refactor: 将Framework库和RT、UI放在同一个解决方案中。
This commit is contained in:
@@ -0,0 +1,276 @@
|
||||
using System.Diagnostics;
|
||||
using Aitex.Core.RT.Device;
|
||||
using Aitex.Core.RT.Device.Devices;
|
||||
using Aitex.Core.RT.Event;
|
||||
using Aitex.Core.RT.Routine;
|
||||
using Aitex.Core.RT.SCCore;
|
||||
using MECF.Framework.Common.Equipment;
|
||||
using MECF.Framework.RT.EquipmentLibrary.HardwareUnits.LoadLocks;
|
||||
using MECF.Framework.RT.EquipmentLibrary.HardwareUnits.TMs;
|
||||
using SicModules.Devices;
|
||||
using SicModules.LLs;
|
||||
|
||||
namespace SicModules.TMs.Routines
|
||||
{
|
||||
public class TMPurgeRoutine : TMBaseRoutine
|
||||
{
|
||||
enum RoutineStep
|
||||
{
|
||||
StartLoop,
|
||||
LoopPump,
|
||||
LoopVent,
|
||||
StopLoop,
|
||||
|
||||
//Pump
|
||||
CloseV77,
|
||||
CloseV80,
|
||||
SlowPump,
|
||||
FastPump,
|
||||
VaccumDelay,
|
||||
CloseValves,
|
||||
CLoseSlowValue,
|
||||
|
||||
//Vent
|
||||
CloseV81,
|
||||
CloseV82,
|
||||
SetMFC1,
|
||||
SetMFC2,
|
||||
OpenSlowVent,
|
||||
OpenFastVent,
|
||||
OpenVent,
|
||||
TimeStayATM,
|
||||
CloseSlowVent
|
||||
}
|
||||
|
||||
|
||||
//private TMPumpRoutine _pumpRoutine;
|
||||
//private TMVentRoutine _ventRoutine;
|
||||
private TM _tm;
|
||||
private IoSensor _bufferLid;
|
||||
private IoSensor _tmLid;
|
||||
private Devices.IoPump _pumpType;
|
||||
private LoadLock _ll;
|
||||
private IoInterLockEx _tmIoInterLock;
|
||||
private Stopwatch _swTimer = new Stopwatch();
|
||||
|
||||
private int _routineTimeOut;
|
||||
private int _purgeCount;
|
||||
|
||||
private double _slowFastPumpSwitchPressure;
|
||||
private double _pumpDelayTime;
|
||||
private double _pumpBasePressure;
|
||||
private int _pumpTimeOut;
|
||||
|
||||
private double _ventBasePressure;
|
||||
private double _slowFastVentSwitchPressure;
|
||||
private int _ventTimeOut;
|
||||
|
||||
private double _mfc60Default1;
|
||||
private double _mfc60Default2;
|
||||
|
||||
private IoMFC _mfc60;
|
||||
|
||||
|
||||
private double _ventDelayTime;
|
||||
|
||||
public TMPurgeRoutine()
|
||||
{
|
||||
Module = ModuleName.TM.ToString();
|
||||
Name = "Purge";
|
||||
|
||||
_tm = DEVICE.GetDevice<SicTM>($"{ ModuleName.System.ToString()}.{ Module}");
|
||||
_ll = DEVICE.GetDevice<SicLoadLock>($"LoadLock.LoadLock");
|
||||
_bufferLid = DEVICE.GetDevice<IoSensor>($"Buffer.BufferLidClosed");
|
||||
_tmLid = DEVICE.GetDevice<IoSensor>($"TM.TMLidClosed");
|
||||
_pumpType = DEVICE.GetDevice<Devices.IoPump>($"TM.TMPump1");
|
||||
_tmIoInterLock = DEVICE.GetDevice<IoInterLockEx>("TM.IoInterLock");
|
||||
_mfc60 = DEVICE.GetDevice<IoMFC>($"TM.Mfc60");
|
||||
|
||||
//_pumpRoutine = new TMPumpRoutine();
|
||||
//_ventRoutine = new TMVentRoutine();
|
||||
}
|
||||
|
||||
public override Result Start(params object[] objs)
|
||||
{
|
||||
Reset();
|
||||
|
||||
_purgeCount = SC.GetValue<int>("TM.Purge.CyclePurgeCount");
|
||||
_routineTimeOut = SC.GetValue<int>("TM.Purge.RoutineTimeOut");
|
||||
|
||||
_slowFastPumpSwitchPressure = SC.GetValue<double>("TM.Purge.SlowFastPumpSwitchPressure");
|
||||
_pumpDelayTime = SC.GetValue<int>("TM.Purge.PumpDelayTime");
|
||||
_pumpBasePressure = SC.GetValue<double>("TM.Purge.PumpBasePressure");
|
||||
_pumpTimeOut = SC.GetValue<int>("TM.Purge.PumpTimeOut");
|
||||
|
||||
_ventDelayTime = SC.GetValue<int>("TM.Purge.VentDelayTime");
|
||||
_mfc60Default1 = SC.GetValue<double>("TM.Purge.Mfc60Default1");
|
||||
_mfc60Default2 = SC.GetValue<double>("TM.Purge.Mfc60Default2");
|
||||
|
||||
_slowFastVentSwitchPressure = SC.GetValue<double>("TM.Purge.SlowFastVentSwitchPressure");
|
||||
_ventTimeOut = SC.GetValue<int>("TM.Purge.VentTimeout");
|
||||
_ventBasePressure = SC.GetValue<double>("TM.Purge.VentBasePressure");
|
||||
|
||||
ModuleName[] modules = new ModuleName[] { ModuleName.LoadLock, ModuleName.PM1, ModuleName.PM2 };
|
||||
foreach (var moduleName in modules)
|
||||
{
|
||||
if (!_tm.CheckSlitValveClose(moduleName))
|
||||
{
|
||||
EV.PostAlarmLog(Module, $"Can not Purge, {moduleName} slit valve not closed");
|
||||
return Result.FAIL;
|
||||
}
|
||||
}
|
||||
|
||||
if (!_bufferLid.Value)
|
||||
{
|
||||
EV.PostAlarmLog(Module, $"Can not Purge,Buffer lid is not open");
|
||||
return Result.FAIL;
|
||||
}
|
||||
if (!_tmLid.Value)
|
||||
{
|
||||
EV.PostAlarmLog(Module, $"Can not Purge,TM lid is not open");
|
||||
return Result.FAIL;
|
||||
}
|
||||
if (_pumpType.IsAlarm)
|
||||
{
|
||||
EV.PostAlarmLog(Module, $"can not Purge,TM pump alarm");
|
||||
return Result.FAIL;
|
||||
}
|
||||
if (!_pumpType.IsRunning)
|
||||
{
|
||||
EV.PostAlarmLog(Module, $"can not Purge,TM pump is not running");
|
||||
return Result.FAIL;
|
||||
}
|
||||
if (!_tmIoInterLock.SetTMPurgeRoutineRunning(true, out string reason))
|
||||
{
|
||||
EV.PostAlarmLog(Module, $"can not Purge,{reason}");
|
||||
return Result.FAIL;
|
||||
}
|
||||
|
||||
_tmIoInterLock.DoTmCyclePurgeRoutineSuccessed = false;
|
||||
|
||||
if (SC.GetValue<bool>("System.IsATMMode"))
|
||||
{
|
||||
return Result.DONE;
|
||||
}
|
||||
|
||||
_swTimer.Restart();
|
||||
Notify("Start");
|
||||
return Result.RUN;
|
||||
}
|
||||
|
||||
|
||||
public override Result Monitor()
|
||||
{
|
||||
try
|
||||
{
|
||||
CheckRoutineTimeOut();
|
||||
|
||||
Loop((int)RoutineStep.StartLoop, _purgeCount);
|
||||
|
||||
//ExecuteRoutine((int)RoutineStep.LoopPump, _pumpRoutine);
|
||||
|
||||
//ExecuteRoutine((int)RoutineStep.LoopVent, _ventRoutine);
|
||||
|
||||
//先Pump
|
||||
{
|
||||
//关闭V77
|
||||
CloseTMVent((int)RoutineStep.CloseV77);
|
||||
|
||||
//关闭V80
|
||||
//CloseBufferVent((int)RoutineStep.CloseV80);
|
||||
|
||||
//打开V82,等待压力低于200mbar(可配置)
|
||||
OpenSlowPump((int)RoutineStep.SlowPump, _tm, _slowFastPumpSwitchPressure, _pumpTimeOut);
|
||||
|
||||
//打开V81,压力达到0mbar(可配置)
|
||||
OpenFastPump((int)RoutineStep.FastPump, _tm, _pumpBasePressure, _pumpTimeOut);
|
||||
|
||||
//等待5s(可配置)
|
||||
TimeDelay((int)RoutineStep.VaccumDelay, _pumpDelayTime);
|
||||
|
||||
//关闭
|
||||
CloseFastPump((int)RoutineStep.CloseValves, _tm);
|
||||
|
||||
CloseSlowPump((int)RoutineStep.CLoseSlowValue, _tm);
|
||||
}
|
||||
|
||||
//再Vent
|
||||
{
|
||||
//关闭V81
|
||||
CloseFastPump((int)RoutineStep.CloseV81);
|
||||
|
||||
//关闭V82
|
||||
CloseSlowPump((int)RoutineStep.CloseV82);
|
||||
|
||||
//设定MFC60慢充流量
|
||||
SetMFCToSetPoint((int)RoutineStep.SetMFC1, _mfc60, _mfc60Default1);
|
||||
|
||||
////打开V77,等待压力大于200mbar
|
||||
//OpenSlowVent((int)RoutineStep.OpenSlowVent, _tm, _slowFastVentSwitchPressure, _slowVentTimeout);
|
||||
|
||||
////设定MFC60快充流量
|
||||
//SetMFCToSetPoint((int)RoutineStep.SetMFC2, _mfc60, _mfc60Default2);
|
||||
|
||||
////等待压力大于1020mbar
|
||||
//OpenFastVent((int)RoutineStep.OpenFastVent, _tm, _ventBasePressure, _fastVentTime);
|
||||
|
||||
//充气过程中检查是否到达打开快充流量的条件
|
||||
OpenVent((int)RoutineStep.OpenVent, _tm, _ventBasePressure, _slowFastVentSwitchPressure, _mfc60Default2, _ventTimeOut);
|
||||
|
||||
//等待5s
|
||||
TimeDelay((int)RoutineStep.TimeStayATM, _ventDelayTime);
|
||||
|
||||
//关闭V77
|
||||
CloseSlowVentValve((int)RoutineStep.CloseSlowVent, _tm);
|
||||
}
|
||||
|
||||
EndLoop((int)RoutineStep.StopLoop);
|
||||
|
||||
//关闭V81
|
||||
CloseFastPump((int)RoutineStep.CloseV81);
|
||||
|
||||
//关闭V82
|
||||
CloseSlowPump((int)RoutineStep.CloseV82);
|
||||
|
||||
//关闭V77
|
||||
CloseSlowVentValve((int)RoutineStep.CloseSlowVent, _tm);
|
||||
}
|
||||
catch (RoutineBreakException)
|
||||
{
|
||||
return Result.RUN;
|
||||
}
|
||||
catch (RoutineFaildException)
|
||||
{
|
||||
return Result.FAIL;
|
||||
}
|
||||
|
||||
Notify($"Finished ! Elapsed time: {(int)(_swTimer.ElapsedMilliseconds / 1000)} s");
|
||||
|
||||
_tmIoInterLock.DoTmCyclePurgeRoutineRunning = false;
|
||||
_tmIoInterLock.DoTmCyclePurgeRoutineSuccessed = true;
|
||||
|
||||
return Result.DONE;
|
||||
}
|
||||
|
||||
public override void Abort()
|
||||
{
|
||||
_tmIoInterLock.DoTmCyclePurgeRoutineRunning = false;
|
||||
_tmIoInterLock.DoTmCyclePurgeRoutineSuccessed = false;
|
||||
|
||||
base.Abort();
|
||||
}
|
||||
|
||||
|
||||
private void CheckRoutineTimeOut()
|
||||
{
|
||||
if (_routineTimeOut > 10)
|
||||
{
|
||||
if ((int)(_swTimer.ElapsedMilliseconds / 1000) > _routineTimeOut)
|
||||
{
|
||||
EV.PostAlarmLog(Module, $"Routine TimeOut! over {_routineTimeOut} s");
|
||||
throw (new RoutineFaildException());
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
Reference in New Issue