refactor: 将Framework库和RT、UI放在同一个解决方案中。
This commit is contained in:
+284
@@ -0,0 +1,284 @@
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.Linq;
|
||||
using MECF.Framework.Common.Communications;
|
||||
|
||||
namespace MECF.Framework.RT.EquipmentLibrary.HardwareUnits.Pumps.Hanbell
|
||||
{
|
||||
public abstract class HanbellPumpHandler : HandlerBase
|
||||
{
|
||||
public HanbellPump Device { get; }
|
||||
|
||||
private byte _address;
|
||||
protected byte _command;
|
||||
|
||||
protected HanbellPumpHandler(HanbellPump device, byte address, byte command, byte[] data)
|
||||
: base(BuildMessage(address, command, data))
|
||||
{
|
||||
Device = device;
|
||||
_address = address;
|
||||
_command = command;
|
||||
}
|
||||
|
||||
private static byte[] BuildMessage(byte address, byte command, byte[] data)
|
||||
{
|
||||
List<byte> buffer = new List<byte>();
|
||||
|
||||
//MODBUS TCP
|
||||
buffer.Add(0x00);
|
||||
buffer.Add(0x00);
|
||||
buffer.Add(0x00);
|
||||
buffer.Add(0x00);
|
||||
|
||||
int length = 2 + (data != null ? data.Length:0);
|
||||
buffer.Add((byte)((length >> 8) & 0xFF));
|
||||
buffer.Add((byte)(length & 0xFF));
|
||||
|
||||
|
||||
buffer.Add(address);
|
||||
buffer.Add(command);
|
||||
if (data != null && data.Length > 0)
|
||||
{
|
||||
buffer.AddRange(data);
|
||||
}
|
||||
|
||||
// CRC ??
|
||||
//buffer.Add(CalcSum(buffer, buffer.Count));
|
||||
|
||||
return buffer.ToArray();
|
||||
}
|
||||
|
||||
//host->unit, unit->host(ack), unit->host(csr), host->unit(ack)
|
||||
public override bool HandleMessage(MessageBase msg, out bool transactionComplete)
|
||||
{
|
||||
HanbellPumpMessage response = msg as HanbellPumpMessage;
|
||||
ResponseMessage = msg;
|
||||
|
||||
Device.NoteError(null);
|
||||
if (response.Address != _address || response.FunctionCode != _command)
|
||||
{
|
||||
transactionComplete = false;
|
||||
return false;
|
||||
}
|
||||
|
||||
if (response.IsComplete)
|
||||
{
|
||||
SetState(EnumHandlerState.Completed);
|
||||
transactionComplete = true;
|
||||
return true;
|
||||
}
|
||||
|
||||
transactionComplete = false;
|
||||
return false;
|
||||
}
|
||||
|
||||
|
||||
public void SendAck()
|
||||
{
|
||||
Device.Connection.SendMessage(new byte[] { 0x06 });
|
||||
}
|
||||
|
||||
|
||||
private static byte ModRTU_CRC(byte[] buffer)
|
||||
{
|
||||
//ushort crc = 0xFFFF;
|
||||
// var buf = System.Text.Encoding.UTF8.GetBytes(String.Join(Environment.NewLine, buffer));
|
||||
var buf = buffer;
|
||||
var len = buffer.Length;
|
||||
byte temp = buffer[0];
|
||||
|
||||
for (int i = 1; i < buffer.Length; i++)
|
||||
{
|
||||
temp = (byte)(temp ^ buffer[i]);
|
||||
}
|
||||
return (byte)~temp;
|
||||
}
|
||||
|
||||
}
|
||||
|
||||
public class HanbellPumpRequestRegistersHandler : HanbellPumpHandler
|
||||
{
|
||||
public HanbellPumpRequestRegistersHandler(HanbellPump device, byte address, int startAddress, int registerCount)
|
||||
: base(device, address, 0x03, BuildData(startAddress, registerCount))
|
||||
{
|
||||
Name = "RequestRegisters";
|
||||
}
|
||||
|
||||
private static byte[] BuildData(int startAddress, int registerCount)
|
||||
{
|
||||
return new byte[] { (byte)(startAddress >> 8), (byte)startAddress, (byte)(registerCount >> 8), (byte)registerCount };
|
||||
}
|
||||
public override bool HandleMessage(MessageBase msg, out bool handled)
|
||||
{
|
||||
if (base.HandleMessage(msg, out handled))
|
||||
{
|
||||
var result = msg as HanbellPumpMessage;
|
||||
if (result.Data.Length < 91)//91=data length + registerCount * 2
|
||||
{
|
||||
Device.NoteError("invalid response for command RequestRegisters");
|
||||
}
|
||||
else
|
||||
{
|
||||
//2031
|
||||
var digitalOutputStatus1High = result.Data[61];
|
||||
var digitalOutputStatus1Low = result.Data[62];
|
||||
Device.IsOn = ((digitalOutputStatus1Low & 0x00000002) == 0) || ((digitalOutputStatus1Low & 0x00000001) == 0);
|
||||
Device.NoteDPPower(result.Data[1] * 256 + result.Data[2]);
|
||||
Device.NoteBPPower(result.Data[3] * 256 + result.Data[4]);
|
||||
Device.NoteDPSpeed(result.Data[5] * 256 + result.Data[6]);
|
||||
Device.NoteBPSpeed(result.Data[37] * 256 + result.Data[8]);
|
||||
|
||||
int waring0 = result.Data[45] * 256 + result.Data[46];
|
||||
Device.NoteDPCurrentHigh(waring0 & (1 << 15));
|
||||
Device.NoteBPCurrentHigh(waring0 & (1 << 14));
|
||||
int waring1 = result.Data[47] * 256 + result.Data[48];
|
||||
int waring2 = result.Data[49] * 256 + result.Data[50];
|
||||
int alarm0 = result.Data[51] * 256 + result.Data[52];
|
||||
int alarm1 = result.Data[53] * 256 + result.Data[54];
|
||||
int alarm2 = result.Data[55] * 256 + result.Data[56];
|
||||
|
||||
Device.IsError = ((digitalOutputStatus1Low & 0x0000004) == 0) || ((digitalOutputStatus1Low & 0x000008) == 0) ||
|
||||
waring0 + waring1 + waring2 != 0 || alarm0 + alarm1 + alarm2 != 0;
|
||||
|
||||
//if (waring0 + waring1 + waring2 != 0)
|
||||
//{
|
||||
// Device.NoteError("pump is in warning status");
|
||||
//}
|
||||
|
||||
//if (alarm0 + alarm1 + alarm2 != 0)
|
||||
//{
|
||||
// Device.NoteError("pump is in alarm status");
|
||||
//}
|
||||
}
|
||||
}
|
||||
return true;
|
||||
}
|
||||
}
|
||||
|
||||
public class HanbellPumpStartVaccumPumpHandler : HanbellPumpHandler
|
||||
{
|
||||
public HanbellPumpStartVaccumPumpHandler(HanbellPump device, byte address)
|
||||
: base(device, address, 0x05, BuildData())
|
||||
{
|
||||
Name = "StartVaccumPump";
|
||||
}
|
||||
|
||||
private static byte[] BuildData()
|
||||
{
|
||||
return new byte[] { 0x00,0x0A,0xFF,0x00 };
|
||||
}
|
||||
|
||||
public override bool HandleMessage(MessageBase msg, out bool handled)
|
||||
{
|
||||
if (base.HandleMessage(msg, out handled))
|
||||
{
|
||||
Device.NoteVaccumPumpCompleted(true);
|
||||
}
|
||||
return true;
|
||||
}
|
||||
}
|
||||
public class HanbellPumpStopVaccumPumpHandler : HanbellPumpHandler
|
||||
{
|
||||
public HanbellPumpStopVaccumPumpHandler(HanbellPump device, byte address)
|
||||
: base(device, address, 0x05, BuildData())
|
||||
{
|
||||
Name = "StopVaccumPump";
|
||||
}
|
||||
|
||||
private static byte[] BuildData()
|
||||
{
|
||||
return new byte[] { 0x00, 0x0A, 0x00, 0x00 };
|
||||
}
|
||||
public override bool HandleMessage(MessageBase msg, out bool handled)
|
||||
{
|
||||
if (base.HandleMessage(msg, out handled))
|
||||
{
|
||||
Device.NoteVaccumPumpCompleted(false);
|
||||
}
|
||||
return true;
|
||||
}
|
||||
}
|
||||
public class HanbellPumpStartBPPumpHandler : HanbellPumpHandler
|
||||
{
|
||||
public HanbellPumpStartBPPumpHandler(HanbellPump device, byte address)
|
||||
: base(device, address, 0x05, BuildData())
|
||||
{
|
||||
Name = "StartBPPump";
|
||||
}
|
||||
|
||||
private static byte[] BuildData()
|
||||
{
|
||||
return new byte[] { 0x00, 0x0B, 0xFF, 0x00 };
|
||||
}
|
||||
public override bool HandleMessage(MessageBase msg, out bool handled)
|
||||
{
|
||||
if (base.HandleMessage(msg, out handled))
|
||||
{
|
||||
Device.NoteBPPumpOnOff(true);
|
||||
}
|
||||
return true;
|
||||
}
|
||||
}
|
||||
public class HanbellPumpStopBPPumpHandler : HanbellPumpHandler
|
||||
{
|
||||
public HanbellPumpStopBPPumpHandler(HanbellPump device, byte address)
|
||||
: base(device, address, 0x05, BuildData())
|
||||
{
|
||||
Name = "StopBPPump";
|
||||
}
|
||||
|
||||
private static byte[] BuildData()
|
||||
{
|
||||
return new byte[] { 0x00, 0x0B, 0x00, 0x00 };
|
||||
}
|
||||
|
||||
public override bool HandleMessage(MessageBase msg, out bool handled)
|
||||
{
|
||||
if (base.HandleMessage(msg, out handled))
|
||||
{
|
||||
Device.NoteBPPumpOnOff(false);
|
||||
}
|
||||
return true;
|
||||
}
|
||||
}
|
||||
|
||||
public class HanbellPumpResetHandler : HanbellPumpHandler
|
||||
{
|
||||
public HanbellPumpResetHandler(HanbellPump device, byte address)
|
||||
: base(device, address, 0x05, BuildData())
|
||||
{
|
||||
Name = "Reset";
|
||||
}
|
||||
|
||||
private static byte[] BuildData()
|
||||
{
|
||||
return new byte[] { 0x00, 0x0C, 0xFF, 0x00 };
|
||||
}
|
||||
}
|
||||
|
||||
public class HanbellPumpRawCommandHandler : HanbellPumpHandler
|
||||
{
|
||||
public HanbellPumpRawCommandHandler(HanbellPump device, byte address, string command, string parameter = null)
|
||||
: base(device, address, byte.Parse(command), BuildData(parameter))
|
||||
{
|
||||
}
|
||||
|
||||
private static byte[] BuildData(string parameter)
|
||||
{
|
||||
if (parameter == null)
|
||||
return new byte[] { };
|
||||
|
||||
return parameter.Split(',').Select(para => Convert.ToByte(para,16)).ToArray();
|
||||
}
|
||||
public override bool HandleMessage(MessageBase msg, out bool handled)
|
||||
{
|
||||
base.HandleMessage(msg, out handled);
|
||||
|
||||
var result = msg as HanbellPumpMessage;
|
||||
Device.NoteRawCommandInfo(_command.ToString("X2"), string.Join(",", result.RawMessage.Select(bt => bt.ToString("X2")).ToArray()));
|
||||
return true;
|
||||
}
|
||||
|
||||
|
||||
}
|
||||
}
|
||||
Reference in New Issue
Block a user