refactor: 将Framework库和RT、UI放在同一个解决方案中。
This commit is contained in:
+483
@@ -0,0 +1,483 @@
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.IO.Ports;
|
||||
using System.Linq;
|
||||
using Aitex.Core.RT.Event;
|
||||
using Aitex.Core.RT.Log;
|
||||
using Aitex.Core.RT.SCCore;
|
||||
using Aitex.Core.Util;
|
||||
using MECF.Framework.Common.Communications;
|
||||
using MECF.Framework.RT.EquipmentLibrary.HardwareUnits.Common;
|
||||
|
||||
namespace MECF.Framework.RT.EquipmentLibrary.HardwareUnits.Pumps.PfeifferPumpA100
|
||||
{
|
||||
public class PfeifferPumpA100 : SerialPortDevice, IConnection
|
||||
{
|
||||
public string Address { get { return _address; }}
|
||||
public bool IsConnected { get; }
|
||||
public bool Connect()
|
||||
{
|
||||
return true;
|
||||
}
|
||||
|
||||
public bool Disconnect()
|
||||
{
|
||||
return true;
|
||||
}
|
||||
|
||||
public string PortStatus { get; set; } = "Closed";
|
||||
|
||||
private PfeifferPumpA100Connection _connection;
|
||||
public PfeifferPumpA100Connection Connection
|
||||
{
|
||||
get { return _connection; }
|
||||
}
|
||||
|
||||
private R_TRIG _trigError = new R_TRIG();
|
||||
|
||||
private R_TRIG _trigCommunicationError = new R_TRIG();
|
||||
private R_TRIG _trigRetryConnect = new R_TRIG();
|
||||
|
||||
private PeriodicJob _thread;
|
||||
|
||||
private LinkedList<HandlerBase> _lstHandler = new LinkedList<HandlerBase>();
|
||||
private LinkedList<HandlerBase> _lstMonitorHandler = new LinkedList<HandlerBase>();
|
||||
|
||||
public List<IOResponse> IOResponseList { get; set; } = new List<IOResponse>();
|
||||
|
||||
|
||||
private object _locker = new object();
|
||||
|
||||
private bool _enableLog;
|
||||
private string _address;
|
||||
private string _scRoot;
|
||||
public PfeifferPumpA100(string module, string name, string scRoot, string portName) : base(module, name)
|
||||
{
|
||||
_scRoot = scRoot;
|
||||
PortName = portName;
|
||||
}
|
||||
private void ResetPropertiesAndResponses()
|
||||
{
|
||||
|
||||
foreach (var ioResponse in IOResponseList)
|
||||
{
|
||||
ioResponse.ResonseContent = null;
|
||||
ioResponse.ResonseRecievedTime = DateTime.Now;
|
||||
}
|
||||
}
|
||||
|
||||
public override bool Initialize(string portName)
|
||||
{
|
||||
base.Initialize(portName);
|
||||
|
||||
ResetPropertiesAndResponses();
|
||||
|
||||
if (_connection != null && _connection.IsConnected && PortName == portName)
|
||||
return true;
|
||||
|
||||
if (_connection != null && _connection.IsConnected)
|
||||
_connection.Disconnect();
|
||||
|
||||
PortName = portName;
|
||||
|
||||
_address = SC.GetStringValue($"{_scRoot}.{Module}.{Name}.DeviceAddress");
|
||||
_enableLog = SC.GetValue<bool>($"{_scRoot}.{Module}.{Name}.EnableLogMessage");
|
||||
_connection = new PfeifferPumpA100Connection(PortName);
|
||||
_connection.EnableLog(_enableLog);
|
||||
|
||||
if (_connection.Connect())
|
||||
{
|
||||
PortStatus = "Open";
|
||||
EV.PostInfoLog(Module, $"{Module}.{Name} connected");
|
||||
}
|
||||
|
||||
_thread = new PeriodicJob(100, OnTimer, $"{Module}.{Name} MonitorHandler", true);
|
||||
|
||||
return true;
|
||||
}
|
||||
|
||||
public bool InitConnection(string portName, int bautRate, int dataBits, Parity parity, StopBits stopBits)
|
||||
{
|
||||
|
||||
_connection = new PfeifferPumpA100Connection(portName, bautRate, dataBits, parity, stopBits);
|
||||
|
||||
if (_connection.Connect())
|
||||
{
|
||||
EV.PostInfoLog(Module, $"{Module}.{Name} connected");
|
||||
}
|
||||
|
||||
_thread = new PeriodicJob(100, OnTimer, $"{Module}.{Name} MonitorHandler", true);
|
||||
|
||||
return true;
|
||||
}
|
||||
|
||||
internal void NoteSetParaCompleted()
|
||||
{
|
||||
SetParaCompleted = true;
|
||||
}
|
||||
|
||||
private bool OnTimer()
|
||||
{
|
||||
try
|
||||
{
|
||||
//_connection.MonitorTimeout();
|
||||
|
||||
if (!_connection.IsConnected || _connection.IsCommunicationError)
|
||||
{
|
||||
lock (_locker)
|
||||
{
|
||||
_lstHandler.Clear();
|
||||
}
|
||||
|
||||
_trigRetryConnect.CLK = !_connection.IsConnected;
|
||||
if (_trigRetryConnect.Q)
|
||||
{
|
||||
_connection.SetPortAddress(SC.GetStringValue($"{ScBasePath}.{Name}.Address"));
|
||||
if (!_connection.Connect())
|
||||
{
|
||||
EV.PostAlarmLog(Module, $"Can not connect with {_connection.Address}, {Module}.{Name}");
|
||||
}
|
||||
else
|
||||
{
|
||||
//_lstHandler.AddLast(new PfeifferPumpA100QueryPinHandler(this, _deviceAddress));
|
||||
//_lstHandler.AddLast(new PfeifferPumpA100SetCommModeHandler(this, _deviceAddress, EnumRfPowerCommunicationMode.Host));
|
||||
}
|
||||
}
|
||||
return true;
|
||||
}
|
||||
|
||||
HandlerBase handler = null;
|
||||
if (!_connection.IsBusy)
|
||||
{
|
||||
lock (_locker)
|
||||
{
|
||||
if (_lstHandler.Count == 0)
|
||||
{
|
||||
foreach (var monitorHandler in _lstMonitorHandler)
|
||||
{
|
||||
_lstHandler.AddLast(monitorHandler);
|
||||
}
|
||||
|
||||
}
|
||||
|
||||
if (_lstHandler.Count > 0)
|
||||
{
|
||||
handler = _lstHandler.First.Value;
|
||||
|
||||
_lstHandler.RemoveFirst();
|
||||
}
|
||||
}
|
||||
|
||||
if (handler != null)
|
||||
{
|
||||
_connection.Execute(handler);
|
||||
}
|
||||
}
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
LOG.Write(ex);
|
||||
}
|
||||
|
||||
return true;
|
||||
}
|
||||
|
||||
|
||||
public override void Monitor()
|
||||
{
|
||||
try
|
||||
{
|
||||
//_connection.EnableLog(_enableLog);
|
||||
|
||||
|
||||
_trigCommunicationError.CLK = _connection.IsCommunicationError;
|
||||
if (_trigCommunicationError.Q)
|
||||
{
|
||||
EV.PostAlarmLog(Module, $"{Module}.{Name} communication error, {_connection.LastCommunicationError}");
|
||||
}
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
LOG.Write(ex);
|
||||
}
|
||||
|
||||
}
|
||||
|
||||
|
||||
public override void Reset()
|
||||
{
|
||||
_trigError.RST = true;
|
||||
|
||||
_connection.SetCommunicationError(false, "");
|
||||
_trigCommunicationError.RST = true;
|
||||
|
||||
//_enableLog = SC.GetValue<bool>($"{ScBasePath}.{Name}.EnableLogMessage");
|
||||
|
||||
_trigRetryConnect.RST = true;
|
||||
|
||||
base.Reset();
|
||||
}
|
||||
|
||||
public override bool Home(out string reason)
|
||||
{
|
||||
return base.Home(out reason);
|
||||
}
|
||||
|
||||
|
||||
#region Command Functions
|
||||
|
||||
public void PerformRawCommand(string command)
|
||||
{
|
||||
lock (_locker)
|
||||
{
|
||||
_lstHandler.AddLast(new PfeifferPumpA100RawCommandHandler(this, command, null));
|
||||
}
|
||||
}
|
||||
public void PerformRawCommand(string command, string parameter)
|
||||
{
|
||||
lock (_locker)
|
||||
{
|
||||
_lstHandler.AddLast(new PfeifferPumpA100RawCommandHandler(this, command, parameter));
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
public void EchoOnOff(string parameter)
|
||||
{
|
||||
lock (_locker)
|
||||
{
|
||||
_lstHandler.AddLast(new PfeifferPumpA100SimpleSwitchHandler(this, "ECH", parameter));
|
||||
}
|
||||
}
|
||||
public void PumpOnOff(string parameter)
|
||||
{
|
||||
lock (_locker)
|
||||
{
|
||||
_lstHandler.AddLast(new PfeifferPumpA100SimpleSwitchHandler(this, "SYS", parameter));
|
||||
}
|
||||
}
|
||||
public void SetPumpParameter(string parameter)
|
||||
{
|
||||
lock (_locker)
|
||||
{
|
||||
_lstHandler.AddLast(new PfeifferPumpSetPumpParameterHandler(this, parameter));
|
||||
}
|
||||
}
|
||||
public void SetFullOverhaullAlert(string alertValue)
|
||||
{
|
||||
lock (_locker)
|
||||
{
|
||||
_lstHandler.AddLast(new PfeifferPumpSetPumpParameterHandler(this, "070" + alertValue));
|
||||
}
|
||||
}
|
||||
public void SetFullOverhaullAlarm(string alarmValue)
|
||||
{
|
||||
lock (_locker)
|
||||
{
|
||||
_lstHandler.AddLast(new PfeifferPumpSetPumpParameterHandler(this, "071" + alarmValue));
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
internal void NoteSwitchCompleted(string command, bool value)
|
||||
{
|
||||
if(command== "ECH")
|
||||
SetEchoOnOff = value;
|
||||
else if (command == "SYS")
|
||||
SetPumpOnOff = value;
|
||||
}
|
||||
|
||||
|
||||
public void MonitorRawCommand(bool isSelected, string command)
|
||||
{
|
||||
lock (_locker)
|
||||
{
|
||||
var existHandlers = _lstMonitorHandler.Where(handler => handler.GetType() == typeof(PfeifferPumpA100RawCommandHandler) && ((PfeifferPumpA100Handler)handler)._command == command);
|
||||
if (isSelected)
|
||||
{
|
||||
if (!existHandlers.Any())
|
||||
_lstMonitorHandler.AddFirst(new PfeifferPumpA100RawCommandHandler(this, command, null));
|
||||
}
|
||||
else
|
||||
{
|
||||
if (existHandlers.Any())
|
||||
{
|
||||
_lstMonitorHandler.Remove(existHandlers.First());
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
public void ReadPumpStatus(bool isSelected)
|
||||
{
|
||||
lock (_locker)
|
||||
{
|
||||
var existHandlers = _lstMonitorHandler.Where(handler => handler.GetType() == typeof(PfeifferPumpA100ReadPumpStatusHandler));
|
||||
if (isSelected)
|
||||
{
|
||||
if (!existHandlers.Any())
|
||||
_lstMonitorHandler.AddFirst(new PfeifferPumpA100ReadPumpStatusHandler(this));
|
||||
}
|
||||
else
|
||||
{
|
||||
if (existHandlers.Any())
|
||||
{
|
||||
_lstMonitorHandler.Remove(existHandlers.First());
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
public void ReadSetState(bool isSelected)
|
||||
{
|
||||
lock (_locker)
|
||||
{
|
||||
var existHandlers = _lstMonitorHandler.Where(handler => handler.GetType() == typeof(PfeifferPumpA100ReadSetStateHandler));
|
||||
if (isSelected)
|
||||
{
|
||||
if (!existHandlers.Any())
|
||||
_lstMonitorHandler.AddFirst(new PfeifferPumpA100ReadSetStateHandler(this));
|
||||
}
|
||||
else
|
||||
{
|
||||
if (existHandlers.Any())
|
||||
{
|
||||
_lstMonitorHandler.Remove(existHandlers.First());
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
#endregion
|
||||
|
||||
#region Properties
|
||||
public string Error { get; private set; }
|
||||
|
||||
public bool SetEchoOnOff { get; private set; }
|
||||
public bool SetPumpOnOff { get; private set; }
|
||||
public bool SetParaCompleted { get; private set; }
|
||||
|
||||
public PumpRunStatus PumpRunStatus { get; private set; }
|
||||
public ControlMode ManageMode { get; private set; }
|
||||
public DefectResult FrequencyControlDefect { get; private set; }
|
||||
public DefectResult MotorTempDefect { get; private set; }
|
||||
public DefectResult MaintenanceDefect { get; private set; }
|
||||
public string SFullOverhaull { get; private set; }
|
||||
|
||||
internal void NotePumpStatus(string data)
|
||||
{
|
||||
try
|
||||
{
|
||||
var statusArray = data.ToArray();
|
||||
PumpRunStatus = (PumpRunStatus)int.Parse(statusArray[0].ToString());
|
||||
var management = int.Parse(statusArray[10].ToString());
|
||||
int manageModeValue = management & 1;
|
||||
ManageMode = (ControlMode)manageModeValue;
|
||||
|
||||
FrequencyControlDefect = (DefectResult)int.Parse(statusArray[48].ToString());
|
||||
MotorTempDefect = (DefectResult)int.Parse(statusArray[51].ToString());
|
||||
MaintenanceDefect = (DefectResult)int.Parse(statusArray[55].ToString());
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
NoteError("Invalid Pump Status");
|
||||
LOG.Error($"Invalid Pump Status: {data}, Exception info: {ex}");
|
||||
}
|
||||
|
||||
}
|
||||
|
||||
internal void NoteReadSetState(string data)
|
||||
{
|
||||
try
|
||||
{
|
||||
SFullOverhaull = data.Substring(65, 5);
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
NoteError("Invalid Pump Status");
|
||||
LOG.Error($"Invalid Pump Status: {data}, Exception info: {ex}");
|
||||
}
|
||||
|
||||
}
|
||||
|
||||
|
||||
private int Str2Int(string sValue)
|
||||
{
|
||||
if (string.IsNullOrEmpty(sValue))
|
||||
throw new Exception("empty int value");
|
||||
if(sValue.Length > 1)
|
||||
{
|
||||
sValue = sValue.TrimStart('0');
|
||||
}
|
||||
return int.Parse(sValue);
|
||||
}
|
||||
|
||||
|
||||
#endregion
|
||||
|
||||
|
||||
#region Note Functions
|
||||
private R_TRIG _trigWarningMessage = new R_TRIG();
|
||||
|
||||
|
||||
|
||||
public void NoteError(string reason)
|
||||
{
|
||||
if (reason != null)
|
||||
{
|
||||
_trigWarningMessage.CLK = true;
|
||||
if (_trigWarningMessage.Q)
|
||||
{
|
||||
EV.PostWarningLog(Module, $"{Module}.{Name} error, {reason}");
|
||||
}
|
||||
Error = reason;
|
||||
}
|
||||
else
|
||||
{
|
||||
Error = null;
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
internal void NoteRawCommandInfo(string command, string data)
|
||||
{
|
||||
var curIOResponse = IOResponseList.Find(res => res.SourceCommand == command);
|
||||
if (curIOResponse != null)
|
||||
{
|
||||
IOResponseList.Remove(curIOResponse);
|
||||
}
|
||||
IOResponseList.Add(new IOResponse() { SourceCommand = command, ResonseContent = data, ResonseRecievedTime = DateTime.Now });
|
||||
}
|
||||
|
||||
#endregion
|
||||
}
|
||||
|
||||
public enum PumpRunStatus
|
||||
{
|
||||
Stopped,
|
||||
Running
|
||||
}
|
||||
public enum ValveStatus
|
||||
{
|
||||
Closed,
|
||||
Opened
|
||||
}
|
||||
public enum PumpLLStatus
|
||||
{
|
||||
Off,
|
||||
On
|
||||
}
|
||||
public enum ControlMode
|
||||
{
|
||||
Local,
|
||||
Remote
|
||||
}
|
||||
public enum DefectResult
|
||||
{
|
||||
OK,
|
||||
Warning,
|
||||
Hazard
|
||||
}
|
||||
|
||||
|
||||
}
|
||||
+65
@@ -0,0 +1,65 @@
|
||||
using System.IO.Ports;
|
||||
using Aitex.Core.RT.Log;
|
||||
using MECF.Framework.Common.Communications;
|
||||
|
||||
namespace MECF.Framework.RT.EquipmentLibrary.HardwareUnits.Pumps.PfeifferPumpA100
|
||||
{
|
||||
public class PfeifferPumpA100Message : AsciiMessage
|
||||
{
|
||||
public string Data { get; set; }
|
||||
public string Address { get; set; }
|
||||
}
|
||||
|
||||
public class PfeifferPumpA100Connection : SerialPortConnectionBase
|
||||
{
|
||||
private static string _startLine = "#";
|
||||
private static string _endLine = "\r";
|
||||
|
||||
|
||||
public PfeifferPumpA100Connection(string portName, int baudRate = 9600, int dataBits = 8, Parity parity = Parity.None, StopBits stopBits = StopBits.One)
|
||||
: base(portName, baudRate, dataBits, parity, stopBits, _endLine, true)
|
||||
{
|
||||
|
||||
}
|
||||
|
||||
public override bool SendMessage(string message)
|
||||
{
|
||||
return base.SendMessage(message);
|
||||
}
|
||||
|
||||
protected override MessageBase ParseResponse(string rawText)
|
||||
{
|
||||
PfeifferPumpA100Message msg = new PfeifferPumpA100Message();
|
||||
msg.RawMessage = rawText;
|
||||
|
||||
if (rawText.Length <= 0)
|
||||
{
|
||||
LOG.Error($"empty response");
|
||||
msg.IsFormatError = true;
|
||||
return msg;
|
||||
}
|
||||
if (rawText.Length <= 4)
|
||||
{
|
||||
LOG.Error($"too short response");
|
||||
msg.IsFormatError = true;
|
||||
return msg;
|
||||
}
|
||||
if (rawText[0].ToString() != _startLine || rawText[rawText.Length-1].ToString() != _endLine)
|
||||
{
|
||||
LOG.Error($"invalid format response");
|
||||
msg.IsFormatError = true;
|
||||
return msg;
|
||||
}
|
||||
rawText = rawText.Substring(1, rawText.Length - 2);//remove start char and end char
|
||||
msg.Address = rawText.Substring(0,3);
|
||||
msg.Data = rawText.Substring(4);
|
||||
msg.IsResponse = true;
|
||||
msg.IsAck = true;
|
||||
|
||||
return msg;
|
||||
}
|
||||
|
||||
|
||||
|
||||
}
|
||||
}
|
||||
+172
@@ -0,0 +1,172 @@
|
||||
using MECF.Framework.Common.Communications;
|
||||
|
||||
namespace MECF.Framework.RT.EquipmentLibrary.HardwareUnits.Pumps.PfeifferPumpA100
|
||||
{
|
||||
public abstract class PfeifferPumpA100Handler : HandlerBase
|
||||
{
|
||||
public PfeifferPumpA100 Device { get; }
|
||||
|
||||
public string _command;
|
||||
protected string _parameter;
|
||||
|
||||
|
||||
protected PfeifferPumpA100Handler(PfeifferPumpA100 device, string command,string parameter)
|
||||
: base(BuildMessage(device.Address, command, parameter))
|
||||
{
|
||||
Device = device;
|
||||
_command = command;
|
||||
_parameter = parameter;
|
||||
Name = command;
|
||||
}
|
||||
|
||||
private static string _startLine = "#";
|
||||
private static string _endLine = "\r";
|
||||
private static string BuildMessage(string address, string command, string parameter)
|
||||
{
|
||||
if(string.IsNullOrEmpty(parameter))
|
||||
return _startLine + address + command + _endLine;
|
||||
else
|
||||
return _startLine + address + command + parameter + _endLine;
|
||||
}
|
||||
|
||||
public override bool HandleMessage(MessageBase msg, out bool transactionComplete)
|
||||
{
|
||||
PfeifferPumpA100Message response = msg as PfeifferPumpA100Message;
|
||||
ResponseMessage = msg;
|
||||
|
||||
if (response.IsAck)
|
||||
{
|
||||
SetState(EnumHandlerState.Acked);
|
||||
|
||||
if (response.Address != Device.Address)
|
||||
{
|
||||
Device.NoteError("Invalid address");
|
||||
msg.IsFormatError = true;
|
||||
}
|
||||
else if (response.Data.Contains("ERR"))
|
||||
{
|
||||
Device.NoteError($"Command '{_command}' Error: {response.Data}");
|
||||
msg.IsError = true;
|
||||
}
|
||||
else
|
||||
{
|
||||
SetState(EnumHandlerState.Completed);
|
||||
transactionComplete = true;
|
||||
Device.NoteError(null);
|
||||
return true;
|
||||
}
|
||||
}
|
||||
|
||||
transactionComplete = false;
|
||||
return false;
|
||||
}
|
||||
|
||||
}
|
||||
|
||||
public class PfeifferPumpA100RawCommandHandler : PfeifferPumpA100Handler
|
||||
{
|
||||
public PfeifferPumpA100RawCommandHandler(PfeifferPumpA100 device, string command, string parameter)
|
||||
: base(device, command, parameter)
|
||||
{
|
||||
}
|
||||
public override bool HandleMessage(MessageBase msg, out bool handled)
|
||||
{
|
||||
if(base.HandleMessage(msg, out handled))
|
||||
{
|
||||
var result = msg as PfeifferPumpA100Message;
|
||||
Device.NoteRawCommandInfo(_command, result.RawMessage);
|
||||
}
|
||||
return true;
|
||||
}
|
||||
|
||||
|
||||
}
|
||||
|
||||
public class PfeifferPumpA100SimpleSwitchHandler : PfeifferPumpA100Handler
|
||||
{
|
||||
public PfeifferPumpA100SimpleSwitchHandler(PfeifferPumpA100 device, string command, string parameter)
|
||||
: base(device, command, parameter)
|
||||
{
|
||||
|
||||
}
|
||||
public override bool HandleMessage(MessageBase msg, out bool handled)
|
||||
{
|
||||
if(base.HandleMessage(msg, out handled))
|
||||
{
|
||||
Device.NoteSwitchCompleted(_command, _parameter.Contains("ON"));
|
||||
}
|
||||
return true;
|
||||
}
|
||||
}
|
||||
|
||||
public class PfeifferPumpSetPumpParameterHandler : PfeifferPumpA100Handler
|
||||
{
|
||||
public PfeifferPumpSetPumpParameterHandler(PfeifferPumpA100 device, string parameter)
|
||||
: base(device, "SET", parameter)
|
||||
{
|
||||
|
||||
}
|
||||
public override bool HandleMessage(MessageBase msg, out bool handled)
|
||||
{
|
||||
if (base.HandleMessage(msg, out handled))
|
||||
{
|
||||
Device.NoteSetParaCompleted();
|
||||
}
|
||||
return true;
|
||||
}
|
||||
}
|
||||
|
||||
public class PfeifferPumpA100ReadPumpStatusHandler : PfeifferPumpA100Handler
|
||||
{
|
||||
public PfeifferPumpA100ReadPumpStatusHandler(PfeifferPumpA100 device)
|
||||
: base(device, "STA", null)
|
||||
{
|
||||
}
|
||||
public override bool HandleMessage(MessageBase msg, out bool handled)
|
||||
{
|
||||
if (base.HandleMessage(msg, out handled))
|
||||
{
|
||||
var result = msg as PfeifferPumpA100Message;
|
||||
|
||||
if(result.Data.Length != 68)
|
||||
{
|
||||
Device.NoteError("Invalid 'RunParameter'response, the length is not 68");
|
||||
}
|
||||
else
|
||||
{
|
||||
Device.NotePumpStatus(result.Data);
|
||||
}
|
||||
}
|
||||
return true;
|
||||
|
||||
}
|
||||
|
||||
}
|
||||
|
||||
public class PfeifferPumpA100ReadSetStateHandler : PfeifferPumpA100Handler
|
||||
{
|
||||
public PfeifferPumpA100ReadSetStateHandler(PfeifferPumpA100 device)
|
||||
: base(device, "LEV", null)
|
||||
{
|
||||
}
|
||||
public override bool HandleMessage(MessageBase msg, out bool handled)
|
||||
{
|
||||
if (base.HandleMessage(msg, out handled))
|
||||
{
|
||||
var result = msg as PfeifferPumpA100Message;
|
||||
|
||||
if (result.Data.Length != 136)
|
||||
{
|
||||
Device.NoteError("Invalid 'RunParameter'response, the length is not 67");
|
||||
}
|
||||
else
|
||||
{
|
||||
Device.NoteReadSetState(result.Data);
|
||||
}
|
||||
}
|
||||
return true;
|
||||
|
||||
}
|
||||
|
||||
}
|
||||
}
|
||||
Reference in New Issue