refactor: 将Framework库和RT、UI放在同一个解决方案中。
This commit is contained in:
@@ -0,0 +1,211 @@
|
||||
using System.Collections.Generic;
|
||||
using Aitex.Core.RT.Device;
|
||||
using Aitex.Core.RT.Device.Devices;
|
||||
using Aitex.Core.RT.Routine;
|
||||
using MECF.Framework.Common.Equipment;
|
||||
using SicModules.PMs.Routines.Base;
|
||||
|
||||
namespace SicModules.PMs.Routines
|
||||
{
|
||||
public class PMToIsolationRoutine : PMBaseRoutine
|
||||
{
|
||||
private enum RoutineStep
|
||||
{
|
||||
RotationEnable,
|
||||
HeatEnable,
|
||||
VentPumpClose,
|
||||
ArSupply,
|
||||
|
||||
SetGroupB,
|
||||
SetGroupC,
|
||||
SetGroupE,
|
||||
SetGroupF,
|
||||
SetGroupH,
|
||||
SetGroupD,
|
||||
SetGroupG,
|
||||
SetGroupK,
|
||||
|
||||
SetM1to16,
|
||||
SetM2toM45,
|
||||
SetPC,
|
||||
SetGroupI, //V87-96
|
||||
SetM19to38,
|
||||
CloseFinal1,
|
||||
CloseFinal2,
|
||||
CloseEPV2,
|
||||
|
||||
SetGasOut,
|
||||
SetTv,
|
||||
|
||||
SetGasIn1, //V65,V67,V68
|
||||
OpenFinal1, //V91-96
|
||||
SetMfcFinal1, //M32-38
|
||||
SetM19to26,
|
||||
|
||||
SetGasIn2,
|
||||
SetGroupJOpen,
|
||||
|
||||
OpenFinal2,
|
||||
SetMfcFinal2,
|
||||
|
||||
SetEPV1,
|
||||
SetEPV2,
|
||||
SetTVCloseMode,
|
||||
SetTvPositionToZero,
|
||||
SetMFCMode,
|
||||
SetPCMode,
|
||||
|
||||
SetV76,
|
||||
SetV75,
|
||||
SetV30,
|
||||
SetV31,
|
||||
SetV32,
|
||||
SetV35V36,
|
||||
SetGroupV25,
|
||||
SetV65,
|
||||
CloseV68,
|
||||
|
||||
CloseM32M35M37,
|
||||
CloseM36,
|
||||
CloseM38,
|
||||
CloseGasIn1,
|
||||
CloseFinanl1,
|
||||
|
||||
TimeDelay1,
|
||||
TimeDelay2,
|
||||
TimeDelay3,
|
||||
TimeDelay4,
|
||||
TimeDelay5,
|
||||
TimeDelay6,
|
||||
TimeDelay7,
|
||||
TimeDelay8,
|
||||
TimeDelay9,
|
||||
TimeDelay10,
|
||||
TimeDelay11,
|
||||
TimeDelay12,
|
||||
TimeDelay14,
|
||||
TimeDelay18,
|
||||
TimeDelayForEPV1,
|
||||
}
|
||||
|
||||
private PMModule _pm1Module;
|
||||
private IoThrottleValve2 _IoThrottle;
|
||||
|
||||
private List<int> _lstPcList = new List<int> { 1, 2, 3, 4, 5, 6, 7 };
|
||||
|
||||
private int _rotationCloseTimeout = 20; //旋转停止超时
|
||||
private int _IoValueOpenCloseTimeout = 10; //开关超时时间
|
||||
private int _heatTimeOut = 5; //Heat关闭等待Di反馈超时时间
|
||||
|
||||
public PMToIsolationRoutine(ModuleName module, PMModule pm1) : base(module, pm1)
|
||||
{
|
||||
Module = module.ToString();
|
||||
_pm1Module = pm1;
|
||||
Name = "Isolation";
|
||||
|
||||
_IoThrottle = DEVICE.GetDevice<IoThrottleValve2>($"{Module}.TV");
|
||||
}
|
||||
|
||||
public override Result Start(params object[] objs)
|
||||
{
|
||||
Reset();
|
||||
|
||||
Notify("Start");
|
||||
return Result.RUN;
|
||||
}
|
||||
|
||||
|
||||
public override Result Monitor()
|
||||
{
|
||||
try
|
||||
{
|
||||
//CheckRoutineTimeOut();
|
||||
|
||||
//1 关闭V76,打开V75
|
||||
SetIoValueByGroup((int)RoutineStep.SetV76, IoGroupName.V76, false, _IoValueOpenCloseTimeout);
|
||||
SetIoValueByGroup((int)RoutineStep.SetV75, IoGroupName.V75, true, _IoValueOpenCloseTimeout);
|
||||
|
||||
//2 旋转停止,加热停止
|
||||
SetHeatEnable((int)RoutineStep.HeatEnable, false, _heatTimeOut);
|
||||
SetRotationValve((int)RoutineStep.RotationEnable, 0, false, _rotationCloseTimeout);
|
||||
|
||||
//3 关闭V72
|
||||
SetIoValueByGroup((int)RoutineStep.VentPumpClose, IoGroupName.V72, false, _IoValueOpenCloseTimeout);
|
||||
|
||||
//4 打开V30,打开V31,打开V32
|
||||
SetIoValueByGroup((int)RoutineStep.SetV30, IoGroupName.V30, true, _IoValueOpenCloseTimeout);
|
||||
SetIoValueByGroup((int)RoutineStep.SetV31, IoGroupName.V31, true, _IoValueOpenCloseTimeout);
|
||||
SetIoValueByGroup((int)RoutineStep.SetV32, IoGroupName.V32, true, _IoValueOpenCloseTimeout);
|
||||
|
||||
//5 打开V35,打开V36
|
||||
SetIoValueByGroup((int)RoutineStep.SetV35V36, IoGroupName.V35V36, true, _IoValueOpenCloseTimeout);
|
||||
|
||||
//关闭B/C/E/F/H/K 阀门
|
||||
SetIoValueByGroup((int)RoutineStep.SetGroupB, IoGroupName.B, false, _IoValueOpenCloseTimeout);
|
||||
SetIoValueByGroup((int)RoutineStep.SetGroupC, IoGroupName.C, false, _IoValueOpenCloseTimeout);
|
||||
SetIoValueByGroup((int)RoutineStep.SetGroupE, IoGroupName.E, false, _IoValueOpenCloseTimeout);
|
||||
SetIoValueByGroup((int)RoutineStep.SetGroupF, IoGroupName.F, false, _IoValueOpenCloseTimeout);
|
||||
SetIoValueByGroup((int)RoutineStep.SetGroupH, IoGroupName.H, false, _IoValueOpenCloseTimeout);
|
||||
SetIoValueByGroup((int)RoutineStep.SetGroupK, IoGroupName.K, false, _IoValueOpenCloseTimeout);
|
||||
|
||||
////打开V65
|
||||
//SetIoValueByGroup((int)RoutineStep.SetV65, IoGroupName.V65, true, _IoValueOpenCloseTimeout);
|
||||
|
||||
//打开D/G 阀门
|
||||
SetIoValueByGroup((int)RoutineStep.SetGroupD, IoGroupName.D, true, _IoValueOpenCloseTimeout);
|
||||
SetIoValueByGroup((int)RoutineStep.SetGroupG, IoGroupName.G, true, _IoValueOpenCloseTimeout);
|
||||
|
||||
//关闭V68
|
||||
SetIoValueByGroup((int)RoutineStep.CloseV68, IoGroupName.V68, false, _IoValueOpenCloseTimeout);
|
||||
|
||||
//设置MFC和PC的模式
|
||||
SetMfcModeToNormalByGroup((int)RoutineStep.SetMFCMode, MfcGroupName.All);
|
||||
SetPcModeToNormal((int)RoutineStep.SetPCMode, _lstPcList);
|
||||
|
||||
//6 M1-M16设定为default值(M2、M9、M15除外)
|
||||
SetMfcToDefaultByGroup((int)RoutineStep.SetM1to16, MfcGroupName.M1to16, 0);
|
||||
|
||||
//设置所有PC到默认值
|
||||
SetPcToDefault((int)RoutineStep.SetPC, _lstPcList);
|
||||
|
||||
//M2、M9、M15、M19-M45 MFC 5s ramp到0
|
||||
SetMfcByGroup((int)RoutineStep.SetM2toM45, MfcGroupName.M2toM45, 0, 5);
|
||||
|
||||
//7 关闭Final1阀
|
||||
SetIoValueByGroup((int)RoutineStep.CloseFinal1, IoGroupName.Final1, false, _IoValueOpenCloseTimeout);
|
||||
|
||||
//关闭Final2
|
||||
SetIoValueByGroup((int)RoutineStep.CloseFinal2, IoGroupName.Final2, false, _IoValueOpenCloseTimeout);
|
||||
|
||||
//关闭蝶阀
|
||||
SetThrottleToCloseMode((int)RoutineStep.SetTVCloseMode, _IoThrottle, 8);
|
||||
SetThrottleDisable((int)RoutineStep.SetTvPositionToZero, _IoThrottle, 8);
|
||||
TimeDelay((int)RoutineStep.TimeDelay1, 1);
|
||||
|
||||
//关闭EPV2
|
||||
SetIoValueByGroup((int)RoutineStep.CloseEPV2, IoGroupName.EPV2, false, _IoValueOpenCloseTimeout);
|
||||
}
|
||||
catch (RoutineBreakException)
|
||||
{
|
||||
return Result.RUN;
|
||||
}
|
||||
catch (RoutineFaildException)
|
||||
{
|
||||
return Result.FAIL;
|
||||
}
|
||||
|
||||
Notify("Isolation Finished");
|
||||
|
||||
return Result.DONE;
|
||||
}
|
||||
|
||||
public override void Abort()
|
||||
{
|
||||
PmDevice.SetRotationServo(0, 0);
|
||||
|
||||
base.Abort();
|
||||
}
|
||||
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue
Block a user