" name= "PumpTimeout" description= "Pump超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "980" name= "VentBasePressure" description= "Vent压力值" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "3" name= "VentDelayTime" description= "Vent到达压力后保持时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "300" name= "VentTimeout" description= "Vent超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "3000" name= "RoutineTimeOut" description= "Routine超时时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "300" name= "WaitPressureTimeout" description= "等待压力超时时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "false" name= "NeedFinalValveOpen" description= "Final Valve是否需要打开" max= "" min= "" paramter= "" tag= "" unit= "" visible= "true" type= "Bool" />
</configs>
<configs name= "Clean" >
<config default= "20" name= "CycleCleanCount" description= "循环次数" max= "1000" min= "1" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "1" name= "PumpBasePressure" description= "Pump压力值" max= "1000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "10" name= "PumpDelayTime" description= "Pump到达压力后保持时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "300" name= "PumpTimeout" description= "Pump超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "980" name= "VentBasePressure" description= "Vent压力值" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "3" name= "VentDelayTime" description= "Vent到达压力后保持时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "300" name= "VentTimeout" description= "Vent超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "20" visible= "false" name= "CleanTime" description= "吹扫时间" max= "1000" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "3000" name= "RoutineTimeOut" description= "Routine超时时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "200" name= "FinalPressure" description= "最后保持的压力" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
</configs>
<configs name= "MoExchange" >
<config default= "50" name= "CycleCount" description= "循环次数" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "30" name= "PumpTime" description= "换源Pump保持时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "30" name= "VentTime" description= "换源Vent保持时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "3000" name= "RoutineTimeOut" description= "Routine超时时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "LeakCheck" >
<config default= "0" name= "CyclePurgeCount" description= "循环次数" max= "1000" min= "1" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "1" name= "PumpBasePressure" description= "Pump压力值" max= "1000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "10" name= "PumpDelayTime" description= "Pump到达压力后保持时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "300" name= "PumpTimeout" description= "Pump超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "980" name= "VentBasePressure" description= "Vent压力值" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "3" name= "VentDelayTime" description= "Vent到达压力后保持时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "300" name= "VentTimeout" description= "Vent超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "10" name= "ContinuePumpTime" description= "Pm压力达到0之后继续Pump时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "300" name= "LeakCheckDelayTime" description= "Leak Check Delay Time" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "0.5" name= "LeakSpec" description= "LeakSpec" max= "100" min= "0" paramter= "" tag= "" unit= "mbar/min" type= "Double" />
<config default= "3000" name= "RoutineTimeOut" description= "Routine超时时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
2026-04-01 09:46:54 +08:00
<configs name= "MFC" >
<config default= "1.5" name= "MinScale" description= "MFC Min Scale" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
<config default= "10" name= "WarningTime" description= "设置值和反馈值之差超限后,引发警告的延迟时间" max= "300" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "true" />
<config default= "5" name= "WarningRange" description= "(反馈值-设置值)/设置值 * 100% 超过该百分比后,引发警告" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" visible= "true" />
<config default= "10" name= "AlarmTime" description= "设置值和反馈值之差超限后,引发报警的延迟时间" max= "300" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "true" />
<config default= "10" name= "AlarmRange" description= "(反馈值-设置值)/设置值 * 100% 超过该百分比后,引发报警" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" visible= "true" />
<configs name= "Mfc1" >
2026-03-24 15:04:02 +08:00
<config default= "10000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
2026-04-01 09:46:54 +08:00
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
2026-03-24 15:04:02 +08:00
</configs>
2026-04-01 09:46:54 +08:00
<configs name= "Mfc2" >
2026-03-24 15:04:02 +08:00
<config default= "10000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
2026-04-01 09:46:54 +08:00
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
2026-03-24 15:04:02 +08:00
</configs>
2026-04-01 09:46:54 +08:00
<configs name= "Mfc3" >
<config default= "10000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc4" >
2026-03-24 15:04:02 +08:00
<config default= "1000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
2026-04-01 09:46:54 +08:00
<config default= "50" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "N2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc5" >
<config default= "500" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "25" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "500" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "N2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
<config default= "true" name= "IsInstalled" description= "MFC5是否安装" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
</configs>
<configs name= "Mfc6" >
<config default= "1000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "50" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
2026-03-24 15:04:02 +08:00
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
2026-04-01 09:46:54 +08:00
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
2026-03-24 15:04:02 +08:00
</configs>
2026-04-01 09:46:54 +08:00
<configs name= "Mfc7" >
<config default= "500" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "25" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "500" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc8" >
<config default= "1000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "50" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc9" >
<config default= "10000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc10" >
2026-03-24 15:04:02 +08:00
<config default= "5000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "250" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "5000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
2026-04-01 09:46:54 +08:00
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
2026-03-24 15:04:02 +08:00
</configs>
2026-04-01 09:46:54 +08:00
<configs name= "Mfc11" >
<config default= "1000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "50" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc12" >
<config default= "1000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "50" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc13" >
<config default= "5000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "250" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "5000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "HCL" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc14" >
<config default= "500" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "25" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "500" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "SiH4" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc15" >
<config default= "10000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc16" >
<config default= "500" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "25" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "500" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "C2H4" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc17" >
<config default= "10000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "25" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "500" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "C2H4" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
2026-06-04 09:07:09 +08:00
<configs name= "Mfc18" >
<config default= "10000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
2026-04-01 09:46:54 +08:00
<configs name= "Mfc19" >
<config default= "10000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc20" >
<config default= "5000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "250" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "5000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc22" >
<config default= "10000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc23" >
<config default= "5000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "250" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "5000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc25" >
<config default= "10000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc26" >
<config default= "5000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "250" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "5000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc27" >
<config default= "200000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "5000" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "30000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc28" >
<config default= "30000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "1500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "30000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc29" >
<config default= "15000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "750" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "15000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
2026-06-04 09:07:09 +08:00
<configs name= "Mfc30" >
<config default= "5000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "250" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "5000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
2026-04-01 09:46:54 +08:00
<configs name= "Mfc31" >
<config default= "20000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "1000" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "20000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc32" >
<config default= "20000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "1000" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "20000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc33" >
<config default= "5000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "250" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "5000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc35" >
<config default= "30000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "1500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "30000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc36" >
<config default= "30000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "30000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc37" >
<config default= "20000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "20000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc38" >
<config default= "20000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "20000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc40" >
<config default= "100000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "10000" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "200000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc41" >
<config default= "100000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "10000" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "200000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc42" >
<config default= "100000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "10000" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "200000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc43" >
<config default= "100000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "100000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc44" >
<config default= "100000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "100000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc45" >
<config default= "100000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "100000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
</configs>
2026-03-24 15:04:02 +08:00
<configs name= "PC" >
<config default= "10" name= "WarningTime" description= "设置值和反馈值之差超限后,引发警告的延迟时间" max= "300" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "true" />
<config default= "5" name= "WarningRange" description= "(反馈值-设置值)/设置值 * 100% 超过该百分比后,引发警告" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" visible= "true" />
<config default= "10" name= "AlarmTime" description= "设置值和反馈值之差超限后,引发报警的延迟时间" max= "300" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "true" />
<config default= "10" name= "AlarmRange" description= "(反馈值-设置值)/设置值 * 100% 超过该百分比后,引发报警" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" visible= "true" />
<configs name= "PC1" >
<config default= "5000" name= "Scale" description= "Scale" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "1500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "3000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "0" name= "Offset" description= "PC Offset" max= "1000" min= "-1000" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "true" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "PC2" >
<config default= "5000" name= "Scale" description= "Scale" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "1500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "3000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "0" name= "Offset" description= "PC Offset" max= "1000" min= "-1000" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "true" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "PC3" >
<config default= "5000" name= "Scale" description= "Scale" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "1900" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "3000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "0" name= "Offset" description= "PC Offset" max= "1000" min= "-1000" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "true" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "PC4" >
<config default= "10000" name= "Scale" description= "Scale" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "1200" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "3000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "0" name= "Offset" description= "PC Offset" max= "1000" min= "-1000" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "true" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "PC5" >
<config default= "10000" name= "Scale" description= "Scale" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "1260" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "3000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "0" name= "Offset" description= "PC Offset" max= "1000" min= "-1000" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "true" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "PC6" >
<config default= "10000" name= "Scale" description= "Scale" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "1260" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "3000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "0" name= "Offset" description= "PC Offset" max= "1000" min= "-1000" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "true" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "PC7" >
<config default= "10000" name= "Scale" description= "Scale" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "1260" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "3000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "0" name= "Offset" description= "PC Offset" max= "1000" min= "-1000" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "true" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "PC8" >
<config default= "10000" name= "Scale" description= "Scale" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "1260" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "3000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "0" name= "Offset" description= "PC Offset" max= "1000" min= "-1000" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "true" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "PC9" >
<config default= "30000" name= "Scale" description= "Scale" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "150" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "3000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "0" name= "Offset" description= "PC Offset" max= "1000" min= "-1000" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "true" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
</configs>
<configs name= "ConfinementRing" >
<config default= "0" name= "UpPos" description= "隔热罩上位置坐标" max= "100" min= "-100" paramter= "" tag= "" unit= "mm" type= "Double" />
<config default= "0" name= "DownPos" description= "隔热罩下位置坐标" max= "100" min= "-100" paramter= "" tag= "" unit= "mm" type= "Double" />
<config default= "180" name= "MoveSpeed" description= "隔热罩移动速度" max= "500" min= "0" paramter= "" tag= "" unit= "mm/min" type= "Double" />
</configs>
<configs name= "DryRun" visible= "false" >
<config default= "false" name= "IsDryRun" description= "是否空跑工艺" max= "" min= "" paramter= "" tag= "" unit= "" visible= "true" type= "Bool" />
<config default= "10" name= "DryRunDelayTime" description= "空跑工艺,保持多长时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "PreProcess" >
<config default= "200" name= "ChamberPressure" description= "反应腔的目标压力" max= "1050" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "10" name= "RampDelayTime" description= "Ramp到目标值所需时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "850" name= "ProcessBeginTempCondition" description= "等待温度到达此数值后开始工艺" max= "1700" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "5" name= "ServoBeforeUpDelay" description= "隔热罩升起前延迟时间" max= "60" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "Process" >
<config default= "-50" name= "TempOffset" description= "温度的偏移量,用于过冲" max= "100" min= "-100" paramter= "" tag= "" unit= "℃" type= "Double" />
</configs>
<configs name= "ChamberDoor" visible= "false" >
<config default= "10" name= "MoveTimeout" description= "开关闸板阀超时时间" max= "100" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "MainPump" visible= "false" >
<config default= "10" name= "StartTimeout" description= "Start Timeout" max= "100" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "10" name= "ResetErrorTimeout" description= "Reset Error Timeout" max= "100" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "Efficiency" >
<config default= "1" name= "TCS-Eff" description= "TCS Bubbling efficiency for recipe" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "TMA-Eff" description= "TMA Bubbling efficiency for recipe" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "TMAFlowRatio" description= "TMA流量计算需要乘以的系数" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "TCSFlowRatio" description= "TCS流量计算需要乘以的系数" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "HCLFlowRatio" description= "HCL流量计算需要乘以的系数" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "C2H4/C3H8FlowRatio" description= "C2H4/C3H8流量计算需要乘以的系数" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "SiH4FlowRatio" description= "SiH4流量计算需要乘以的系数" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "PN2FlowRatio" description= "PN2流量计算需要乘以的系数" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "ArFlowRatio" description= "Ar流量计算需要乘以的系数" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "H2FlowRatio" description= "H2流量计算需要乘以的系数" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
</configs>
<configs name= "CoolingWater" >
<config default= "5" name= "WarningOffset" description= "超温警告偏移,当水温超过(报警值-Offset)时,产生警告" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" visible= "false" />
<config default= "5" name= "WarningDelay" description= "设置值和反馈值之差超限后,引发警告的延迟时间" max= "300" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "5" name= "AlarmDelay" description= "设置值和反馈值之差超限后,引发报警的延迟时间" max= "300" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "3" name= "FilterDuration" description= "温度采样值滤波时间,对指定时长内的采样数据求算术平均值作为报警判断" max= "10" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "45" name= "SHFlowTemp" description= "U1 DO196 喷淋头超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "ChamTopFlowTemp" description= "U2 DO197 PM中间法兰超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "ChamMiddleFlow1Temp" description= "U3 DO198 PM腔中部1超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "ChamMiddleFlow2Temp" description= "U4 DO195 PM腔中部2超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "ChamBottomFlowTemp" description= "U5 DO199 PM腔下部超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "SpareFlowTemp" description= "U6 DO200 PM腔底部超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "PowerRod1FlowTemp" description= "U7 DO201 下电极超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "PowerRod2FlowTemp" description= "U8 DO202 下电极和磁流体超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "ForelineFlowTemp" description= "U9 DO203 真空管道和方口法兰超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "ElectrodeWFlowTemp" description= "U10 DO204 侧壁电极超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "TMPump1FlowTemp" description= "U11 DO205 TM干泵超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "Spare1FlowTemp" description= "U12 DO207 备用1超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "Spare2FlowTemp" description= "U13 DO208 备用2超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "TransformerFlowTemp" description= "U14 DO206 变压器超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
</configs>
<configs name= "IdleService" visible= "false" >
<config default= "false" name= "IdleFirstEnable" description= "IdleService是否启用首次Clean" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "IdlePurgeEnable" description= "IdleService是否启用Purge Clean" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "CountCleanEnable" description= "是否启用每运行多少炉需要执行Recipe" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "" name= "IdleFirstRecipe" description= "IdleService首次运行Recipe的文件名称" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "" name= "IdlePurgeRecipe" description= "IdleService后续运行Recipe的文件名称" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "" name= "CountCleanRecipe" description= "每运行多少炉需要执行Recipe的文件名称" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "60" name= "IdleFirstTime" description= "第一次待机多长时间调用Recipe" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "true" />
<config default= "60" name= "IdlePurgeTime" description= "后续每隔多长时间调用Recipe" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "true" />
<config default= "5" name= "CleanRunCount" description= "每运行多少炉需要执行Clean Recipe" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "true" />
<config default= "0" name= "CurrentRunCount" description= "当前炉计数" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
</configs>
<configs name= "PT" >
<config default= "0" name= "PT1_Offset" description= "PT1 Offset值" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "PT1_K" description= "PT1 K值" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "PT2_Offset" description= "PT2 Offset值" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "PT2_K" description= "PT2 K值" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "PT3_Offset" description= "PT3 Offset值" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "PT3_K" description= "PT3 K值" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "PT4_Offset" description= "PT4 Offset值" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "PT4_K" description= "PT4 K值" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "PT9_Offset" description= "PT9 Offset值" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "PT9_K" description= "PT9 K值" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "PT10_Offset" description= "PT10 Offset值" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "PT10_K" description= "PT10 K值" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
</configs>
<configs name= "WaterTemp" >
<config default= "0" name= "U1_Water" description= "SHFlow" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U2_Water" description= "ChamTopFlow" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U3_Water" description= "ChamMiddleFlow1" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U4_Water" description= "ChamMiddleFlow2" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U5_Water" description= "ChamBottomFlow" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U6_Water" description= "Foreline1.Flow" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U7_Water" description= "PowerRod1Flow" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U8_Water" description= "PowerRod2Flow" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U9_Water" description= "Foreline2.Flow" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U10_Water" description= "Electrode-W.Flow" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U11_Water" description= "TMPump1Flow" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U12_Water" description= "Spare1" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U13_Water" description= "Spare2" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U14_Water" description= "TransformerFlow" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
</configs>
<configs name= "RotationAlarm" >
<config default= "true" name= "WarningOrAlarm" description= "True:Alarm, False:Warning" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "3" name= "Threshold" description= "Threshold of rotation speed." max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "3" name= "Times" description= "Out of gauge times, calculate one time per second." max= "100" min= "1" paramter= "" tag= "" unit= "" type= "Integer" />
</configs>
<configs name= "LineHeaterTemp" >
<config default= "0" name= "加热带温区1" description= "HeatTMAHigh 温度上限,设为0忽略报警" max= "100" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "70" name= "加热带温区2" description= "HeatTCSPanel 温度上限,设为0忽略报警" max= "100" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "70" name= "加热带温区3" description= "HeatinsidePanel 温度上限,设为0忽略报警" max= "100" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "70" name= "加热带温区4" description= "HeatoutsidePane 温度上限,设为0忽略报警" max= "100" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "70" name= "加热带温区5" description= "HeatoutsideSH 温度上限,设为0忽略报警" max= "100" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "70" name= "加热带温区6" description= "HeatLeakBypass 温度上限,设为0忽略报警" max= "100" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "0" name= "PumpLineTempLimt" description= "PumpLineTempLimt 温度上限,设为0忽略报警" max= "200" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "Warning" name= "PumpLineTempAlarm" description= "报警等级(加热带温区1-6固定为Warning)" max= "" min= "" paramter= "Warning;Alarm" tag= "ReadOnlySelection" unit= "" type= "String" visible= "true" />
</configs>
<configs name= "TempSensor" >
<config default= "AKunTemp.t1" name= "MiddleTemp" description= "设置Middle温度数据通道,重启生效" max= "" min= "" paramter= "AETemp.t1;AETemp.t2;AETemp.t3;AETemp.t4;AKunTemp.t1;AKunTemp.t2;AKunTemp.t3;AKunTemp.t4;SensorTemp1.t1;SensorTemp2.t1;SensorTemp3.t1;SensorTemp4.t1;StrongTemp1.t1;StrongTemp2.t1;StrongTemp3.t1;StrongTemp4.t1;Disabled" tag= "ReadOnlySelection" unit= "" type= "String" visible= "false" />
<config default= "AKunTemp.t2" name= "OuterTemp" description= "设置Outer温度数据通道,重启生效" max= "" min= "" paramter= "AETemp.t1;AETemp.t2;AETemp.t3;AETemp.t4;AKunTemp.t1;AKunTemp.t2;AKunTemp.t3;AKunTemp.t4;SensorTemp1.t1;SensorTemp2.t1;SensorTemp3.t1;SensorTemp4.t1;StrongTemp1.t1;StrongTemp2.t1;StrongTemp3.t1;StrongTemp4.t1;Disabled" tag= "ReadOnlySelection" unit= "" type= "String" visible= "false" />
<config default= "Disabled" name= "InnerTemp" description= "设置Inner温度数据通道,重启生效" max= "" min= "" paramter= "AETemp.t1;AETemp.t2;AETemp.t3;AETemp.t4;AKunTemp.t1;AKunTemp.t2;AKunTemp.t3;AKunTemp.t4;SensorTemp1.t1;SensorTemp2.t1;SensorTemp3.t1;SensorTemp4.t1;StrongTemp1.t1;StrongTemp2.t1;StrongTemp3.t1;StrongTemp4.t1;Disabled" tag= "ReadOnlySelection" unit= "" type= "String" visible= "false" />
<config default= "AKunTemp.CH1" name= "Middle" description= "设置Middle温度数据通道,重启生效" max= "" min= "" paramter= "AETemp.CH1;AETemp.CH2;AETemp.CH3;AETemp.CH4;AKunTemp.CH1;AKunTemp.CH2;AKunTemp.CH3;AKunTemp.CH4;SensorTemp1.CH1;SensorTemp2.CH1;SensorTemp3.CH1;SensorTemp4.CH1;StrongTemp1.CH1;StrongTemp2.CH1;StrongTemp3.CH1;StrongTemp4.CH1;Disabled" tag= "ReadOnlySelection" unit= "" type= "String" />
<config default= "AKunTemp.CH2" name= "Outer" description= "设置Outer温度数据通道,重启生效" max= "" min= "" paramter= "AETemp.CH1;AETemp.CH2;AETemp.CH3;AETemp.CH4;AKunTemp.CH1;AKunTemp.CH2;AKunTemp.CH3;AKunTemp.CH4;SensorTemp1.CH1;SensorTemp2.CH1;SensorTemp3.CH1;SensorTemp4.CH1;StrongTemp1.CH1;StrongTemp2.CH1;StrongTemp3.CH1;StrongTemp4.CH1;Disabled" tag= "ReadOnlySelection" unit= "" type= "String" />
<config default= "Disabled" name= "Inner" description= "设置Inner温度数据通道,重启生效" max= "" min= "" paramter= "AETemp.CH1;AETemp.CH2;AETemp.CH3;AETemp.CH4;AKunTemp.CH1;AKunTemp.CH2;AKunTemp.CH3;AKunTemp.CH4;SensorTemp1.CH1;SensorTemp2.CH1;SensorTemp3.CH1;SensorTemp4.CH1;StrongTemp1.CH1;StrongTemp2.CH1;StrongTemp3.CH1;StrongTemp4.CH1;Disabled" tag= "ReadOnlySelection" unit= "" type= "String" />
<config default= "None" name= "FilterType" description= "温度滤波器类型" max= "0" min= "0" paramter= "None;MAF" tag= "ReadOnlySelection" unit= "" type= "String" />
<configs name= "Filters" >
<configs name= "MAF" >
<config default= "1000" name= "WindowSize" description= "移动平均滤波器滤波窗口" max= "120000" min= "0" paramter= "" tag= "" unit= "ms" type= "Integer" />
</configs>
<configs name= "FIR" >
<config default= "128" name= "Order" description= "FIR滤波器阶数" max= "10240" min= "0" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "1;1;1;1;1;1;" name= "Coefficients" description= "FIR滤波器系数;系数个数需和阶数匹配,每个系数之间使用;分隔" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
</configs>
<configs name= "Kalman" >
<config default= "1;1;1;1;1;1;" name= "Coefficients" description= "卡尔曼滤波器系数;每个系数之间使用;分隔" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
</configs>
</configs>
</configs>
</configs>
<configs name= "PM2" >
<config default= "PM2" name= "DisplayName" description= "PM自定义名称" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "#00FFFFFF" name= "BackgroundColor" description= "PM页面自定义背景色" max= "" min= "" paramter= "" tag= "" unit= "" type= "Color" />
2026-03-24 17:33:10 +08:00
<config default= "PN2" name= "OperationView" description= "PM气路图界面" max= "" min= "" paramter= "PN2" tag= "ReadOnlySelection" unit= "" type= "String" />
2026-03-24 15:04:02 +08:00
<config default= "false" name= "BypassInterlock" description= "Bypass Interlock" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "BypassEnableTable" description= "Bypass EnableTable" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "Sic" visible= "false" name= "RecipeChamberType" description= "Recipe Chamber Type" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "" name= "LastRecipeName" description= "last recipe name" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "127.0.0.1:102" name= "SiemensIP" description= "Siemens IP Address,Default IP:192.168.1.205:102" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "S1500" visible= "false" name= "SiemensType" description= "Siemens Type" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "30" name= "PT1PT2PressureDifferenceUpperLimit" description= "PT1和PT2最大压差上限" max= "1100" min= "0" paramter= "" tag= "" unit= "s" type= "Double" />
<config default= "Warning" name= "PT1PT2PressureDifferenceMaxAlarmLevel" description= "工艺过程中PT1和PT2最大压差超限时产生报警的等级" max= "" min= "" paramter= "Alarm;Warning" tag= "ReadOnlySelection" unit= "" type= "String" />
<config default= "5" name= "ThrottlePressureMaxDiff" description= "蝶阀调节值与实际压力的差值小于此数值则表示到位" max= "1000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "120" name= "ThrottlePressureTimeout" description= "蝶阀调节值超时时间" max= "2000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "5" name= "ThrottlePressureRate" description= "蝶阀每秒调节速率(mbar/每秒)" max= "1000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "5" name= "ThrottlePositionRate" description= "蝶阀每秒调节速率(百分比/每秒)" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
<config default= "300" visible= "false" name= "RotationCloseTimeout" description= "关闭旋转超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "0" name= "ThrottlePositionDefaultValue" description= "蝶阀位置模式默认值" max= "100" min= "0" paramter= "" tag= "" unit= "s" type= "Double" />
<config default= "1100" name= "ThrottlePressureDefaultValue" description= "蝶阀压力模式默认值" max= "1500" min= "0" paramter= "" tag= "" unit= "s" type= "Double" />
<config default= "400" name= "ThrottlePositionModeMaxPressure" description= "蝶阀允许位置模式需要的最大压力值" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "1000*10,3000*10,3000*10,4000*10,6000*10,8000*10,10000*10,12000*10,14000*10,2500*10" name= "MFC28DynamicFlow" description= "MFC28 动态流量" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "500*10,2000*10,2500*10,3500*10,5500*10,7500*10,9500*10,11500*10,13000*10,2000*10" name= "MFC29DynamicFlow" description= "MFC29 动态流量" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "1000*10,3000*10,5000*10,6000*10,8000*10,10000*10,12000*10,14000*10,16000*10,4000*10" name= "MFC31DynamicFlow" description= "MFC31 动态流量" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "4000*10,7000*10,11000*10,13000*10,16000*10,19000*10,23000*10,28000*10,34000*10,11000*10" name= "MFC40DynamicFlow" description= "MFC40 动态流量" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "false" name= "PreTransferPSUEnable" description= "传盘是否开启PSU加热" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "true" name= "PreTransferSCREnable" description= "传盘是否开启SCR加热" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "ReactorSuspectorCheckEnable" description= "传盘后是否检查ReactorSuspectorCheck Sensor" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "50" name= "ReactorPressRisingRateLimit" description= "腔体压力上升速率超速报警" max= "1000" min= "0" paramter= "" tag= "" unit= "mbar/s" type= "Double" />
<config default= "1020" name= "PressureForV27ForceOpen" description= "Pressure For V27 Switch" max= "1150" min= "850" paramter= "" tag= "" unit= "mbar" type= "Double" visible= "false" />
<config default= "960" name= "PressureForV27ForceClose" description= "Pressure For V27 Switch" max= "1150" min= "850" paramter= "" tag= "" unit= "mbar" type= "Double" visible= "false" />
<config default= "20" name= "TCSFluidInfusionTime" description= "TCS补液时间" max= "600" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "false" name= "TCSFluidInfusionFeedbackDI" description= "TCS补液使用DI反馈信号控制" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "Sic\Routine\ATMIdle" name= "AtmIdleFileName" description= "ATM Idle Routine文件路径" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "Sic\Routine\VACIdle" name= "VacIdleFileName" description= "VAC Idle Routine文件路径" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "Sic\Routine\ProcessIdle" name= "ProcessIdleFileName" description= "Process Idle Routine文件路径" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "Sic\Routine\Pump" name= "PumpFileName" description= "Pump Routine文件路径" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "Sic\Routine\Vent" name= "VentFileName" description= "Vent Routine文件路径" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "Sic\\Routine\Purge" name= "PurgeFileName" description= "Purge Routine文件路径" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "Sic\\Routine\Clean" name= "CleanFileName" description= "Clean Routine文件路径" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "Sic\Routine\ExchangeMOTCS" name= "ExchangeMOTCSFileName" description= "ExchangeTCS Routine文件路径" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "Sic\Routine\ExchangeMOTMA" name= "ExchangeMOTMAFileName" description= "ExchangeTMA Routine文件路径" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "Sic\Routine\Isolation" name= "IsolationFileName" description= "Isolation Routine文件路径" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "Sic\Routine\LeakCheck" name= "LeakCheckFileName" description= "LeakCheck Routine文件路径" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "Sic\Routine\Abort" name= "AbortFileName" description= "Abort Routine文件路径" max= "" min= "" paramter= "" tag= "" visible= "false" unit= "" type= "String" />
<config default= "" name= "OpenLidCountDownTime" visible= "false" description= "临时保存开腔倒计时开始时间" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "TMAEnable" description= "TMA是否选装" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "C2H4" name= "CarbonSource" description= "碳源类型,C2H4、C3H8" max= "" min= "" paramter= "C2H4;C3H8" tag= "ReadOnlySelection" unit= "" type= "String" />
<config default= "true" name= "ShutDownPLC" description= "选择否关软件后很快就关闭加热,PLC走宕机流程" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<configs name= "Heater" >
<config default= "false" name= "PSUOuterAutoEnable" description= "PSU Outer是否为Auto控制" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "false" />
<config default= "10" name= "TempRampRate" description= "TC温度每秒调节速率(℃/每秒)" max= "100" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "0.1" name= "AmpereRampRate" description= "TC1功率每秒调节速率(%/每秒)" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
<config default= "0.1" name= "KWRampRate" description= "TC2功率每秒调节速率(%/每秒)" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
<config default= "20" name= "PyroWarmEffectFromTime" description= "Pyro温度报警在进入Process状态下多久才有效" max= "1800" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "20" name= "PyroWarmEffectEndTime" description= "Pyro温度报警在结束Process状态前多久才有效" max= "1800" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "50" name= "PyroWarmMaxDiff" description= "Pyro的MidlleTemp,OuterTemp任意两个温度差大于此数值需要报警" max= "1000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "600" name= "PyroWarmBaseTemp" visible= "false" description= "Pyro温度报警需要满足BaseTemp" max= "2000" min= "200" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "true" name= "PyroWarmIsAlarm" visible= "false" description= "Pyro温度差过大报警类型为Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "1700" name= "PSUTempHighLimit" description= "PSU Temp High Limit(℃)" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "600" name= "PSUTempLowLimit" description= "PSU Temp Low Limit(℃)" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "1700" name= "SCRTempHighLimit" visible= "false" description= "SCR Temp High Limit(℃)" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "900" name= "SCRTempLowLimit" visible= "false" description= "SCR Temp Low Limit(℃)" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "70" name= "LineHeaterTempHighLimit" description= "气柜加热带温度上限;设为0表示忽略报警" max= "100" min= "0" paramter= "" tag= "" unit= "℃" visible= "true" type= "Double" />
<config default= "0.5" name= "PSU1ResistanceMax" description= "Max PSU Inner Resistance Max Limit" max= "1000" min= "0" paramter= "" tag= "" unit= "Ω" type= "Double" />
<config default= "0.5" name= "PSU2ResistanceMax" description= "Max PSU Middle Resistance Max Limit" max= "1000" min= "0" paramter= "" tag= "" unit= "Ω" type= "Double" />
<config default= "0.5" name= "PSU3ResistanceMax" description= "Max PSU Outer Resistance Max Limit" max= "1000" min= "0" paramter= "" tag= "" unit= "Ω" type= "Double" />
<config default= "0.5" name= "SCR1ResistanceMax" description= "Max SCR Upper Resistance Max Limit" max= "1000" min= "0" paramter= "" tag= "" unit= "Ω" type= "Double" />
<config default= "0.5" name= "SCR2ResistanceMax" description= "Max SCR Middle Resistance Max Limit" max= "1000" min= "0" paramter= "" tag= "" unit= "Ω" type= "Double" />
<config default= "0.5" name= "SCR3ResistanceMax" description= "Max SCR Lower Resistance Max Limit" max= "1000" min= "0" paramter= "" tag= "" unit= "Ω" type= "Double" />
<config default= "5" name= "ResistanceMonitorHysteresis" description= "电阻检测迟滞时间,当电阻持续超限指定时间后,再产生报警" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "Warning" name= "InProcessResistanceFailAlarmLevel" description= "工艺过程中检测到电阻超限时产生报警的等级" max= "" min= "" paramter= "Alarm;Warning" tag= "ReadOnlySelection" unit= "" type= "String" />
<config default= "5" name= "InProcessResistanceMonitorIgnoreDuration" description= "工艺启动后和结束前的指定时间内忽略电阻超限检查" max= "100" min= "0" paramter= "" tag= "" unit= "s" type= "Double" visible= "false" />
<config default= "0" name= "PIDLimitLower" description= "Pyro模式PID整定限幅下限" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "100" name= "PIDLimitUpper" description= "Pyro模式PID整定限幅上限" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "4" name= "PIDRateLimit" description= "Pyro模式PID整定输出幅度变化速率" max= "100" min= "1" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "false" name= "AETempRasingFastIsAlarm" description= "AETemp温度上升过快报警类型为Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "100" visible= "false" name= "SCRTempRasingRate" description= "SCRTemp每秒的上升速率,超过此范围报警" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "20" name= "AETempMiddleRasingRate" description= "AETemp Middle每秒的上升速率,超过此范围报警" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "20" name= "AETempOuterRasingRate" description= "AETemp Outer每秒的上升速率,超过此范围报警" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<!--<config default="5" name="AETempFrequency" description="AETemp 采样频率" max="300" min="0" paramter="" tag="" unit="s" type="Double" />-->
<config default= "850" name= "PlacePVTempLimit" description= "往PM放盘时,需要等待温度低于此数值" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "900" name= "PickPVTempLimit" description= "从PM取盘时,需要等待温度低于此数值" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "1.0" name= "PSU1Y" description= "底部恒功率模式控制方案PSU1百分比" max= "99999" min= "0" paramter= "" tag= "" unit= "" visible= "false" type= "Double" />
<config default= "1.0" name= "PSU2Y" description= "底部恒功率模式控制方案PSU2百分比" max= "99999" min= "0" paramter= "" tag= "" unit= "" visible= "false" type= "Double" />
<config default= "1.0" name= "PSU3Y" description= "底部恒功率模式控制方案PSU3百分比" max= "99999" min= "0" paramter= "" tag= "" unit= "" visible= "false" type= "Double" />
<config default= "0.5" name= "PSU1Power" description= "底部恒功率模式控制方案PSU1功率" max= "99999" min= "0" paramter= "" tag= "" unit= "" visible= "false" type= "Double" />
<config default= "6.0" name= "PSU2Power" description= "底部恒功率模式控制方案PSU2功率" max= "99999" min= "0" paramter= "" tag= "" unit= "" visible= "false" type= "Double" />
<config default= "6.0" name= "PSU3Power" description= "底部恒功率模式控制方案PSU3功率" max= "99999" min= "0" paramter= "" tag= "" unit= "" visible= "false" type= "Double" />
<config default= "25" name= "PyroDiffWarning" description= "Pyro控温时,温差超过此值时警告" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "50" name= "PyroDiffAlarm" description= "Pyro控温时,温差超过此值时报警" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "120" name= "PyroDiffCheckDelay" description= "进入Pyro控温后,延迟当前设置时间后开始监测温差" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Double" visible= "false" />
<config default= "3000" name= "PyroDiffFilterTime" description= "Pyro控温时,温差警告或报警的滤波时间" max= "10000" min= "0" paramter= "" tag= "" unit= "ms" type= "Double" />
<!--
<config default="false" name="PSU2OutputLimitHighTuningByRecipe" description="PSU2输出限幅上限值由Recipe调节" max="" min="" paramter="" tag="" unit="" type="Bool" visible="false" />
<config default="1600" name="PSU2OutputLimitHighTuningTemp" description="PSU2输出限幅限值生效温度" max="2500" min="0" paramter="" tag="" unit="" visible="false" type="Double" />
<config default="100" name="PSU2OutputLimitHigh" description="PSU2输出限幅上限值" max="100" min="0" paramter="" tag="" unit="" visible="false" type="Double" />
<config default="0" name="PSU2OutputLimitLow" description="PSU2输出限幅下限值" max="100" min="0" paramter="" tag="" unit="" visible="false" type="Double" />
-->
</configs>
<configs name= "PowerDetection" >
<configs name= "PSU1Power" >
<config default= "25" name= "MaxPower" description= "最大功率KW" max= "1000" min= "0" paramter= "" tag= "" unit= "KW" type= "Double" />
<config default= "99" name= "MaxHighPowerPercent" description= "最大功率输出,连续2秒超过设定值报警,设0为禁用," max= "1000" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
</configs>
<configs name= "PSU2Power" >
<config default= "25" name= "MaxPower" description= "最大功率KW" max= "1000" min= "0" paramter= "" tag= "" unit= "KW" type= "Double" />
<config default= "99" name= "MaxHighPowerPercent" description= "最大功率输出,连续2秒超过设定值报警,设0为禁用" max= "1000" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
</configs>
<configs name= "PSU3Power" >
<config default= "25" name= "MaxPower" description= "最大功率KW" max= "1000" min= "0" paramter= "" tag= "" unit= "KW" type= "Double" />
<config default= "99" name= "MaxHighPowerPercent" description= "最大功率输出,连续2秒超过设定值报警,设0为禁用" max= "1000" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
</configs>
<configs name= "SCR1Power" >
<config default= "25" name= "MaxPower" description= "最大功率KW" max= "1000" min= "0" paramter= "" tag= "" unit= "KW" type= "Double" />
<config default= "99" name= "MaxHighPowerPercent" description= "最大功率输出,连续2秒超过设定值报警,设0为禁用," max= "1000" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
</configs>
<configs name= "SCR2Power" >
<config default= "25" name= "MaxPower" description= "最大功率KW" max= "1000" min= "0" paramter= "" tag= "" unit= "KW" type= "Double" />
<config default= "99" name= "MaxHighPowerPercent" description= "最大功率输出,连续2秒超过设定值报警,设0为禁用" max= "1000" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
</configs>
<configs name= "SCR3Power" >
<config default= "25" name= "MaxPower" description= "最大功率KW" max= "1000" min= "0" paramter= "" tag= "" unit= "KW" type= "Double" />
<config default= "99" name= "MaxHighPowerPercent" description= "最大功率输出,连续2秒超过设定值报警,设0为禁用" max= "1000" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
</configs>
</configs>
<configs name= "ITAUPSA" >
<config default= "false" name= "EnableDevice" description= "PM2 UPSA install" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "192.168.2.106" name= "Address" description= "PM2 UPSA address 192.168.2.106" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "1" name= "DeviceAddress" description= "PM2 UPSA device address" max= "1000" min= "0" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "false" name= "EnableLogMessage" description= "PM2 UPSA log message" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
</configs>
<configs name= "ITAUPSB" >
<config default= "false" name= "EnableDevice" description= "PM2 UPSB install" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "192.168.2.116" name= "Address" description= "PM2 UPSB address 192.168.2.116" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "1" name= "DeviceAddress" description= "PM2 UPSB device address" max= "1000" min= "0" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "false" name= "EnableLogMessage" description= "PM2 UPSB log message" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
</configs>
<configs name= "EATONUPS" >
<config default= "false" name= "EnableDevice" description= "PM2 EATONUPS install" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "192.168.1.206" name= "Address" description= "PM2 EATONUPS address 192.168.1.206" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "1" name= "DeviceAddress" description= "PM2 EATONUPS device address" max= "1000" min= "0" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "false" name= "EnableLogMessage" description= "PM2 EATONUPS log message" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
</configs>
<configs name= "ProcessIdle" >
<config default= "10" name= "RotationSpeed" description= "电机设置转速" max= "1000" min= "0" paramter= "" tag= "" unit= "rpm" type= "Integer" />
<config default= "200" name= "FinalPressure" description= "最后保持的压力" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "10" name= "PressureBalanceTime" description= "压力平衡时间" max= "100" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "true" name= "PSUHeaterEnable" description= "PSU加热是否启用" max= "" min= "" paramter= "" tag= "" unit= "" visible= "true" type= "Bool" />
<config default= "0" name= "PSUHeaterMode" description= "PSU HeatMode:0为Power,1为Pyro" max= "1" min= "0" paramter= "" tag= "" unit= "" type= "Integer" visible= "false" />
<config default= "5" name= "PSUInnerRatio" description= "PSU Inner Ratio" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
<config default= "16" name= "PSUMiddleRatio" description= "PSU Middle Ratio" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
<config default= "25" name= "PSUOuterRatio" description= "PSU Outer Ratio" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
<config default= "true" name= "SCRHeaterEnable" description= "SCR加热是否启用" max= "" min= "" paramter= "" tag= "" unit= "" visible= "true" type= "Bool" />
<config default= "0" name= "SCRHeaterMode" description= "SCR HeatMode:0为Power,1为Pyro" max= "1" min= "0" paramter= "" tag= "" unit= "" type= "Integer" visible= "false" />
<config default= "12" name= "SCRUpperRatio" description= "SCR Upper Ratio" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
<config default= "6" name= "SCRMiddleRatio" description= "SCR Middle Ratio" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
<config default= "8" name= "SCRLowerRatio" description= "SCR Lower Ratio" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
<config default= "600" name= "RoutineTimeOut" description= "Routine超时时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "30" name= "MFC1to16RampTime" description= "Process Abort后MFC1到16Ramp到Default值的时间" max= "100" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "30" name= "MFC19to40RampTime" description= "Process Abort后MFC19到40Ramp到Default值的时间" max= "100" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "Pump" >
<config default= "1" name= "PumpBasePressure" description= "Pump Base Pressure" max= "1000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "300" name= "PumpTimeOut" description= "Pump To Base Pressure Timeout" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "600" name= "RoutineTimeOut" description= "Routine超时时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "Vent" >
<config default= "1000" name= "VentBasePressure" description= "Vent Base Pressure" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "300" name= "VentTimeout" description= "Vent到设定压力超时时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "600" name= "RoutineTimeOut" description= "Routine超时时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "VacIdle" visible= "false" >
<config default= "0" name= "PumpPressure" description= "PumpPressure" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "300" name= "RoutineTimeOut" description= "Routine超时时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "Purge" >
<config default= "50" name= "CyclePurgeCount" description= "循环次数" max= "1000" min= "1" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "0" name= "PumpBasePressure" description= "Pump压力值" max= "1000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "10" name= "PumpDelayTime" description= "Pump到达压力后保持时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "300" name= "PumpTimeout" description= "Pump超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "980" name= "VentBasePressure" description= "Vent压力值" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "3" name= "VentDelayTime" description= "Vent到达压力后保持时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "300" name= "VentTimeout" description= "Vent超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "3000" name= "RoutineTimeOut" description= "Routine超时时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "300" name= "WaitPressureTimeout" description= "等待压力超时时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "false" name= "NeedFinalValveOpen" description= "Final Valve是否需要打开" max= "" min= "" paramter= "" tag= "" unit= "" visible= "true" type= "Bool" />
</configs>
<configs name= "Clean" >
<config default= "20" name= "CycleCleanCount" description= "循环次数" max= "1000" min= "1" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "1" name= "PumpBasePressure" description= "Pump压力值" max= "1000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "10" name= "PumpDelayTime" description= "Pump到达压力后保持时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "300" name= "PumpTimeout" description= "Pump超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "980" name= "VentBasePressure" description= "Vent压力值" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "3" name= "VentDelayTime" description= "Vent到达压力后保持时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "300" name= "VentTimeout" description= "Vent超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "20" visible= "false" name= "CleanTime" description= "吹扫时间" max= "1000" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "3000" name= "RoutineTimeOut" description= "Routine超时时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "200" name= "FinalPressure" description= "最后保持的压力" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
</configs>
<configs name= "MoExchange" >
<config default= "50" name= "CycleCount" description= "循环次数" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "30" name= "PumpTime" description= "换源Pump保持时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "30" name= "VentTime" description= "换源Vent保持时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "3000" name= "RoutineTimeOut" description= "Routine超时时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "LeakCheck" >
<config default= "0" name= "CyclePurgeCount" description= "循环次数" max= "1000" min= "1" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "1" name= "PumpBasePressure" description= "Pump压力值" max= "1000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "10" name= "PumpDelayTime" description= "Pump到达压力后保持时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "300" name= "PumpTimeout" description= "Pump超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "980" name= "VentBasePressure" description= "Vent压力值" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "3" name= "VentDelayTime" description= "Vent到达压力后保持时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "300" name= "VentTimeout" description= "Vent超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "10" name= "ContinuePumpTime" description= "Pm压力达到0之后继续Pump时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "300" name= "LeakCheckDelayTime" description= "Leak Check Delay Time" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "0.5" name= "LeakSpec" description= "LeakSpec" max= "100" min= "0" paramter= "" tag= "" unit= "mbar/min" type= "Double" />
<config default= "3000" name= "RoutineTimeOut" description= "Routine超时时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
2026-04-01 09:46:54 +08:00
<configs name= "MFC" >
<config default= "1.5" name= "MinScale" description= "MFC Min Scale" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
<config default= "10" name= "WarningTime" description= "设置值和反馈值之差超限后,引发警告的延迟时间" max= "300" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "true" />
<config default= "5" name= "WarningRange" description= "(反馈值-设置值)/设置值 * 100% 超过该百分比后,引发警告" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" visible= "true" />
<config default= "10" name= "AlarmTime" description= "设置值和反馈值之差超限后,引发报警的延迟时间" max= "300" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "true" />
<config default= "10" name= "AlarmRange" description= "(反馈值-设置值)/设置值 * 100% 超过该百分比后,引发报警" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" visible= "true" />
<configs name= "Mfc1" >
2026-03-24 15:04:02 +08:00
<config default= "10000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
2026-04-01 09:46:54 +08:00
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
2026-03-24 15:04:02 +08:00
</configs>
2026-04-01 09:46:54 +08:00
<configs name= "Mfc2" >
2026-03-24 15:04:02 +08:00
<config default= "10000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
2026-04-01 09:46:54 +08:00
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
2026-03-24 15:04:02 +08:00
</configs>
2026-04-01 09:46:54 +08:00
<configs name= "Mfc3" >
<config default= "10000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc4" >
2026-03-24 15:04:02 +08:00
<config default= "1000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
2026-04-01 09:46:54 +08:00
<config default= "50" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "N2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc5" >
<config default= "500" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "25" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "500" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "N2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
<config default= "true" name= "IsInstalled" description= "MFC5是否安装" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
</configs>
<configs name= "Mfc6" >
<config default= "1000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "50" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
2026-03-24 15:04:02 +08:00
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
2026-04-01 09:46:54 +08:00
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
2026-03-24 15:04:02 +08:00
</configs>
2026-04-01 09:46:54 +08:00
<configs name= "Mfc7" >
<config default= "500" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "25" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "500" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc8" >
<config default= "1000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "50" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc9" >
<config default= "10000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc10" >
2026-03-24 15:04:02 +08:00
<config default= "5000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "250" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "5000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
2026-04-01 09:46:54 +08:00
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
2026-03-24 15:04:02 +08:00
</configs>
2026-04-01 09:46:54 +08:00
<configs name= "Mfc11" >
<config default= "1000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "50" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc12" >
<config default= "1000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "50" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc13" >
<config default= "5000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "250" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "5000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "HCL" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc14" >
<config default= "500" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "25" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "500" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "SiH4" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc15" >
<config default= "10000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc16" >
<config default= "500" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "25" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "500" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "C2H4" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc17" >
<config default= "10000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "25" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "500" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "C2H4" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc19" >
<config default= "10000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc20" >
<config default= "5000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "250" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "5000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc22" >
<config default= "10000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc23" >
<config default= "5000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "250" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "5000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc25" >
<config default= "10000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "10000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc26" >
<config default= "5000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "250" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "5000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc27" >
<config default= "200000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "5000" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "30000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc28" >
<config default= "30000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "1500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "30000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc29" >
<config default= "15000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "750" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "15000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc31" >
<config default= "20000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "1000" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "20000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc32" >
<config default= "20000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "1000" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "20000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc33" >
<config default= "5000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "250" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "5000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc35" >
<config default= "30000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "1500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "30000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc36" >
<config default= "30000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "30000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc37" >
<config default= "20000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "20000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc38" >
<config default= "20000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "20000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc40" >
<config default= "100000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "10000" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "200000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc41" >
<config default= "100000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "10000" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "200000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc42" >
<config default= "100000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "10000" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "200000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc43" >
<config default= "100000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "100000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc44" >
<config default= "100000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "100000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "Mfc45" >
<config default= "100000" name= "N2Scale" description= "Scale" max= "1000000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "100000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "H2" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "false" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
</configs>
2026-03-24 15:04:02 +08:00
<configs name= "PC" >
<config default= "10" name= "WarningTime" description= "设置值和反馈值之差超限后,引发警告的延迟时间" max= "300" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "true" />
<config default= "5" name= "WarningRange" description= "(反馈值-设置值)/设置值 * 100% 超过该百分比后,引发警告" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" visible= "true" />
<config default= "10" name= "AlarmTime" description= "设置值和反馈值之差超限后,引发报警的延迟时间" max= "300" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "true" />
<config default= "10" name= "AlarmRange" description= "(反馈值-设置值)/设置值 * 100% 超过该百分比后,引发报警" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" visible= "true" />
<configs name= "PC1" >
<config default= "5000" name= "Scale" description= "Scale" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "1500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "3000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "0" name= "Offset" description= "PC Offset" max= "1000" min= "-1000" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "true" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "PC2" >
<config default= "5000" name= "Scale" description= "Scale" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "1500" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "3000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "0" name= "Offset" description= "PC Offset" max= "1000" min= "-1000" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "true" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "PC3" >
<config default= "5000" name= "Scale" description= "Scale" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "1900" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "3000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "0" name= "Offset" description= "PC Offset" max= "1000" min= "-1000" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "true" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "PC4" >
<config default= "10000" name= "Scale" description= "Scale" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "1200" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "3000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "0" name= "Offset" description= "PC Offset" max= "1000" min= "-1000" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "true" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "PC5" >
<config default= "10000" name= "Scale" description= "Scale" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "1260" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "3000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "0" name= "Offset" description= "PC Offset" max= "1000" min= "-1000" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "true" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "PC6" >
<config default= "10000" name= "Scale" description= "Scale" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "1260" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "3000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "0" name= "Offset" description= "PC Offset" max= "1000" min= "-1000" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "true" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "PC7" >
<config default= "10000" name= "Scale" description= "Scale" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "1260" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "3000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "0" name= "Offset" description= "PC Offset" max= "1000" min= "-1000" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "true" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "PC8" >
<config default= "10000" name= "Scale" description= "Scale" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "1260" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "3000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "0" name= "Offset" description= "PC Offset" max= "1000" min= "-1000" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "true" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
<configs name= "PC9" >
<config default= "30000" name= "Scale" description= "Scale" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "150" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "3000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "0" name= "Offset" description= "PC Offset" max= "1000" min= "-1000" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "true" name= "EnableAlarm" description= "Enable Alarm" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "true" />
</configs>
</configs>
<configs name= "ConfinementRing" >
<config default= "0" name= "UpPos" description= "隔热罩上位置坐标" max= "100" min= "-100" paramter= "" tag= "" unit= "mm" type= "Double" />
<config default= "0" name= "DownPos" description= "隔热罩下位置坐标" max= "100" min= "-100" paramter= "" tag= "" unit= "mm" type= "Double" />
<config default= "180" name= "MoveSpeed" description= "隔热罩移动速度" max= "500" min= "0" paramter= "" tag= "" unit= "mm/min" type= "Double" />
</configs>
<configs name= "DryRun" visible= "false" >
<config default= "false" name= "IsDryRun" description= "是否空跑工艺" max= "" min= "" paramter= "" tag= "" unit= "" visible= "true" type= "Bool" />
<config default= "10" name= "DryRunDelayTime" description= "空跑工艺,保持多长时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "PreProcess" >
<config default= "200" name= "ChamberPressure" description= "反应腔的目标压力" max= "1050" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "10" name= "RampDelayTime" description= "Ramp到目标值所需时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "850" name= "ProcessBeginTempCondition" description= "等待温度到达此数值后开始工艺" max= "1700" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "5" name= "ServoBeforeUpDelay" description= "隔热罩升起前延迟时间" max= "60" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "Process" >
<config default= "-50" name= "TempOffset" description= "温度的偏移量,用于过冲" max= "100" min= "-100" paramter= "" tag= "" unit= "℃" type= "Double" />
</configs>
<configs name= "ChamberDoor" visible= "false" >
<config default= "10" name= "MoveTimeout" description= "开关闸板阀超时时间" max= "100" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "MainPump" visible= "false" >
<config default= "10" name= "StartTimeout" description= "Start Timeout" max= "100" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "10" name= "ResetErrorTimeout" description= "Reset Error Timeout" max= "100" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "Efficiency" >
<config default= "1" name= "TCS-Eff" description= "TCS Bubbling efficiency for recipe" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "TMA-Eff" description= "TMA Bubbling efficiency for recipe" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "TMAFlowRatio" description= "TMA流量计算需要乘以的系数" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "TCSFlowRatio" description= "TCS流量计算需要乘以的系数" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "HCLFlowRatio" description= "HCL流量计算需要乘以的系数" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "C2H4/C3H8FlowRatio" description= "C2H4/C3H8流量计算需要乘以的系数" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "SiH4FlowRatio" description= "SiH4流量计算需要乘以的系数" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "PN2FlowRatio" description= "PN2流量计算需要乘以的系数" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "ArFlowRatio" description= "Ar流量计算需要乘以的系数" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "H2FlowRatio" description= "H2流量计算需要乘以的系数" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
</configs>
<configs name= "CoolingWater" >
<config default= "5" name= "WarningOffset" description= "超温警告偏移,当水温超过(报警值-Offset)时,产生警告" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" visible= "false" />
<config default= "5" name= "WarningDelay" description= "设置值和反馈值之差超限后,引发警告的延迟时间" max= "300" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "5" name= "AlarmDelay" description= "设置值和反馈值之差超限后,引发报警的延迟时间" max= "300" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "3" name= "FilterDuration" description= "温度采样值滤波时间,对指定时长内的采样数据求算术平均值作为报警判断" max= "10" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "45" name= "SHFlowTemp" description= "U1 DO196 喷淋头超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "ChamTopFlowTemp" description= "U2 DO197 PM中间法兰超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "ChamMiddleFlow1Temp" description= "U3 DO198 PM腔中部1超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "ChamMiddleFlow2Temp" description= "U4 DO195 PM腔中部2超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "ChamBottomFlowTemp" description= "U5 DO199 PM腔下部超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "Foreline1FlowTemp" description= "U6 DO200 PM腔底部超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "PowerRod1FlowTemp" description= "U7 DO201 下电极超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "PowerRod2FlowTemp" description= "U8 DO202 下电极和磁流体超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "Foreline2FlowTemp" description= "U9 DO203 真空管道和方口法兰超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "ElectrodeWFlowTemp" description= "U10 DO204 侧壁电极超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "Spare1FlowTemp" description= "U11 DO205 TM干泵超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "Spare2FlowTemp" description= "U12 DO207 备用1超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "Spare3FlowTemp" description= "U13 DO208 备用2超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "45" name= "TransformerFlowTemp" description= "U14 DO206 变压器超温报警" max= "90" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
</configs>
<configs name= "IdleService" visible= "false" >
<config default= "false" name= "IdleFirstEnable" description= "IdleService是否启用首次Clean" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "IdlePurgeEnable" description= "IdleService是否启用Purge Clean" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "CountCleanEnable" description= "是否启用每运行多少炉需要执行Recipe" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "" name= "IdleFirstRecipe" description= "IdleService首次运行Recipe的文件名称" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "" name= "IdlePurgeRecipe" description= "IdleService后续运行Recipe的文件名称" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "" name= "CountCleanRecipe" description= "每运行多少炉需要执行Recipe的文件名称" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "60" name= "IdleFirstTime" description= "第一次待机多长时间调用Recipe" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "true" />
<config default= "60" name= "IdlePurgeTime" description= "后续每隔多长时间调用Recipe" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "true" />
<config default= "5" name= "CleanRunCount" description= "每运行多少炉需要执行Clean Recipe" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "true" />
<config default= "0" name= "CurrentRunCount" description= "当前炉计数" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
</configs>
<configs name= "PT" >
<config default= "0" name= "PT1_Offset" description= "PT1 Offset值" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "PT1_K" description= "PT1 K值" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "PT2_Offset" description= "PT2 Offset值" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "PT2_K" description= "PT2 K值" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "PT3_Offset" description= "PT3 Offset值" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "PT3_K" description= "PT3 K值" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "PT4_Offset" description= "PT4 Offset值" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "PT4_K" description= "PT4 K值" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "PT9_Offset" description= "PT9 Offset值" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "PT9_K" description= "PT9 K值" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "PT10_Offset" description= "PT10 Offset值" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "1" name= "PT10_K" description= "PT10 K值" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
</configs>
<configs name= "WaterTemp" >
<config default= "0" name= "U1_Water" description= "SHFlow" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U2_Water" description= "ChamTopFlow" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U3_Water" description= "ChamMiddleFlow1" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U4_Water" description= "ChamMiddleFlow2" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U5_Water" description= "ChamBottomFlow" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U6_Water" description= "Foreline1.Flow" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U7_Water" description= "PowerRod1Flow" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U8_Water" description= "PowerRod2Flow" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U9_Water" description= "Foreline2.Flow" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U10_Water" description= "Electrode-W.Flow" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U11_Water" description= "TMPump1Flow" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U12_Water" description= "Spare1" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U13_Water" description= "Spare2" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "0" name= "U14_Water" description= "TransformerFlow" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" />
</configs>
<configs name= "RotationAlarm" >
<config default= "true" name= "WarningOrAlarm" description= "True:Alarm, False:Warning" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "3" name= "Threshold" description= "Threshold of rotation speed." max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "3" name= "Times" description= "Out of gauge times, calculate one time per second." max= "100" min= "1" paramter= "" tag= "" unit= "" type= "Integer" />
</configs>
<configs name= "LineHeaterTemp" >
<config default= "0" name= "加热带温区1" description= "HeatTMAHigh 温度上限,设为0忽略报警" max= "100" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "70" name= "加热带温区2" description= "HeatTCSPanel 温度上限,设为0忽略报警" max= "100" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "70" name= "加热带温区3" description= "HeatinsidePanel 温度上限,设为0忽略报警" max= "100" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "70" name= "加热带温区4" description= "HeatoutsidePane 温度上限,设为0忽略报警" max= "100" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "70" name= "加热带温区5" description= "HeatoutsideSH 温度上限,设为0忽略报警" max= "100" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "70" name= "加热带温区6" description= "HeatLeakBypass 温度上限,设为0忽略报警" max= "100" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "0" name= "PumpLineTempLimt" description= "PumpLineTempLimt 温度上限,设为0忽略报警" max= "200" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "Warning" name= "PumpLineTempAlarm" description= "报警等级(加热带温区1-6固定为Warning)" max= "" min= "" paramter= "Warning;Alarm" tag= "ReadOnlySelection" unit= "" type= "String" visible= "true" />
</configs>
<configs name= "TempSensor" >
<config default= "AKunTemp.t3" name= "MiddleTemp" description= "设置Middle温度数据通道,重启生效" max= "" min= "" paramter= "AETemp.t1;AETemp.t2;AETemp.t3;AETemp.t4;AKunTemp.t1;AKunTemp.t2;AKunTemp.t3;AKunTemp.t4;SensorTemp1.t1;SensorTemp2.t1;SensorTemp3.t1;SensorTemp4.t1;StrongTemp1.t1;StrongTemp2.t1;StrongTemp3.t1;StrongTemp4.t1;Disabled" tag= "ReadOnlySelection" unit= "" type= "String" visible= "false" />
<config default= "AKunTemp.t4" name= "OuterTemp" description= "设置Outer温度数据通道,重启生效" max= "" min= "" paramter= "AETemp.t1;AETemp.t2;AETemp.t3;AETemp.t4;AKunTemp.t1;AKunTemp.t2;AKunTemp.t3;AKunTemp.t4;SensorTemp1.t1;SensorTemp2.t1;SensorTemp3.t1;SensorTemp4.t1;StrongTemp1.t1;StrongTemp2.t1;StrongTemp3.t1;StrongTemp4.t1;Disabled" tag= "ReadOnlySelection" unit= "" type= "String" visible= "false" />
<config default= "Disabled" name= "InnerTemp" description= "设置Inner温度数据通道,重启生效" max= "" min= "" paramter= "AETemp.t1;AETemp.t2;AETemp.t3;AETemp.t4;AKunTemp.t1;AKunTemp.t2;AKunTemp.t3;AKunTemp.t4;SensorTemp1.t1;SensorTemp2.t1;SensorTemp3.t1;SensorTemp4.t1;StrongTemp1.t1;StrongTemp2.t1;StrongTemp3.t1;StrongTemp4.t1;Disabled" tag= "ReadOnlySelection" unit= "" type= "String" visible= "false" />
<config default= "Disabled" name= "Middle" description= "设置Middle温度数据通道,重启生效" max= "" min= "" paramter= "AETemp.CH1;AETemp.CH2;AETemp.CH3;AETemp.CH4;AKunTemp.CH1;AKunTemp.CH2;AKunTemp.CH3;AKunTemp.CH4;SensorTemp1.CH1;SensorTemp2.CH1;SensorTemp3.CH1;SensorTemp4.CH1;StrongTemp1.CH1;StrongTemp2.CH1;StrongTemp3.CH1;StrongTemp4.CH1;Disabled" tag= "ReadOnlySelection" unit= "" type= "String" />
<config default= "Disabled" name= "Outer" description= "设置Outer温度数据通道,重启生效" max= "" min= "" paramter= "AETemp.CH1;AETemp.CH2;AETemp.CH3;AETemp.CH4;AKunTemp.CH1;AKunTemp.CH2;AKunTemp.CH3;AKunTemp.CH4;SensorTemp1.CH1;SensorTemp2.CH1;SensorTemp3.CH1;SensorTemp4.CH1;StrongTemp1.CH1;StrongTemp2.CH1;StrongTemp3.CH1;StrongTemp4.CH1;Disabled" tag= "ReadOnlySelection" unit= "" type= "String" />
<config default= "Disabled" name= "Inner" description= "设置Inner温度数据通道,重启生效" max= "" min= "" paramter= "AETemp.CH1;AETemp.CH2;AETemp.CH3;AETemp.CH4;AKunTemp.CH1;AKunTemp.CH2;AKunTemp.CH3;AKunTemp.CH4;SensorTemp1.CH1;SensorTemp2.CH1;SensorTemp3.CH1;SensorTemp4.CH1;StrongTemp1.CH1;StrongTemp2.CH1;StrongTemp3.CH1;StrongTemp4.CH1;Disabled" tag= "ReadOnlySelection" unit= "" type= "String" />
<config default= "None" name= "FilterType" description= "温度滤波器类型" max= "0" min= "0" paramter= "None;MAF" tag= "ReadOnlySelection" unit= "" type= "String" />
<configs name= "Filters" >
<configs name= "MAF" >
<config default= "1000" name= "WindowSize" description= "移动平均滤波器滤波窗口" max= "120000" min= "0" paramter= "" tag= "" unit= "ms" type= "Integer" />
</configs>
<configs name= "FIR" >
<config default= "128" name= "Order" description= "FIR滤波器阶数" max= "10240" min= "0" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "1;1;1;1;1;1;" name= "Coefficients" description= "FIR滤波器系数;系数个数需和阶数匹配,每个系数之间使用;分隔" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
</configs>
<configs name= "Kalman" >
<config default= "1;1;1;1;1;1;" name= "Coefficients" description= "卡尔曼滤波器系数;每个系数之间使用;分隔" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
</configs>
</configs>
</configs>
</configs>
</configs>
<configs name= "TM" >
<config default= "false" name= "BypassInterlock" description= "Bypass Interlock" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "false" name= "BypassEnableTable" description= "Bypass EnableTable" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "200" name= "ProcessPressure" description= "传盘压力基准" max= "1200" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "20" name= "VacuumPressureBaseOffset" description= "传盘压力Offset" max= "1200" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "127.0.0.1:102" name= "SiemensIP" description= "Siemens IP Address,Default IP: 192.168.1.102" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "S1500" name= "SiemensType" visible= "false" description= "Siemens Type" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "960" name= "AtmPressureBase" description= "判断大气压的时候,压力值需要大于该值" max= "1200" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "1" name= "VacuumPressureBase" description= "判断真空的时候,压力值需要小于该值" max= "1200" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" visible= "false" />
<config default= "1100" name= "VentMaxPressure" description= "腔体到达此压力自动关闭Vent阀门" max= "1200" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "5" name= "MaxPressureDiffOpenSlitValve" description= "闸板阀允许打开的最大压力差" max= "1200" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "5" name= "TMPressureBigThanPM" description= "闸板阀打开前TM的压力需要高于PM的数值" max= "1200" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "true" name= "NeedPressureBalance" visible= "false" description= "开闸板阀是否需要压力平衡" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "1100" name= "ForelinePressureBase" description= "抽气的时候,Foreline压力值需要小于该值" max= "10000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" visible= "false" />
<config default= "true" name= "RunPumpRoutineEventBelowBasePressure" description= "即使在低压,仍然继续抽" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "false" />
<config default= "100" name= "WaitForelinePressureTimeout" description= "抽气的时候,foreline压力多久达不到底压,则报错" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "600" name= "WaitPumpTimeout" description= "等待真空泵的时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "true" name= "PM1SlitValveEnabled" description= "PM1是否参与控制slitvalve" max= "" min= "" paramter= "" tag= "" unit= "" visible= "false" type= "Bool" />
<config default= "true" name= "PM2SlitValveEnabled" description= "PM2是否参与控制slitvalve" max= "" min= "" paramter= "" tag= "" unit= "" visible= "false" type= "Bool" />
<config default= "true" name= "LoadLockSlitValveEnabled" description= "LoadLock是否参与控制slitvalve" max= "" min= "" paramter= "" tag= "" unit= "" visible= "false" type= "Bool" />
<config default= "true" name= "UnLoadSlitValveEnabled" description= "UnLoad是否参与控制slitvalve" max= "" min= "" paramter= "" tag= "" unit= "" visible= "false" type= "Bool" />
<config default= "true" name= "BufferSlitValveEnabled" description= "Buffer是否参与控制slitvalve" max= "" min= "" paramter= "" tag= "" unit= "" visible= "false" type= "Bool" />
<config default= "false" name= "IsVerifyValveEnabled" description= "TM是否set slit valve" max= "0" min= "0" paramter= "" tag= "" unit= "" visible= "false" type= "Bool" />
<config default= "100" name= "LoadLockWarnTemp" description= "LoadLock高于此温度报警" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" visible= "false" />
<config default= "100" name= "BufferWarnTemp" description= "Buffer高于此温度报警" max= "2000" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" visible= "false" />
<config default= "5" name= "OpenSlitValveDelayTimeForPM" description= "与PM的连通阀打开后等待多长时间开启闸板阀" max= "120" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "10000" name= "MFCFlowWhenV77Open" description= "与PM的连通时MFC60流量设置" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Double" />
<config default= "10" name= "HomeTimeout" description= "home time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "8" name= "TrayNum" description= "Tray num for Coating(统计Coating时最多Tray的数量)" max= "100" min= "1" paramter= "" tag= "" unit= "" type= "Integer" />
<configs name= "Home" >
<config default= "250" name= "RoutineTimeOut" description= "Routine超时时间" max= "3000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "Pump" >
<config default= "200" name= "SlowFastPumpSwitchPressure" description= "抽气的时候,快慢阀门切换的压力值" max= "600" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "1" name= "PumpBasePressure" description= "抽气的底压" max= "100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "300" name= "FastPumpTimeout" description= "快抽抽气超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "300" name= "PumpSlowTimeout" description= "慢抽抽气超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "10" name= "PumpDelayTime" description= "抽气到底压后,继续抽气多长时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "600" name= "RoutineTimeOut" description= "Routine超时时间" max= "3000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "Vent" >
<config default= "200" name= "SlowFastVentSwitchPressure" description= "充气的时候,快慢阀门切换的压力值" max= "600" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "980" name= "VentBasePressure" description= "充气的底压" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "500" name= "VentTimeout" description= "慢充快充总的Vent超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "3" name= "VentDelayTime" description= "充气到大气压后,继续充气多长时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "15000" name= "Mfc60Default1" description= "Mfc60慢充流量" max= "30000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "25000" name= "Mfc60Default2" description= "Mfc60快充流量" max= "30000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "600" name= "RoutineTimeOut" description= "Routine超时时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "100" name= "BufferMaxTemp" visible= "false" description= "TM Vent需满足Buffer腔温度不超过此设定值" max= "1000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
</configs>
<configs name= "Purge" >
<config default= "3" name= "CyclePurgeCount" description= "来回循环的次数" max= "100" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "200" name= "SlowFastPumpSwitchPressure" description= "抽气的时候,快慢阀门切换的压力值" max= "600" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "0" name= "PumpBasePressure" description= "抽气的底压" max= "1000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "10" name= "PumpDelayTime" description= "抽气到底压后,继续抽气多长时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "100" name= "PumpTimeOut" description= "抽气超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "980" name= "VentBasePressure" description= "充气的底压" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "10" name= "VentDelayTime" description= "充气到大气压后,继续充气多长时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "500" name= "VentTimeout" description= "慢充快充总的Vent超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "200" name= "SlowFastVentSwitchPressure" description= "充气的时候,快慢阀门切换的压力值" max= "600" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "15000" name= "Mfc60Default1" description= "Mfc60慢充流量" max= "30000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "25000" name= "Mfc60Default2" description= "Mfc60快充流量" max= "30000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "3000" name= "RoutineTimeOut" description= "Routine超时时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "LeakCheck" >
<config default= "1" name= "CyclePurgeCount" description= "来回循环的次数" max= "100" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "200" name= "SlowFastPumpSwitchPressure" description= "抽气的时候,快慢阀门切换的压力值" max= "600" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "1" name= "PumpBasePressure" description= "抽气的底压" max= "1000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "10" name= "PumpDelayTime" description= "抽气到底压后,继续抽气多长时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "980" name= "VentBasePressure" description= "充气的底压" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "1000" name= "VentDelayTime" description= "充气到大气压后,继续充气多长时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "300" name= "PumpTimeOut" description= "抽气超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "300" name= "LeakCheckDelayTime" description= "LeakCheck时,保持多长时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "0.5" name= "LeakSpec" description= "LeakSpec" max= "100" min= "0" paramter= "" tag= "" unit= "mbar/min" type= "Double" />
<config default= "3000" name= "RoutineTimeOut" description= "Routine超时时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "PressureBalance" >
<config default= "5" name= "PidP" description= "Balance Pressure For Proportional" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" visible= "false" />
<config default= "9" name= "PidI" description= "Balance Pressure For Integral" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Double" visible= "false" />
<config default= "-2" name= "PidD" description= "Balance Pressure For Derivative" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" visible= "false" />
<config default= "300" name= "BalanceTimeout" description= "PID Timeout" max= "3000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "1000" name= "SleepTime" description= "PID Sleep Time" max= "3000" min= "1" paramter= "" tag= "" unit= "ms" type= "Integer" visible= "false" />
<config default= "50" name= "SuccessCount" description= "Success Count" max= "3000" min= "1" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "10" name= "BalanceMaxDiffPressure" description= "Max Difference Pressure For current and Target Module" max= "100" min= "-100" paramter= "" tag= "" unit= "" type= "Double" visible= "true" />
<config default= "300" name= "BalancePressure" description= "Balance Pressure" max= "1000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "300" name= "VentTimeout" description= "Vent Timeout" max= "3000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "50" name= "MfcFlow" description= "MfcFlow" max= "100000" min= "1" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "300" name= "WaitPressureAboveSetPointTimeout" description= "Wait Pressure AboveSetPointTimeout" max= "3000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "MFC" >
<config default= "1.5" name= "MinScale" description= "MFC Min Scale" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
<config default= "10" name= "WarningTime" description= "设置值和反馈值之差超限后,引发警告的延迟时间" max= "300" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "true" />
<config default= "5" name= "WarningRange" description= "(反馈值-设置值)/设置值 * 100% 超过该百分比后,引发警告" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" visible= "true" />
<config default= "10" name= "AlarmTime" description= "设置值和反馈值之差超限后,引发报警的延迟时间" max= "300" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "true" />
<config default= "10" name= "AlarmRange" description= "(反馈值-设置值)/设置值 * 100% 超过该百分比后,引发报警" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" visible= "true" />
<configs name= "Mfc60" >
<config default= "30000" name= "N2Scale" description= "Scale" max= "30000" min= "0" paramter= "" tag= "" unit= "sccm" type= "Double" />
<config default= "10000" name= "DefaultSetPoint" description= "DefaultSetPoint" max= "30000" min= "0" paramter= "" tag= "" unit= "" type= "Double" />
<config default= "Ar" name= "GasName" description= "Gas Name" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "true" name= "EnableAlarm" description= "Enable Alarm" max= "0" min= "0" paramter= "" tag= "" unit= "" type= "Bool" />
</configs>
</configs>
</configs>
<configs name= "TMRobot" >
<config default= "30" name= "PickTimeout" description= "pick time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" visible= "true" />
<config default= "30" name= "GotoTimeout" description= "Goto time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "30" name= "HomeTimeout" description= "home time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "30" name= "MotionTimeout" description= "Motion Time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "127.0.0.1:1102" name= "Address" description= "Robot IP,Defalut IP:192.168.1.101" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "30" name= "PlaceTimeout" description= "place time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" visible= "true" />
<config default= "30" name= "ExtendTimeout" description= "extend time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "30" name= "RetractTimeout" description= "retract time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "30" name= "ConnectTimeout" description= "connect time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "false" name= "EnableLogMessage" description= "Enable Log Message" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "true" name= "Blade1Enable" description= "Blade1 Enable" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "false" />
<config default= "true" name= "Blade2Enable" description= "Blade2 Enable" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "false" />
<config default= "1" name= "Blade2Slots" description= "Slot数目" max= "25" min= "1" paramter= "" tag= "" unit= "" type= "Integer" visible= "false" />
<config default= "1" name= "RobotSpeed" description= "Robot速度, 1low 2 middle 3=high" max= "3" min= "1" paramter= "" tag= "" unit= "" type= "Integer" visible= "false" />
</configs>
<configs name= "EFEM" visible= "false" >
<config default= "1020" name= "AtmPressureBase" description= "判断大气压的时候,压力值需要大于该值" max= "1200" min= "900" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "30" name= "SlitValveMotionTimeout" description= "闸板阀打开超时时间" max= "100" min= "1" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "50" name= "MaxPressureDiffOpenSlitValve" description= "闸板阀允许打开的最大压力差" max= "1200" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
</configs>
<configs name= "WaferRobot" visible= "false" >
<config default= "20" name= "PickTimeout" description= "pick time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "20" name= "PlaceTimeout" description= "place time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "20" name= "GotoTimeout" description= "Goto time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "20" name= "HomeTimeout" description= "home time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "20" name= "MotionTimeout" description= "Motion Time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "127.0.0.1:1103" name= "Address" description= "Robot ip,default 192.168.1.110 : 8001" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "20" name= "ExtendTimeout" description= "extend time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "20" name= "RetractTimeout" description= "retract time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "10" name= "ConnectTimeout" description= "connect time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "true" name= "EnableLogMessage" description= "Enable Log Message" max= "0" min= "0" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "true" name= "Blade1Enable" description= "Blade1 Enable" max= "0" min= "0" paramter= "" tag= "" unit= "" type= "Bool" visible= "false" />
<config default= "true" name= "Blade2Enable" description= "Blade2 Enable" max= "0" min= "0" paramter= "" tag= "" unit= "" type= "Bool" visible= "false" />
</configs>
<configs name= "TrayRobot" visible= "false" >
<config default= "20" name= "PickTimeout" description= "pick time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "20" name= "PlaceTimeout" description= "place time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "20" name= "GotoTimeout" description= "Goto time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "20" name= "HomeTimeout" description= "home time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "20" name= "MotionTimeout" description= "Motion Time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "127.0.0.1:1104" name= "Address" description= "Robot ip,default 192.168.1.111 : 8001" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "20" name= "ExtendTimeout" description= "extend time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "20" name= "RetractTimeout" description= "retract time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "10" name= "ConnectTimeout" description= "connect time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "true" name= "EnableLogMessage" description= "Enable Log Message" max= "0" min= "0" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "true" name= "Blade1Enable" description= "Blade1 Enable" max= "0" min= "0" paramter= "" tag= "" unit= "" type= "Bool" visible= "false" />
<config default= "true" name= "Blade2Enable" description= "Blade2 Enable" max= "0" min= "0" paramter= "" tag= "" unit= "" type= "Bool" visible= "false" />
<config default= "9000" name= "PickRMoveDistance" description= "PickRMoveDistance" max= "100000" min= "-100000" paramter= "" tag= "" unit= "" visible= "true" type= "Integer" />
<config default= "-9000" name= "PlaceRMoveDistance" description= "PlaceRMoveDistance" max= "100000" min= "-100000" paramter= "" tag= "" unit= "" visible= "true" type= "Integer" />
</configs>
<configs name= "LoadLock" >
<config default= "false" name= "EnableLift" description= "是否带升降" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "false" />
<config default= "true" name= "IsVerifyDoorEnabled" visible= "false" description= "TM是否set atm door" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "120" name= "PostTransferTimeout" description= "post transfer time out" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "960" name= "AtmPressureBase" description= "判断大气压的时候,压力值需要大于该值" max= "1200" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "302" name= "VacuumPressureBase" description= "判断真空的时候,压力值需要小于该值" max= "1200" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" visible= "true" />
<config default= "1100" name= "VentMaxPressure" description= "腔体到达此压力自动关闭Vent阀门" max= "1200" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "0.5" name= "ForelinePressureBase" visible= "false" description= "抽气的时候,Foreline压力值需要小于该值" max= "1200" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "true" name= "RunPumpRoutineEventBelowBasePressure" visible= "false" description= "即使在低压,仍然继续抽" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "100" name= "WaitForelinePressureTimeout" visible= "false" description= "抽气的时候,foreline压力多久达不到底压,则报错" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "true" name= "IsUpperSlotIn" visible= "false" description= "自动传盘时,上层Slot是否往TM传输" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "0" name= "PressureOffset" visible= "false" description= "压力修正参数" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "2" name= "ATMDoorDelay" visible= "false" description= "Open/Close ATM Door Delay Time" max= "60" min= "0" paramter= "" tag= "" unit= "s" type= "Double" />
<config default= "600" name= "WaitPumpTimeout" description= "等待真空泵的时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "180" name= "DefaultCoolingTime" visible= "false" description= "默认在LL的冷却时间" max= "10000" min= "5" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "100" name= "WarnTemprature" description= "高于此温度需要报Warnning" max= "900" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "10" name= "HomeTimeout" description= "home time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "10" name= "LiftMoveTimeOut" description= "LiftMoveTimeOut" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "10" name= "ClawMoveTimeOut" description= "ClawMoveTimeOut" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "true" name= "EnableCCDCheck" description= "Wafer和Tray组合后是否启用CCD检测" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "false" />
<config default= "true" name= "EnableDistanceSensorCheck" description= "Wafer和Tray组合后是否启用测距Sensor检测" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" visible= "false" />
<config default= "true" name= "TrayPresenceCheckEnable" description= "传盘后检查Load腔Tray是否存在 Sensor" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<configs name= "Home" >
<config default= "250" name= "RoutineTimeOut" description= "Routine超时时间" max= "3000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "Pump" >
<config default= "100" name= "SlowFastPumpSwitchPressure" description= "抽气的时候,快慢阀门切换的压力值" max= "600" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "1" name= "PumpBasePressure" description= "抽气的底压" max= "100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "100" name= "SlowPumpTimeout" description= "慢抽抽气超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "100" name= "FastPumpTimeout" description= "快抽抽气超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "10" name= "PumpDelayTime" description= "抽气到底压后,继续抽气多长时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "250" name= "RoutineTimeOut" description= "Routine超时时间" max= "3000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "Vent" >
<config default= "100" name= "SlowFastVentSwitchPressure" description= "充气的时候,快慢阀门切换的压力值" max= "600" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "980" name= "VentBasePressure" description= "充气的底压" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "100" name= "SlowVentTimeout" description= "慢充气超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "100" name= "FastVentTimeout" description= "快充气超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" visible= "false" />
<config default= "10" name= "VentDelayTime" description= "充气到大气压后,继续充气多长时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "250" name= "RoutineTimeOut" description= "Routine超时时间" max= "3000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "Purge" >
<config default= "3" name= "CyclePurgeCount" description= "来回循环的次数" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "1" name= "PumpBasePressure" description= "抽气的底压" max= "1000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "10" name= "PumpDelayTime" description= "抽气到底压后,继续抽气多长时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "100" name= "PumpTimeOut" description= "抽气超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "980" name= "VentBasePressure" description= "充气的底压" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "3" name= "VentDelayTime" description= "充气到大气压后,继续充气多长时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "100" name= "VentTimeOut" description= "充气超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "3000" name= "RoutineTimeOut" description= "Routine超时时间" max= "3000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "LeakCheck" >
<config default= "1" name= "CyclePurgeCount" description= "来回循环的次数" max= "100" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "1" name= "PumpBasePressure" description= "抽气的底压" max= "100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "980" name= "VentBasePressure" description= "充气的底压" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "3" name= "PumpDelayTime" description= "抽气到底压后,继续抽气多长时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "300" name= "LeakCheckDelayTime" description= "LeakCheck时,保持多长时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "0.5" name= "LeakSpec" description= "LeakSpec" max= "100" min= "0" paramter= "" tag= "" unit= "mbar/min" type= "Double" />
<config default= "3000" name= "RoutineTimeOut" description= "Routine超时时间" max= "10000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "LoadRotation" visible= "false" >
<config default= "0" name= "CCD1Pos" description= "CCD拍照位置1" max= "360" min= "-360" paramter= "" tag= "" unit= "°" type= "Double" />
<config default= "0" name= "CCD2Pos" description= "CCD拍照位置2" max= "360" min= "-360" paramter= "" tag= "" unit= "°" type= "Double" />
<config default= "0" name= "HomeOffset" description= "LoadRotation旋转电机原点偏移量" max= "360" min= "-360" paramter= "" tag= "" unit= "°" type= "Double" />
<config default= "1" name= "MoveHomeSpeed" description= "Load旋转电机寻找相对原点转速" max= "360" min= "0" paramter= "" tag= "" unit= "rpm" type= "Double" />
<config default= "1" name= "MovePosSpeed" description= "Load旋转电机移动位置转速" max= "360" min= "0" paramter= "" tag= "" unit= "rpm" type= "Double" />
<config default= "60" name= "RotationTimeOut" description= "RotationTimeOut" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "95" name= "DistanceSensorOKRatio" description= "测距Sensor OK百分比" max= "100" min= "0" paramter= "" tag= "" unit= "%" type= "Double" />
</configs>
</configs>
<configs name= "UnLoad" visible= "false" >
<config default= "false" name= "EnableLift" description= "是否带升降" max= "0" min= "0" paramter= "" tag= "" unit= "" visible= "false" type= "Bool" />
<config default= "true" name= "IsVerifyDoorEnabled" description= "TM是否set atm door" max= "0" min= "0" paramter= "" tag= "" unit= "" visible= "true" type= "Bool" />
<config default= "120" name= "PostTransferTimeout" description= "post transfer time out" max= "1000" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "960" name= "AtmPressureBase" description= "判断大气压的时候,压力值需要大于该值" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "302" name= "VacuumPressureBase" description= "判断真空的时候,压力值需要小于该值" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" visible= "false" />
<config default= "1100" name= "VentMaxPressure" description= "腔体到达此压力自动关闭Vent阀门" max= "1500" min= "800" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "0.5" name= "ForelinePressureBase" description= "抽气的时候,Foreline压力值需要小于该值" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "true" name= "RunPumpRoutineEventBelowBasePressure" description= "即使在低压,仍然继续抽" max= "0" min= "0" paramter= "" tag= "" unit= "" visible= "true" type= "Bool" />
<config default= "100" name= "WaitForelinePressureTimeout" visible= "false" description= "抽气的时候,foreline压力多久达不到底压,则报错" max= "1100" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "true" name= "IsUpperSlotIn" description= "自动传盘时,上层Slot是否往TM传输" max= "0" min= "0" paramter= "" tag= "" unit= "" visible= "false" type= "Bool" />
<config default= "0" name= "PressureOffset" visible= "false" description= "压力修正参数" max= "100" min= "0" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "2" name= "ATMDoorDelay" visible= "false" description= "Open/Close ATM Door Delay Time" max= "60" min= "0" paramter= "" tag= "" unit= "s" type= "Double" />
<config default= "600" name= "WaitPumpTimeout" description= "等待真空泵的时间" max= "9999" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<!--<config default="180" name="DefaultCoolingTime" description="默认在Unload的冷却时间" max="9999" min="0" paramter="" tag="" unit="s" type="Integer" />-->
<config default= "100" name= "WarnTemprature" description= "高于此温度需要报Warnning" max= "900" min= "0" paramter= "" tag= "" unit= "s" type= "Double" />
<config default= "10" name= "HomeTimeout" description= "home time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "10" name= "LiftMoveTimeOut" description= "LiftMoveTimeOut" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "10" name= "ClawMoveTimeOut" description= "ClawMoveTimeOut" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<configs name= "Home" >
<config default= "250" name= "RoutineTimeOut" description= "Routine超时时间" max= "3000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "Pump" >
<config default= "100" name= "SlowFastPumpSwitchPressure" description= "抽气的时候,快慢阀门切换的压力值" max= "600" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "1" name= "PumpBasePressure" description= "抽气的底压" max= "1000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "100" name= "SlowPumpTimeout" description= "慢抽抽气超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "100" name= "FastPumpTimeout" description= "快抽抽气超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "10" name= "PumpDelayTime" description= "抽气到底压后,继续抽气多长时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "250" name= "RoutineTimeOut" description= "Routine超时时间" max= "3000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "Vent" >
<config default= "100" name= "SlowFastVentSwitchPressure" description= "充气的时候,快慢阀门切换的压力值" max= "600" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "980" name= "VentBasePressure" description= "充气的底压" max= "1100" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "100" name= "SlowVentTimeout" description= "慢充气超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "100" name= "FastVentTimeout" description= "快充气超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "10" name= "VentDelayTime" description= "充气到大气压后,继续充气多长时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "250" name= "RoutineTimeOut" description= "Routine超时时间" max= "3000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "Purge" >
<config default= "3" name= "CyclePurgeCount" description= "来回循环的次数" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "1" name= "PumpBasePressure" description= "抽气的底压" max= "1000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "10" name= "PumpDelayTime" description= "抽气到底压后,继续抽气多长时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "100" name= "PumpTimeOut" description= "抽气超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "980" name= "VentBasePressure" description= "充气的底压" max= "1000" min= "0" paramter= "" tag= "" unit= "mbar" type= "Double" />
<config default= "3" name= "VentDelayTime" description= "充气到大气压后,继续充气多长时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "100" name= "VentTimeOut" description= "充气超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "3000" name= "RoutineTimeOut" description= "Routine超时时间" max= "3000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "LeakCheck" >
<config default= "1" name= "CyclePurgeCount" description= "来回循环的次数" max= "100" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "300" name= "PumpTimeout" description= "Pump超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "300" name= "VentTimeout" description= "Vent超时时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "10" name= "LoopPumpDelayTime" description= "循环抽气到底压后保持时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "10" name= "LoopVentDelayTime" description= "循环充气到高压后保持时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "3" name= "PumpDelayTime" description= "抽气到底压后,继续抽气多长时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "300" name= "LeakCheckDelayTime" description= "LeakCheck时,保持多长时间" max= "1000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "0.5" name= "LeakSpec" description= "LeakSpec" max= "100" min= "0" paramter= "" tag= "" unit= "mbar/min" type= "Double" />
<config default= "3000" name= "RoutineTimeOut" description= "Routine超时时间" max= "3000" min= "0" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
</configs>
<configs name= "Buffer" visible= "false" >
<config default= "100" name= "WarnTemprature" description= "高于此温度需要报Warnning" max= "900" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "100" name= "PickTemprature" description= "从Buffer取盘温度需要低于该数值" max= "900" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
<config default= "900" name= "TMVentBufferTempMax" description= "TM Vent时Buffer温度需低于该数值" max= "900" min= "0" paramter= "" tag= "" unit= "℃" type= "Double" />
</configs>
<configs name= "NSXBreakerII" visible= "false" >
<config default= "false" name= "EnableDevice" description= "NSX Breaker install" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "COM34" name= "Address" description= "NSX Breaker address,default COM34" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "1" name= "DeviceAddress" description= "NSX Breaker device address" max= "1000" min= "0" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "false" name= "EnableLogMessage" description= "NSX Breaker log message" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
</configs>
<!--<configs name="TempOmron"><config default="false" name="EnableDevice" description="Temp Omron install" max="" min="" paramter="" tag="" unit="" type="Bool" /><config default="COM36" name="Address" description="Temp Omron address" max="" min="" paramter="" tag="" unit="" type="String" /><config default="1" name="DeviceAddress" description="Temp Omron device address" max="1000" min="0" paramter="" tag="" unit="" type="Integer" /><config default="false" name="EnableLogMessage" description="Temp Omron log message" max="" min="" paramter="" tag="" unit="" type="Bool" /><config default="1" name="Modules" description="Module Count" max="5" min="0" paramter="" tag="" unit="" type="Integer" /><config default="1" name="TempWarnMaxDiff" description="Max different between actual value and set value" max="90" min="0" paramter="" tag="" unit="" type="Integer" /></configs>-->
<!--<configs name="PMDRYVacuumPump"><config default="false" name="EnableDevice" description="DRYVacuum Pump install" max="" min="" paramter="" tag="" unit="" type="Bool" /><config default="COM41" name="Address" description="DRYVacuum Pump address" max="" min="" paramter="" tag="" unit="" type="String" /><config default="1" name="DeviceAddress" description="DRYVacuum Pump device address" max="1000" min="0" paramter="" tag="" unit="" type="Integer" /><config default="1000" name="DelayTime" description="DRYVacuum Pump Delay When Soft On" max="1000" min="0" paramter="" tag="" unit="" type="Integer" /><config default="false" name="EnableLogMessage" description="DRYVacuum Pump log message" max="" min="" paramter="" tag="" unit="" type="Bool" /></configs>-->
<configs name= "TMDRYVacuumPump" visible= "false" >
<config default= "false" name= "EnableDevice" description= "DRYVacuum Pump install" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "COM45" name= "Address" description= "DRYVacuum Pump address" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "1000" name= "DelayTime" description= "DRYVacuum Pump Delay When Soft On" max= "1000" min= "0" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "1" name= "DeviceAddress" description= "DRYVacuum Pump device address" max= "1000" min= "0" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "false" name= "EnableLogMessage" description= "DRYVacuum Pump log message" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
</configs>
<!--<configs name="NAISServo"><config default="false" name="EnableDevice" description="NAIS Servo install" max="" min="" paramter="" tag="" unit="" type="Bool" /><config default="COM40" name="Address" description="NAIS Servo address" max="" min="" paramter="" tag="" unit="" type="String" /><config default="1" name="DeviceAddress" description="NAIS Servo device address" max="1000" min="0" paramter="" tag="" unit="" type="Integer" /><config default="false" name="EnableLogMessage" description="NAIS Servo log message" max="" min="" paramter="" tag="" unit="" type="Bool" /><config default="120" name="HomeTimeout" description="Home Timeout" max="1000" min="0" paramter="" tag="" unit="s" type="Integer" /><config default="120" name="UpTimeout" description="Up Timeout" max="1000" min="0" paramter="" tag="" unit="s" type="Integer" /><config default="120" name="DownTimeout" description="Down Timeout" max="1000" min="0" paramter="" tag="" unit="s" type="Integer" /></configs>-->
<configs name= "KeyenceCVX300F" visible= "false" >
<config default= "false" name= "EnableDevice" description= "KeyenceCVX300F install" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "192.168.1.130:8500" name= "Address" description= "KeyenceCVX300F IP address,default IP : 192.168.1.130:8500 " max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "8500" name= "Port" description= "KeyenceCVX300F port num" max= "9999999" min= "0" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "1" name= "DeviceAddress" description= "KeyenceCVX300F device address" max= "999" min= "0" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "true" name= "EnableLogMessage" description= "KeyenceCVX300F log message" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
</configs>
<configs name= "HiWinAligner" visible= "false" >
<config default= "false" name= "EnableDevice" description= "HiWin aligner install" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "COM1" name= "Address" description= "HiWin aligner address,default COM36" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "1" name= "DeviceAddress" description= "HiWin aligner device address" max= "999" min= "0" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "true" name= "EnableLogMessage" description= "HiWin aligner log message" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "10" name= "AlignerTimeout" description= "ALigner time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
<config default= "10" name= "AlignerMoveToCenterTimeOut" description= "ALigner time out" max= "600" min= "1" paramter= "" tag= "" unit= "s" type= "Integer" />
</configs>
<configs name= "P116PIDTC" visible= "false" >
<config default= "false" name= "EnableDevice" description= "Temp Omron install" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "COM36" name= "Address" description= "Temp Omron address" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "1" name= "DeviceAddress" description= "Temp Omron device address" max= "1000" min= "0" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "false" name= "EnableLogMessage" description= "Temp Omron log message" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "1" name= "Modules" description= "Module Count" max= "5" min= "0" paramter= "" tag= "" unit= "" type= "Integer" />
<config default= "1" name= "TempWarnMaxDiff" description= "Max different between actual value and set value" max= "90" min= "0" paramter= "" tag= "" unit= "" type= "Integer" />
</configs>
<configs name= "TempSensors" >
<config default= "false" name= "EnableLogMessage" description= "通讯数据Log保存到本地,一般不开启,设置后立即生效" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "500" name= "PollInterval" description= "读取温度的时间间隔" max= "5000" min= "10" paramter= "" tag= "" unit= "ms" type= "Integer" />
<configs name= "AETemp" >
<config default= "false" name= "EnableDevice" description= "AE启用,设置后重启生效" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "192.168.1.104:1001" name= "Address" description= "AE IP address, Default IP: 192.168.1.104:1001" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "true" name= "Channel1" description= "AE通道1启用,重启生效" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "true" name= "Channel2" description= "AE通道2启用,重启生效" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "true" name= "Channel3" description= "AE通道3启用,重启生效" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "true" name= "Channel4" description= "AE通道4启用,重启生效" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
</configs>
<configs name= "AKunTemp" >
<config default= "false" name= "EnableDevice" description= "AKun启用,设置后重启生效" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "127.0.0.1:53888" name= "Address" description= "AKun IP address, Default IP: 127.0.0.1:53888" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "10" name= "ControllerAverageTime" description= "AKun温度平滑时间,AKun间隔/ms采样温度,设置后立即生效" max= "10000" min= "1" paramter= "" tag= "" unit= "ms" type= "Integer" />
</configs>
<configs name= "Sensor" >
<configs name= "SensorTemp1" >
<config default= "false" name= "EnableDevice" description= "Sensor1启用,设置后重启生效" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "COM1" name= "Address" description= "SensorTemp1 COM, Default COM1" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "PM1" name= "PMName" description= "Default Value" max= "" min= "" paramter= "PM1;PM2" tag= "ReadOnlySelection" unit= "" type= "String" />
</configs>
<configs name= "SensorTemp2" >
<config default= "false" name= "EnableDevice" description= "Sensor2启用,设置后重启生效" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "COM2" name= "Address" description= "SensorTemp2 COM, Default COM2" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "PM1" name= "PMName" description= "Default Value" max= "" min= "" paramter= "PM1;PM2" tag= "ReadOnlySelection" unit= "" type= "String" />
</configs>
<configs name= "SensorTemp3" >
<config default= "false" name= "EnableDevice" description= "Sensor3启用,设置后重启生效" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "COM3" name= "Address" description= "SensorTemp3 COM, Default COM3" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "PM2" name= "PMName" description= "Default Value" max= "" min= "" paramter= "PM1;PM2" tag= "ReadOnlySelection" unit= "" type= "String" />
</configs>
<configs name= "SensorTemp4" >
<config default= "false" name= "EnableDevice" description= "Sensor4启用,设置后重启生效" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "COM4" name= "Address" description= "SensorTemp4 COM, Default COM4" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "PM2" name= "PMName" description= "Default Value" max= "" min= "" paramter= "PM1;PM2" tag= "ReadOnlySelection" unit= "" type= "String" />
</configs>
</configs>
<configs name= "Strong" >
<configs name= "StrongTemp1" >
<config default= "false" name= "EnableDevice" description= "Strong1启用,设置后重启生效" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "COM1" name= "Address" description= "StrongTemp1 COM, Default COM1" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "PM1" name= "PMName" description= "Default Value" max= "" min= "" paramter= "PM1;PM2" tag= "ReadOnlySelection" unit= "" type= "String" />
</configs>
<configs name= "StrongTemp2" >
<config default= "false" name= "EnableDevice" description= "Strong2启用,设置后重启生效" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "COM2" name= "Address" description= "StrongTemp2 COM, Default COM2" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "PM1" name= "PMName" description= "Default Value" max= "" min= "" paramter= "PM1;PM2" tag= "ReadOnlySelection" unit= "" type= "String" />
</configs>
<configs name= "StrongTemp3" >
<config default= "false" name= "EnableDevice" description= "Strong3启用,设置后重启生效" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "COM3" name= "Address" description= "StrongTemp3 COM, Default COM3" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "PM2" name= "PMName" description= "Default Value" max= "" min= "" paramter= "PM1;PM2" tag= "ReadOnlySelection" unit= "" type= "String" />
</configs>
<configs name= "StrongTemp4" >
<config default= "false" name= "EnableDevice" description= "Strong4启用,设置后重启生效" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
<config default= "COM4" name= "Address" description= "StrongTemp4 COM, Default COM4" max= "" min= "" paramter= "" tag= "" unit= "" type= "String" />
<config default= "PM2" name= "PMName" description= "Default Value" max= "" min= "" paramter= "PM1;PM2" tag= "ReadOnlySelection" unit= "" type= "String" />
</configs>
</configs>
</configs>
<configs name= "Gem" >
<config default= "false" name= "Enable" description= "SECS/Gem通信启用" max= "" min= "" paramter= "" tag= "" unit= "" type= "Bool" />
</configs>
</root>