refactor: 将Framework库和RT、UI放在同一个解决方案中。
This commit is contained in:
+124
@@ -0,0 +1,124 @@
|
||||
using MECF.Framework.Common.Communications;
|
||||
|
||||
namespace MECF.Framework.RT.EquipmentLibrary.HardwareUnits.ThrottleValves.VAT
|
||||
{
|
||||
public abstract class VATS651Handler : HandlerBase
|
||||
{
|
||||
public VATS651 Device { get; }
|
||||
|
||||
public string _command;
|
||||
protected string _parameter;
|
||||
|
||||
|
||||
protected VATS651Handler(VATS651 device, string command, string parameter = null)
|
||||
: base(BuildMessage(command, parameter))
|
||||
{
|
||||
Device = device;
|
||||
_command = command;
|
||||
_parameter = parameter;
|
||||
Name = command;
|
||||
}
|
||||
|
||||
private static string _endLine = "\r\n";
|
||||
private static string BuildMessage( string command, string parameter)
|
||||
{
|
||||
string commandContent = parameter == null ? $"{command}" : $"{command}{parameter}";
|
||||
return commandContent + _endLine.ToString();
|
||||
}
|
||||
|
||||
public override bool HandleMessage(MessageBase msg, out bool transactionComplete)
|
||||
{
|
||||
VATS651Message response = msg as VATS651Message;
|
||||
ResponseMessage = msg;
|
||||
|
||||
if (response.IsError)
|
||||
{
|
||||
Device.NoteError(response.Data);
|
||||
transactionComplete = true;
|
||||
return false;
|
||||
}
|
||||
Device.NoteError(null);
|
||||
|
||||
if (response.IsAck)
|
||||
{
|
||||
SetState(EnumHandlerState.Acked);
|
||||
if(response.Data.IndexOf(_command)==0)
|
||||
{
|
||||
SetState(EnumHandlerState.Completed);
|
||||
transactionComplete = true;
|
||||
return true;
|
||||
}
|
||||
}
|
||||
transactionComplete = false;
|
||||
return false;
|
||||
}
|
||||
|
||||
}
|
||||
|
||||
public class VATS651RawCommandHandler : VATS651Handler
|
||||
{
|
||||
public VATS651RawCommandHandler(VATS651 device, string command, string parameter = null)
|
||||
: base(device, command, parameter)
|
||||
{
|
||||
}
|
||||
public override bool HandleMessage(MessageBase msg, out bool handled)
|
||||
{
|
||||
if(base.HandleMessage(msg, out handled))
|
||||
{
|
||||
var result = msg as VATS651Message;
|
||||
Device.NoteRawCommandInfo(_command, result.RawMessage);
|
||||
}
|
||||
return true;
|
||||
}
|
||||
}
|
||||
|
||||
public class VATS651SimpleActionHandler : VATS651Handler
|
||||
{
|
||||
public VATS651SimpleActionHandler(VATS651 device, string command, string parameter = null)
|
||||
: base(device, command, parameter)
|
||||
{
|
||||
}
|
||||
public override bool HandleMessage(MessageBase msg, out bool handled)
|
||||
{
|
||||
if (base.HandleMessage(msg, out handled))
|
||||
{
|
||||
Device.NoteActionCompleted(_command);
|
||||
}
|
||||
return true;
|
||||
}
|
||||
}
|
||||
public class VATS651SimpleSetHandler : VATS651Handler
|
||||
{
|
||||
public VATS651SimpleSetHandler(VATS651 device, string command, string parameter = null)
|
||||
: base(device, command, parameter)
|
||||
{
|
||||
}
|
||||
public override bool HandleMessage(MessageBase msg, out bool handled)
|
||||
{
|
||||
if (base.HandleMessage(msg, out handled))
|
||||
{
|
||||
Device.NoteSetCompleted(_command, _parameter);
|
||||
}
|
||||
return true;
|
||||
}
|
||||
}
|
||||
public class VATS651SimpleQueryHandler : VATS651Handler
|
||||
{
|
||||
public VATS651SimpleQueryHandler(VATS651 device, string command, string parameter = null)
|
||||
: base(device, command, parameter)
|
||||
{
|
||||
}
|
||||
public override bool HandleMessage(MessageBase msg, out bool handled)
|
||||
{
|
||||
if (base.HandleMessage(msg, out handled))
|
||||
{
|
||||
var vatMsg = msg as VATS651Message;
|
||||
string result = vatMsg.Data.Substring(_command.Length);
|
||||
Device.NoteQueryResult(_command, result);
|
||||
}
|
||||
return true;
|
||||
}
|
||||
|
||||
}
|
||||
|
||||
}
|
||||