using MECF.Framework.UI.Client.RecipeEditorLib.DGExtension.CustomColumn;
|
||
using System;
|
||
using System.Collections.Generic;
|
||
using System.Linq;
|
||
using System.Windows;
|
||
|
||
namespace MECF.Framework.UI.Client.RecipeEditorLib.RecipeModel.Params
|
||
{
|
||
public class FlowModeParam : ComboxParam
|
||
{
|
||
#region Variables
|
||
|
||
public enum FlowModeEnum
|
||
{
|
||
Vent,
|
||
Purge,
|
||
Run
|
||
}
|
||
|
||
#endregion
|
||
|
||
#region Constructors
|
||
|
||
public FlowModeParam(IEnumerable<ComboxColumn.Option> options, string controlName, string initValue, string defaultValue) :
|
||
base(options, controlName, initValue, defaultValue)
|
||
{
|
||
}
|
||
|
||
#endregion
|
||
|
||
#region Properties
|
||
|
||
public override ComboxColumn.Option Value
|
||
{
|
||
get => _value;
|
||
set
|
||
{
|
||
var isSwitchToVent = false;
|
||
if (value.Equals(FlowModeEnum.Purge))
|
||
{
|
||
if (Previous is FlowModeParam pp)
|
||
{
|
||
if (pp.Value.Equals(FlowModeEnum.Run))
|
||
{
|
||
isSwitchToVent = true;
|
||
}
|
||
}
|
||
|
||
if (Next is FlowModeParam np)
|
||
{
|
||
if (np.Value.Equals(FlowModeEnum.Run))
|
||
{
|
||
isSwitchToVent = true;
|
||
}
|
||
}
|
||
}
|
||
else if (value.Equals(FlowModeEnum.Run))
|
||
{
|
||
if (Previous is FlowModeParam pp)
|
||
{
|
||
if (pp.Value.Equals(FlowModeEnum.Purge))
|
||
{
|
||
isSwitchToVent = true;
|
||
}
|
||
}
|
||
|
||
if (Next is FlowModeParam np)
|
||
{
|
||
if (np.Value.Equals(FlowModeEnum.Purge))
|
||
{
|
||
isSwitchToVent = true;
|
||
}
|
||
}
|
||
}
|
||
|
||
if (isSwitchToVent)
|
||
MessageBox.Show("Flow mode cannot be switched directly between 'Purge' and 'Run'.", "Error",
|
||
MessageBoxButton.OK, MessageBoxImage.Error);
|
||
|
||
_value = isSwitchToVent
|
||
? Options.FirstOrDefault(x => x.Equals(FlowModeEnum.Vent)) ?? Options.First()
|
||
: value;
|
||
|
||
ColumnPermChangedCallback?.Invoke(this);
|
||
_isSaved = _value.Equals(_valueSnapshot);
|
||
|
||
OnPropertyChanged();
|
||
OnPropertyChanged(nameof(IsSaved));
|
||
}
|
||
}
|
||
|
||
#endregion
|
||
|
||
#region Methods
|
||
|
||
private void InnerValidate()
|
||
{
|
||
// 判断Flow Mode是否直接在Purge和Run之间切换。
|
||
|
||
var currentStepOption = Value;
|
||
var flowModeValid = true;
|
||
|
||
if (Previous != null)
|
||
{
|
||
var previousStepOption = ((ComboxParam)Previous).Value;
|
||
if ((previousStepOption.Equals(FlowModeEnum.Purge) && currentStepOption.Equals(FlowModeEnum.Run))
|
||
|| (previousStepOption.Equals(FlowModeEnum.Run) && currentStepOption.Equals(FlowModeEnum.Purge)))
|
||
{
|
||
flowModeValid = false;
|
||
}
|
||
}
|
||
|
||
if (Next != null)
|
||
{
|
||
var nextStepOption = ((ComboxParam)Next).Value;
|
||
if ((nextStepOption.Equals(FlowModeEnum.Purge) && currentStepOption.Equals(FlowModeEnum.Run))
|
||
|| (nextStepOption.Equals(FlowModeEnum.Run) && currentStepOption.Equals(FlowModeEnum.Purge)))
|
||
{
|
||
flowModeValid = false;
|
||
}
|
||
}
|
||
|
||
IsValid = flowModeValid;
|
||
ValidationError = !flowModeValid
|
||
? "Flow mode cannot be switched directly between 'Purge' and 'Run'"
|
||
: null;
|
||
}
|
||
|
||
public override void Validate()
|
||
{
|
||
var linkedList = Flatten();
|
||
|
||
foreach (var param in linkedList)
|
||
{
|
||
if(param is FlowModeParam p)
|
||
p.InnerValidate();
|
||
}
|
||
|
||
//TODO 如果当前参数是TMA或TCS,当设备未安装,流量模式必须为Purge
|
||
//Issue TCS没有对应的系统参数;TMA要区分PM腔,但Recipe不分PM腔,此处不好判断
|
||
if (ControlName == RecipeControlNames.TMA_FLOW_MODE)
|
||
{
|
||
|
||
}
|
||
|
||
if (ControlName == RecipeControlNames.TCS_FLOW_MODE)
|
||
{
|
||
|
||
}
|
||
}
|
||
|
||
#endregion
|
||
}
|
||
}
|